Superstructure rates
- Items
- 97
- Lowest rate
- ₹49.17
- Highest rate
- ₹1,19,958.60
- Effective from
- 2024-08-14
Superstructure rates in the Puducherry Puducherry Schedule of Rates 2024-25 run from ₹49.17 to ₹1,19,958.60. Transcribed from Puducherry PWD — Puducherry Schedule of Rates 2024-25, Puducherry region. Base PDF only; PWD has since issued Correction Slip-3 (22 January 2025) for all four regions, so some rates here may be superseded.. For reference only: verify against the official source before pricing a bid.
97 items. Scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| 14.2 | Supplying, fitting and placing Thermo Mechanical Treated bars reinforcement in superstructure complete as per drawing and technical specifications | Tonne | 1,19,958.60 |
| 14.4 | Providing and laying cement concrete wearing coat M30 grade with a minimum cement content 405 kg / cum including reinforcement complete as per drawing and technical specification | Cum | 17,520.29 |
| 14.6 | Construction of precast RCC railing of M30 grade with a minimum cement content 407 kg / cum, aggregate size not exceeding 12mm, true to line and grade, tolerance of vertical RCC post not to exceed I in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications | Rmt | 2,873.48 |
| 14.7 | Construction of RCC railing of M30 grade with a minimum cement content 407 kg / cum cast- in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications | Rmt | 3,218.30 |
| 14.9 | Drainage spouts complete as per drawing and Technical Specifications. (Including 5 percent cost of material and labour for electrodes,cutting gas, sealant, anticorrosive bituminous paint, mild steel grating etc.) | Each | 2,141.04 |
| 14.10 | PCC M15 with a minimum cement content 275 kg / cum grade levelling course below approch slab complete as per drawing and technical specifications | Cum | 7,267.14 |
| 14.11A | Reinforced cement concrete M30 grade with a minimum cement content 407 kg / cum approach slab including reinforcement and formwork complete as per drawing and technical specifications - Using concrete mixer | Cum | 14,839.60 |
| 14.11B | Reinforced cement concrete M30 grade with a minimum cement content 407 kg / cum approach slab including reinforcement and formwork complete as per drawing and technical specifications - Using batching plant, transit mixer and concrete pump | Cum | 13,203.20 |
| 14.16 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm | Sqm | 316.01 |
| 14.1A.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using concrete mixer - for solid slab superstructure - height upto 5m including all machineries and formwork etc | Cum | 9,358.53 |
| 14.1B.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer - for solid slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 9,949.16 |
| 14.1C.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer - for solid slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 10,126.54 |
| 14.2A.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using batching plant, transit mixer and concrete pump- for solid slab superstructure -for height upto 5m- including all mahineries and formwork,etc | Cum | 7,694.01 |
| 14.2B.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant,transit mixer an concrete pump -for solid slab superstructure - height upto 5m- including all machineries and formwork, etc | Cum | 8,296.17 |
| 14.2C.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height upto 5m- including all machineries and formwork, etc | Cum | 8,391.49 |
| 14.18.1 | Providing and fixing 2mm thick corrugated copper plate in expansion joint complete as per drawing and technical specifications | Rmt | 1,804.28 |
| 14.1A.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341 kg / cum - Using concrete mixer - for T-beam & slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 9,748.47 |
| 14.1B.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer and electric gen set - for T-beam & slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 10,363.71 |
| 14.1C.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer - forT-beam & slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 10,548.48 |
| 14.1D.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer - for solid slab superstructure - height upto 5m including all machineries and formwork, etc | Cum | 10,111.30 |
| 14.1E.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer - for solid slab superstructure- height upto 5m including all machineries and formwork, etc | Cum | 11,144.48 |
| 14.1F.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height upto 5m- including all machineries and formwork, etc | Cum | 9,330.19 |
| 14.1G.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M50 with a minimum cement content 490 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height upto 5m-including all machineries and formwork, etc | Cum | 11,184.81 |
| 14.1H.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M55 with a minimum cement content 529 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height upto 5 m-including all machineries and formwork, etc | Cum | 11,696.17 |
| 14.2A.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using batching plant, transit mixer and concrete pump- for T-beam & slab superstructure -for height upto 5m- including all machineries and formwork | Cum | 8,014.59 |
| 14.2B.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant, transit mixer and concrete pump - for T-beam & slab superstructure - height upto 5m- including all machineries and formwork,etc | Cum | 8,641.85 |
| 14.2C.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant -for T-beam & slab superstructure - height upto 5m | Cum | 8,741.13 |
| 14.2D.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height upto 5m- including all machineries and formwork,etc | Cum | 8,389.49 |
| 14.2E.1.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure- height upto 5m-including all machineries and formwork,etc | Cum | 9,091.64 |
| 14.1D.1.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for T-beam & slab superstructure - height upto 5m-including all machineries and formwork,etc | Cum | 10,539.75 |
| 14.1E.1.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer -for T-beam & slab superstructure- height upto 5m-including all machineries and formwork,etc | Cum | 11,608.84 |
| 14.1F.1.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for I - beam and slab including launching of precast girders by launching truss upto 40m span - height upto 5m-including all machineries and formwork, etc | Cum | 9,732.35 |
| 14.2D.1.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump -for T-beam & slab superstructure - height upto 5m-including all machineries and formwork,etc | Cum | 8,744.98 |
| 14.2E.1.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for I - beam and slab superstructure including launching of precast girders by launching truss upto 40m span- height upto 5m-including all machineries and formwork,etc | Cum | 9,476.88 |
| 14.1D.1.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for box girder and balanced cantilever - height upto 5m-including all machineries and formwork,etc | Cum | 11,825.08 |
| 14.1F.1.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height upto 5m-including all machineries and formwork, etc | Cum | 10,938.84 |
| 14.2D.1.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump -for box girder and balanced cantilever- height upto 5m-including all machineries and formwork,etc | Cum | 9,811.44 |
| 14.2E.1.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in-situ box girder, segmental construction and balanced cantilever - height upto 5m- including all machineries and formwork, etc | Cum | 10,632.59 |
| 14.1A.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341 kg / cum - Using concrete mixer -for solid slab superstructure - for height above 5m upto 10m-including all machineries and formwork etc | Cum | 9,748.47 |
| 14.1B.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer -for solid slab superstructure - height above 5m and upto 10m including all machineries and formwork, etc | Cum | 10,363.71 |
| 14.1C.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer -for solid slab superstructure - height above 5m to 10m-including all machineries and formwork, etc | Cum | 10,548.48 |
| 14.2A.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using batching plant, transit mixer and concrete pump- for solid slab superstructure -for height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 8,014.59 |
| 14.2B.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant, transit mixer and concrete pump- for solid slab superstructure - height above 5m and upto 10m- including all machineries and formwork, etc | Cum | 8,641.85 |
| 14.2C.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant,transit mixer and concrete pump - for solid slab superstructure - height above 5m to 10m- including all machineries and formwork, etc | Cum | 8,741.13 |
| 14.18.2 | Providing and fixing 20mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications | Rmt | 114.18 |
| 14.1A.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341 kg / cum - Using concrete mixer -for T-beam & slab superstructure -for height above 5m upto 10m-including all machineries and formwork etc | Cum | 10,138.41 |
| 14.1B.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer -for T-beam & slab superstructure - height above 5m and upto 10m- including all machineries and formwork, etc | Cum | 10,778.25 |
| 14.1C.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer -forT-beam & slab superstructure - height above 5m to 10m-including all machineries and formwork,etc | Cum | 10,970.42 |
| 14.1D.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for solid slab superstructure - height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 10,539.75 |
| 14.1E.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer -for solid slab superstructure- height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 11,608.84 |
| 14.1F.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height above 5m and upto 10m- including all machineries and formwork, etc | Cum | 9,732.35 |
| 14.1G.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M50 with a minimum cement content 490 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 5m to 10m-including all machineries and formwork, etc | Cum | 12,013.31 |
| 14.1H.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M55 with a minimum cement content 529 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 5m to 10m- including all machineries and formwork, etc | Cum | 12,495.25 |
| 14.2A.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341 kg / cum - Using batching plant, transit mixer and concrete pump- for T-beam & slab superstructure -for height above 5m and upto 10m-including all machineries and formwork, etc | Cum | 8,335.17 |
| 14.2B.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant, transit mixer and concrete pump - for T-beam & slab superstructure - height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 8,987.52 |
| 14.2C.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant, transit mixer and concrete pump - for T-beam & slab superstructure - height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 9,090.78 |
| 14.2D.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height above 5m to 10m-including all machineries and formwork,etc | Cum | 8,744.98 |
| 14.2E.2.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant,transit mixer and concrete pump - for solid slab superstructure- height above 5m and upto 10m- including all machineries and formwork, etc | Cum | 8,928.47 |
| 14.1D.2.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for T-beam & slab superstructure - height above 5m to 10m-including all machineries and formwork,etc | Cum | 10,968.19 |
| 14.1E.2.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer -for T-beam & slab superstructure- height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 12,073.19 |
| 14.1F.2.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant,transit mixer and concrete pump - for I - beam and slab including launching of precast girders by launching truss upto 40m span - height above 5m and upto 10m- including all machineries and formwork, etc | Cum | 10,134.52 |
| 14.2D.2.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant,transit mixer and concrete pump -for T-beam & slab superstructure - height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 9,100.47 |
| 14.2E.2.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for I - beam and slab superstructure including launching of precast girders by launching truss upto 40m span- height above 5m and upto 10m- including all machineries and formwork,etc | Cum | 9,862.12 |
| 14.1D.2.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for box girder and balanced cantilever - height above 5m and upto 10m- including all machineries and formwork,etc | Cum | 12,681.97 |
| 14.1F.2.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 5m and upto 10m-including all machineries and formwork, etc | Cum | 11,743.17 |
| 14.2D.2.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump -for box girder and balanced cantilever- height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 10,522.42 |
| 14.2E.2.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in-situ box girder, segmental construction and balanced cantilever - height above 5m and upto 10m-including all machineries and formwork,etc | Cum | 11,403.07 |
| 14.1A.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using concrete mixer -for solid slab superstructure - for height above 10m-including all machineries and formwork etc | Cum | 10,138.41 |
| 14.1B.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer -for solid slab superstructure - height above10m- including all machineries and formwork,etc | Cum | 10,778.25 |
| 14.1C.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer -for solid slab superstructure - height above 10m-including all machineries and formwork,etc | Cum | 10,970.42 |
| 14.2A.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure -for height above 10m | Cum | 8,335.17 |
| 14.2B.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height above 10m- including all machineries and formwork,etc | Cum | 8,987.52 |
| 14.2C.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height above 10m-including all machineries and formwork, etc | Cum | 9,090.78 |
| 14.18.3 | Providing and fixing in position 20mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10m to cater for a horizontal movement upto 20mm, covered with sealant complete as per drawing and technical specifications | Rmt | 49.17 |
| 14.1A.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341 kg / cum - Using concrete mixer -for T-beam & slab superstructure -for height above 10m-including all machineries and formwork etc | Cum | 10,528.34 |
| 14.1B.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 399 kg / cum - Using concrete mixer -for T-beam & slab superstructure - height above 10m- including all machineries and formwork, etc | Cum | 11,192.80 |
| 14.1C.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using concrete mixer -forT-beam & slab superstructure - height above10m-including all machineries and formwork,etc | Cum | 11,392.35 |
| 14.1D.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for solid slab superstructure - height above 10m-including all machineries and formwork,etc | Cum | 10,968.19 |
| 14.1E.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer -for solid slab superstructure- height above 10m-including all machineries and formwork,etc | Cum | 12,073.19 |
| 14.1F.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for solid slab superstructure - height above 10m-including all machineries and formwork, etc | Cum | 9,804.14 |
| 14.1G.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M50 with a minimum cement content 490 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 10m-including all machineries and formwork, etc | Cum | 12,841.82 |
| 14.1H.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M55 with a minimum cement content 529 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 10m-including all machineries and formwork, etc | Cum | 13,428.93 |
| 14.2A.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M20 with a minimum cement content 341kg / cum - Using batching plant, transit mixer and concrete pump- for T-beam & slab superstructure -for height above 10m- including all machineries and formwork etc | Cum | 8,655.76 |
| 14.2B.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M25 with a minimum cement content 400 kg / cum - Using batching plant, transit mixer and concrete pump - for T-beam & slab superstructure - height above 10m - including all machineries and formwork, etc | Cum | 8,958.25 |
| 14.2C.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M30 with a minimum cement content 407 kg / cum - Using batching plant, transit mixer and concrete pump - for T-beam & slab superstructure - height above 10m- including all machineries and formwork, etc | Cum | 9,440.42 |
| 14.2D.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump, etc., - for solid slab superstructure - height above 10m-including all machineries and formwork,etc | Cum | 9,100.47 |
| 14.2E.3.1 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant -for solid slab superstructure- height above 10m | Cum | 9,862.12 |
| 14.1D.3.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for T-beam & slab superstructure - height above 10m-including all machineries and formwork,etc | Cum | 11,396.64 |
| 14.1E.3.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using concrete mixer -for T-beam & slab superstructure- height above 10m-including all machineries and formwork,etc | Cum | 12,537.54 |
| 14.1F.3.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant, transit mixer and concrete pump - for I - beam and slab including launching of precast girders by launching truss upto 40m span - height above 10m-including all machineries and formwork, etc | Cum | 10,536.68 |
| 14.2D.3.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump -for T-beam & slab superstructure - height above 10m- including all machineries and formwork,etc | Cum | 9,455.96 |
| 14.2E.3.2 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for I - beam and slab superstructure including launching of precast girders by launching truss upto 40m span- height above 10m- including all machineries and formwork,etc | Cum | 10,247.36 |
| 14.1D.3.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using concrete mixer -for box girder and balanced cantilever - height above10m-including all machineries and formwork,etc | Cum | 13,538.86 |
| 14.1F.3.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M45 with a minimum cement content 465 kg / cum - Using batching plant,transit mixer and concrete pump - for cast - in - situ box girder, segmental construction and balanced cantilever - height above 10m-including all machineries and formwork, etc | Cum | 12,547.50 |
| 14.2D.3.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - RCC grade M35 / PSC grade M35 with a minimum cement content 422 kg / cum - Using batching plant, transit mixer and concrete pump -for box girder and balanced cantilever- height above 10m-including all machineries and formwork,etc | Cum | 11,233.39 |
| 14.2E.3.3 | Furnishing and placing reinforced cement concrete in superstructure as per drawing and technical specifications - PSC grade M40 with a minimum cement content 430 kg / cum - Using batching plant, transit mixer and concrete pump - for cast - in-situ box girder, segmental construction and balanced cantilever - height above 10m- including all machineries and formwork,etc | Cum | 12,173.55 |
| 14.18.4 | Providing and filling joint sealing compound as per drawings and technical specification with coarse fine aggregate and 6 percent bitumen by weight | Rmt | 72.34 |
- ISSUED BY
- Puducherry PWD
- EFFECTIVE
- 2024-08-14From the Puducherry PWD website, which lists this schedule as "PSR 2024-25 (with effect from 14th August 2024 onwards)". The PDF itself prints no date anywhere in its 1,216 pages.
- RETRIEVED
- 2026-07-29
Other chapters in this schedule
- Earth Work70
- Concrete Work72
- Reinforced Concrete Work131
- Brick Work57
- Stone Work50
- Cladding Work71
- Wood and PVC Work493
- Steel Work52
- Flooring91
- Roofing135
- Finishing114
- Repairs To Buildings108
SHOW ALL 44 CHAPTERS
- Dismantling And Demolishing85
- Miscellaneous Building Work25
- Sanitary Installations226
- Water Supply708
- Drainage135
- Pile Work31
- Aluminium Work41
- Water Proofing27
- Rain Water Harvesting & TubeWells37
- Conservation of Heritage Buildings7
- Structural Glazing Aluminium Composite Panel5
- New Technologies and Materials196
- Irrigation50
- Water Supply (Public Health)1012
- Sewerage (Public Health)213
- Miscellaneous (Public Health)71
- OHT (Works)8
- Subsoil Exploration7
- Energy Conservation Building Code137
- Site Clearance and Dismantling44
- Earth Work, Erosion Control and Drainages40
- Granular Sub-base63
- Base & Bituminous Construction26
- Traffic Signs,Markings & Other Road Appurtenances41
- Pipe Culverts5
- Maintenance of Roads13
- Horticulture25
- Foundation106
- Substructure54
- River Training and Protection Works10
- Repair and Rehabilitation12
- PMGSY -Works25
Pricing superstructure against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index and catching where rates have moved since the base edition takes time and is easy to get wrong. We can do it for you: send the tender and we return a priced BOQ on the applicable schedule, with rate build-ups and an engineer's sign-off.