Puducherry SOR 2024-25

Energy Conservation Building Code rates

137 energy conservation building code items from the Puducherry PWD, effective 2024-08-14.

Energy Conservation Building Code rates in the Puducherry Puducherry Schedule of Rates 2024-25 run from ₹245.00 to ₹2,90,460.00. Transcribed from Puducherry PWD — Puducherry Schedule of Rates 2024-25, Puducherry region. Base PDF only; PWD has since issued Correction Slip-3 (22 January 2025) for all four regions, so some rates here may be superseded.. Reference only — verify against the official source before pricing a bid.

137 items — scroll the table to browse

DescriptionUnit
36.1Providing and fixing polyurethane foam (PUF) slab 40mm thick average with PU slab density 36+/-2 kg/m³ for external wall insulation including necessary polymerized plaster reinforced with glass fibre mesh, epoxy based bonding adhesive etc., completeSqm1,462.00
36.2Providing and fixing cast in situ polyurethane foam (PUF) spray 40mm thick average with PU foam spray density 35+/-5 kg/m³ for external wall insulation including necessary adhesive etc., completeSqm1,239.00
36.3Providing and fixing cast in situ polyurethane foam (PUF) spray 50mm thick average with PU foam spray density 35+/-5 kg/m³ for external wall insulation including necessary adhesive etc., completeSqm1,270.00
36.4Providing and fixing Extruded Polystyrene (XPS) thermal insulating boards 25mm thick average for external wall insulation including necessary fasteners etc., completeSqm526.00
36.5Providing and fixing Extruded Polystyrene (XPS) thermal insulating boards 50mm thick average for external wall insulation including necessary fasteners etc., completeSqm806.00
36.6Providing and fixing Extruded Polystyrene (XPS) thermal insulating boards 75mm thick average for external wall insulation including necessary fasteners etc., completeSqm1,123.00
36.7Providing and fixing Extruded Polystyrene (XPS) thermal insulating boards 100mm thick average for external wall insulation including necessary fasteners etc., completeSqm1,440.00
36.8Providing and fixing polyurethane foam (PUF) spray 40mm thick average PU foam spray having density 35+/-5 kg/m3 density for insulatiom of cavity wall with including necessary fasteners etc., completeSqm647.00
36.9Providing and fixing polyurethane foam (PUF) spray 50mm thick average PU foam spray having density 35+/-5 kg/m3 density for insulatiom of cavity wall with including necessary fasteners etcSqm922.00
36.10Providing and fixing glass wool slab 12mm thick resin bonded slab with density 48kg/m3 for insulation of cavity wall, fixed using GI wire 200 SWG, GI chicken mesh 12.50mm x 24 SWG including necessary criss-cross GI wire mesh,raw plugs, adhesive etc., completeSqm593.00
36.11Providing and fixing glass wool slab 25mm thick resin bonded slab with density 48kg/m3 for insulation of cavity wall, fixed using GI wire 200 SWG, GI chicken mesh 12.50mm x 24 SWG including necessary criss-cross GI wire mesh,raw plugs, adhesive etc., completeSqm725.00
36.12Providing and fixing glass wool slab 50mm thick resin bonded slab with density 48kg/m3 for insulation of cavity wall, fixed using GI wire 200 SWG, GI chicken mesh 12.50mm x 24 SWG including necessary criss-cross GI wire mesh,raw plugs, adhesive etc., completeSqm840.00
36.13Providing and fixing rock wool slab 25mm thick resin bonded rock wool slab having density 36+/-5 kg/m3 for insulation of cavity wall with including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm512.00
36.14Providing and fixing rock wool slab 40mm thick resin bonded rock wool slab having density 36+/-5 kg/cum for insulation of cavity wall with including necessary criss-cross GI wire, mesh, raw plugs, adhesive etc., completeSqm541.00
36.15Providing and fixing rock wool slab 50mm thick resin bonded rock wool slab having density 36+/-5 kg/m3 for insulation of cavity wall with including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm559.00
36.16Providing and fixing rock wool slab 65mm thick resin bonded rock wool slab having density 36+/-5 kg/m3 for insulation of cavity wall with including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm591.00
36.17Providing and fixing rock wool slab 75mm thick resin bonded rock wool slab having density 36+/-5 kg/m3 for insulation of cavity wall with including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm611.00
36.18Providing and fixing rock wool slab 100mm thick resin bonded rock wool slab having density 36+/-5 kg/m3 for insulation of cavity wall with including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm879.00
36.19Providing and fixing extruded polystyrene (XPS) 50mm thick thermal insulating boards having density 36+/-5 kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,066.00
36.20Providing and fixing extruded polystyrene (XPS) 60mm thick thermal insulating boards having density 36+/-5 kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,084.00
36.21Providing and fixing extruded polystyrene (XPS) 70mm thick thermal insulating boards having density 36+/-5 kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,384.00
36.22Providing and fixing extruded polystyrene (XPS) 25mm thick thermal insulating boards having density 32kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm763.00
36.23Providing and fixing extruded polystyrene (XPS) 50mm thick thermal insulating boards having density 32kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,066.00
36.24Providing and fixing extruded polystyrene (XPS) 75mm thick thermal insulating boards having density 32kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,407.00
36.25Providing and fixing extruded polystyrene (XPS) 100mm thick thermal insulating boards having density 32kg/m3 for insulation of cavity wall including necessary criss-cross GI wire, mesh,raw plugs, adhesive etc., completeSqm1,749.00
36.26Providing and fixing polyurethane foam (PUF) slab 40mm thick average with PU slab density 36+/-2 kg/m³ insulation for over deck covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm1,333.00
36.27Providing and fixing polyurethane foam (PUF) slab 50mm thick average with PU slab density 36+/-2 kg/m³ insulation for over deck covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm1,635.00
36.28Providing and fixing polyurethane foam (PUF) slab 60mm thick average with PU slab density 36+/-2 kg/m³ insulation for over deck covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm1,928.00
36.29Providing and fixing polyurethane foam (PUF) slab 70mm thick average with PU slab density 36+/-2 kg/m³ insulation for over deck covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm2,214.00
36.30Providing and fixing Over deck insulation with cast insitu polyurethane foam (PUF) spray 40mm thick average with PU foam spray including necessary fasteners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20 grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm1,222.00
36.31Providing and fixing Over deck insulation with cast insitu polyurethane foam (PUF) spray 50mm thick average with PU foam spray including necessary fasteners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20 grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm1,401.00
36.32Providing and fixing Over deck insulation with cast insitu polyurethane foam (PUF) spray 60mm thick average with PU foam spray including necessary fasteners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20 grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., completeSqm2,064.00
36.33Providing and fixing Over deck insulation with cast insitu polyurethane foam (PUF) spray 70mm thick average with PU foam spray including necessary fasteners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20 grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slabs, epoxy bases bonding adhesive etc., complete (The cost of concrete to be paid separately)Sqm2,453.00
36.34Providing and fixing expanded polystyrene (EPS) 50mm thick average for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm862.00
36.35Providing and fixing expanded polystyrene (EPS) 70mm thick average for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm940.00
36.36Providing and fixing expanded polystyrene (EPS) 90mm thick average for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,015.00
36.37Providing and fixing expanded polystyrene (EPS) 110mm thick average for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,089.00
36.38Providing and fixing expanded polystyrene (EPS) 120mm thick average for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,127.00
36.39Providing and fixing expanded polystyrene (EPS) 30mm thick with density 20kg/m3 for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm850.00
36.40Providing and fixing expanded polystyrene (EPS) 40mm thick with density 20kg/m3 for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm860.00
36.41Providing and fixing expanded polystyrene (EPS) 50mm thick with density 20kg/m3 for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm865.00
36.42Providing and fixing expanded polystyrene (EPS) 75mm thick with density 20kg/m3 for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm940.00
36.43Providing and fixing expanded polystyrene (EPS) 100mm thick with density 20kg/m3 for under deck thermal insulation including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,037.00
36.44Providing and fixing expanded polystyrene (50 mm thick) with aluminium strips at every 600mm c/c over existing false ceiling for thermal insulation of roofing including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm648.00
36.45Providing and fixing expanded polystyrene (70 mm thick) with aluminium strips at every 600mm c/c over existing false ceiling for thermal insulation of roofing including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm745.00
36.46Providing and fixing expanded polystyrene (90 mm thick) with aluminium strips at every 600mm c/c over existing false ceiling for thermal insulation of roofing including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm813.00
36.47Providing and fixing expanded polystyrene (110 mm thick) with aluminium strips at every 600mm c/c over existing false ceiling for thermal insulation of roofing including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm910.00
36.48Providing and fixing expanded polystyrene (120 mm thick) with aluminium strips at every 600mm c/c over existing false ceiling for thermal insulation of roofing including necessary fasteners etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm961.00
36.49Providing and fixing expanded polystyrene (50 mm thick) for over deck thermal insulation of roofing including necessary fastrners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, epoxy based bonding adhesive etc., completeSqm685.00
36.50Providing and fixing expanded polystyrene (70 mm thick) for over deck thermal insulation of roofing including necessary fastrners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, epoxy based bonding adhesive etc., completeSqm781.00
36.51Providing and fixing expanded polystyrene (90 mm thick) for over deck thermal insulation of roofing including necessary fastrners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, epoxy based bonding adhesive etc., completeSqm847.00
36.52Providing and fixing expanded polystyrene (110 mm thick) for over deck thermal insulation of roofing including necessary fastrners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, epoxy based bonding adhesive etc., completeSqm944.00
36.53Providing and fixing expanded polystyrene (120 mm thick) for over deck thermal insulation of roofing including necessary fastrners etc., complete covered with two layers of 40mm thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) smooth finished with floating coat of neat cement, including necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, epoxy based bonding adhesive etc., completeSqm994.00
36.54Providing and fixing 12mm resin bonded glass wool slab having density 48 kg/ cum for over deck inssulation of roofing with glass wool including necessary fasteners, GI wire & mesh etc., completeSqm1,059.00
36.55Providing and fixing 25mm resin bonded glass wool slab having density 48 kg/ cum for over deck inssulation of roofing with glass wool including necessary fasteners, GI wire & mesh etc., completeSqm1,191.00
36.56Providing and fixing 50mm resin bonded glass wool slab having density 48 kg/ cum for over deck inssulation of roofing with glass wool including necessary fasteners, GI wire & mesh etc., completeSqm1,306.00
36.57Poviding and fixing Rock wool 25mm resin bonded rock wool slab having density 48 kg/ cum for over deck insulation of roofing including necessary fastners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm738.00
36.58Poviding and fixing Rock wool 40mm resin bonded rock wool slab having density 48 kg/ cum for over deck insulation of roofing including necessary fastners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm766.00
36.59Poviding and fixing Rock wool 50mm resin bonded rock wool slab having density 48 kg/ cum for over deck insulation of roofing including necessary fastners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm783.00
36.61Poviding and fixing Rock wool 75mm resin bonded rock wool slab having density 48 kg/ cum for over deck insulation of roofing including necessary fastners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm833.00
36.62Poviding and fixing Rock wool 100mm resin bonded rock wool slab having density 48 kg/ cum for over deck insulation of roofing including necessary fastners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm884.00
36.63Providing and fixing glass wool 25mm resin bonded glass wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,248.00
36.64Providing and fixing glass wool 50mm resin bonded glass wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., complete (excluding cost of screed concrete which is to be measured and paid seperately)Sqm1,359.00
36.65Providing and fixing Rock wool 25mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., completeSqm736.00
36.66Providing and fixing Rock wool 40mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., completeSqm764.00
36.67Providing and fixing Rock wool 50mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., completeSqm780.00
36.68Providing and fixing Rock wool 65mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., complete with all lead and lift, transportation charges, loading unloading charges all taxes, cost of all materials, labour, Usage Charges of machinery, scaffolding etc., completeSqm810.00
36.69Providing and fixing Rock wool 75mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., complete with all lead and lift, transportation charges, loading unloading charges all taxes, cost of all materials, labour, Usage Charges of machinery, scaffolding etc., completeSqm829.00
36.70Providing and fixing Rock wool 100mm resin bonded rock wool slab having density 48 kg/cum for under deck insulation of roofing including necessary fasteners, GI wire & mesh etc., complete with all lead and lift, transportation charges, loading unloading charges all taxes, cost of all materials, labour, Usage Charges of machinery, scaffolding etc., completeSqm880.00
36.71Providing and fixing Ceramic Cool tiles of size 254x254x15mm thickness thermal insulation properties as per GRIHA guidelines with satisfactory SRI > 70% & R value laid on 12mm insulated Mortar mixusing heat proof sand completeSqm1,146.00
36.72Providing and supplying Non load bearing bricks of size 200/150/100 mm thickness for infill masonry with excellent thermal and sound insulation with density 700-800 kg/cum and compressive strength > 3.5N/sq.mm & water absorption not greater than 15% & U value 1 w/sqm K laid with Cement Mortar 1:6 conforming to building envelope as per GRIHA certification etc completeSqm742.00
36.73Providing and supplying Non load bearing bricks of size 200/150/100 mm thickness for infill masonry with excellent thermal and sound insulation with density 750-850kg/cum and compressive strength > 7.0 N/sq.mm & water absorption not greater than 15% & U value 1.30 W/sqm K laid with cement Mortar 1:6 conforming to Building envelope as per GRIHA certification etc completeSqm793.00
36.74Poviding and fixing double glazed hermetically sealed glazing in aluminium windows, Ventilators and partition etc. with 6mm thick clear float glass both side, having 12mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complte including cost of materials, labour, usage sharges of machinery complete as per specifications and as per directions of the Engineer-in-chargeSqm4,345.00
36.75Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 600W/580WEach2,90,460.00
36.76Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 300 W/ 280 WEach1,40,100.00
36.77Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 250 WEach1,20,200.00
36.78Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 140 WEach75,016.00
36.79Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 130 WEach68,389.00
36.80Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 110 W/115 WEach57,050.00
36.81Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 90 WEach52,460.00
36.82Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 75 WEach49,010.00
36.83Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 55 WEach43,007.00
36.84Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 45 W/40 WEach37,240.00
36.85Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for façade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producting dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at linevoltage without any separate power supply from 100-270 V AC, 50 Hz with power factor >0.9. Fixture shall be suitable to operate at an ambient temperature range of -10 degree C to + 50 degree C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc.as required - 30 WEach20,019.00
36.86Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Façade Lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10 degree C to +50degree C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required- 80 WEach56,720.00
36.87Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Façade Lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10 degree C to +50degree C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required- 70 WEach54,100.00
36.88Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Façade Lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10 degree C to +50degree C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required- 60 WEach46,036.00
36.89Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Façade Lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10 degree C to +50degree C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required- 40 WEach39,050.00
36.90Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Façade Lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of -10 degree C to +50degree C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50 degree C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required- 25 WEach23,130.00
36.91Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3nos. Blades, 30 cm long down rod, 2nos. Canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C (max), insualtion resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as requiredEach2,730.00
36.93Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 0.8TREach27,381.00
36.94Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 1 TREach29,137.00
36.95Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 1.2 TREach29,488.00
36.96Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 1.6 TREach30,204.00
36.97Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 2 TREach30,801.00
36.98Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 2.4 TREach31,453.00
36.99Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 2.8 TREach32,015.00
36.100Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 3.2 TREach32,787.00
36.101Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 3.6 TREach33,209.00
36.102Supply, Installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +_ 10%, 50Hz AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The colling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature - 4 TREach33,981.00
36.103Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-0.6 TREach18,730.00
36.104Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-0.8 TREach19,312.00
36.105Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-1 TREach19,700.00
36.106Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-1.3 TREach21,176.00
36.107Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-1.45 TREach21,315.00
36.108Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-1.65 TREach21,746.00
36.109Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V +_10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature-2 TREach22,100.00
36.110Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 0.6 TREach26,896.00
36.111Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 0.7 TREach27,735.00
36.112Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 0.8 TREach28,336.00
36.113Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 0.9 TREach29,598.00
36.114Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 1 TREach29,660.00
36.115Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 1.1 TREach32,610.00
36.116Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 1.3 TREach34,350.00
36.117Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 1.4 TREach34,650.00
36.118Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Low static ductable units (minimum 25 pascal external static pressure) - 1.6 TREach35,259.00
36.119Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 1.8 TREach38,032.00
36.120Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 2 TREach38,913.00
36.121Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 2.3 TREach39,669.00
36.122Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 2.6 TREach42,350.00
36.123Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 2.8 TREach46,782.00
36.124Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 3.4 TREach47,651.00
36.125Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - Mid static ductable units (minimum 45 pascal external static pressure) - 4 TREach48,731.00
36.126Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - High static ductable units (minimum 110 pascal external static pressure) - 5.5 TREach85,766.00
36.127Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - High static ductable units (minimum 110 pascal external static pressure) - 7.1 TREach87,281.00
36.128Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan / dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, cored remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V +_ 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temparature - High static ductable units (minimum 110 pascal external static pressure) - 8 TREach89,590.00
36.129Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre245.00
36.130Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 9.5mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre331.00
36.131Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre466.00
36.132Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre588.00
36.133Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 19 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre707.00
36.134Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 22.2 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre865.00
36.135Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 25.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre1,022.00
36.136Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 28.58 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulationMetre1,108.00
36.137Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: -31.8 mm dia (OD) (Soft drawn) with tube thickness 1.62 mm with 19mm thick insulationMetre1,170.00
36.138Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 34.9 mm dia (OD) (Soft drawn) with tube thickness 1.62 mm with 19mm thick insulationMetre1,230.00
36.139Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV / VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as required: - 38.1 mm dia (OD) (Soft drawn) with tube thickness 1.62 mm with 19mm thick insulationMetre1,265.00

Pricing energy conservation building code against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.

See how estimation works