Panel Mounting MCCBs rates

113 panel mounting mccbs items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.

Panel Mounting MCCBs rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹5,826.00 to ₹4,01,220.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. Reference only — verify against the official source before pricing a bid.

113 items — scroll the table to browse

DescriptionUnit
MAT-02953Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I63-100A 3 Pole MCCB,16 KANos8,286.00
MAT-02954Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I63-100A 4 Pole MCCB,16 KANos8,933.00
MAT-02955Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I125A 3 Pole MCCB,25 KANos9,710.00
MAT-02956Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I125A 4 Pole MCCB,25 KANos11,264.00
MAT-02957Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I160A 3 Pole MCCB,25 KANos12,300.00
MAT-02958Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I160A 4 Pole MCCB,25 KANos15,795.00
MAT-02959Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I250A 3 Pole MCCB,36/35 KANos20,068.00
MAT-02960Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I250A 4 Pole MCCB,36/35 KANos26,477.00
MAT-02961Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I400A 3 Pole MCCB,36/35 KANos26,336.00
MAT-02962Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I400A 4 Pole MCCB,36/35 KANos33,015.00
MAT-02963Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I630A 3 Pole MCCB,50 KANos39,488.00
MAT-02964Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I630A 4 Pole MCCB,50 KANos48,551.00
MAT-02965Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I800A 3 Pole MCCB,50 KANos72,503.00
MAT-02966Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category I800A 4 Pole MCCB,50 KANos77,682.00
MAT-02967Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II63-100A 3 Pole MCCB,16 KANos5,826.00
MAT-02968Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II63-100A 4 Pole MCCB,16 KANos7,575.00
MAT-02969Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II125A 3 Pole MCCB,25 KANos7,380.00
MAT-02970Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II125A 4 Pole MCCB,25 KANos9,646.00
MAT-02971Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II160A 3 Pole MCCB,25 KANos10,099.00
MAT-02973Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II250A 3 Pole MCCB,36/35 KANos19,679.00
MAT-02974Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II250A 4 Pole MCCB,36/35 KANos23,822.00
MAT-02975Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II400A 3 Pole MCCB,36/35 KANos24,729.00
MAT-02976Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II400A 4 Pole MCCB,36/35 KANos29,649.00
MAT-02977Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II630A 3 Pole MCCB,50 KANos34,957.00
MAT-02978Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II630A 4 Pole MCCB,50 KANos42,207.00
MAT-02979Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II800A 3 Pole MCCB,50 KANos60,204.00
MAT-02980Supply of ………., adjustable, confirms to IEC 60947-2 and IS 13947-Part 1 & 2, having Breaking Capacity ………. with thermal magnetic release Panel Mounted. Makes: As per list of recommended brands as category II800A 4 Pole MCCB,50 KANos67,324.00
MAT-02981Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I630A, 3 Pole, 50kA, electrically operated, fixed typeNos1,38,220.00
MAT-02982Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I630A, 3 Pole, 50kA, electrically operated, manually draw out typeNos1,58,458.00
MAT-02983Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I630A, 4 Pole, 50kA, electrically operated, fixed typeNos1,65,297.00
MAT-02984Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I630A, 4 Pole, 50kA electrically operated, manually draw out typeNos1,98,847.00
MAT-02985Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I800A, 3 Pole, 50kA electrically operated, manually draw out typeNos1,58,458.00
MAT-02986Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I800A, 4 Pole, 50kA electrically operated, manually draw out typeNos2,00,542.00
MAT-02987Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1000A, 3 Pole, 50kA electrically operated, manually draw out typeNos1,64,805.00
MAT-02988Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1000A, 4 Pole, 50kA electrically operated, manually draw out typeNos2,08,263.00
MAT-02989Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1250A, 3 Pole, 50kA electrically operated, manually draw out typeNos1,81,805.00
MAT-02990Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1250A, 4 Pole, 50kA electrically operated, manually draw out typeNos2,29,424.00
MAT-02991Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1600A, 3 Pole, 50kA electrically operated, manually draw out typeNos2,06,771.00
MAT-02992Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I1600A, 4 Pole, 50kA electrically operated, manually draw out typeNos2,54,297.00
MAT-02993Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I2000A, 3 Pole, 75kA electrically operated, manually draw out typeNos2,42,873.00
MAT-02994Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I2000A, 4 Pole, 75kA electrically operated, manually draw out typeNos2,98,322.00
MAT-02995Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I2500A, 3 Pole, 75kA electrically operated, manually draw out typeNos3,00,246.00
MAT-02996Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I2500A, 4 Pole, 75kA electrically operated, manually draw out typeNos3,61,814.00
MAT-02997Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I3200A, 3 Pole, 75kA electrically operated, manually draw out typeNos3,39,653.00
MAT-02998Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category I3200A, 4 Pole, 75kA electrically operated, manually draw out typeNos4,01,220.00
MAT-02999Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II630A, 3 Pole, 50kA, electrically operated, fixed typeNos1,24,398.00
MAT-03000Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II630A, 3 Pole, 50kA, electrically operated, manually draw out typeNos1,42,612.00
MAT-03001Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II630A, 4 Pole, 50kA, electrically operated, fixed typeNos1,48,767.00
MAT-03002Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II630A, 4 Pole, 50kA electrically operated, manually draw out typeNos1,78,963.00
MAT-03003Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II800A, 3 Pole, 50kA electrically operated, manually draw out typeNos1,42,612.00
MAT-03004Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II800A, 4 Pole, 50kA electrically operated, manually draw out typeNos1,80,488.00
MAT-03005Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II1000A, 3 Pole, 50kA electrically operated, manually draw out typeNos1,48,325.00
MAT-03006Supply of Air Circuit Breaker confirms to IS 13947-2, IEC 60947-2 and BS-EN 60947 with Micro processer based having overload, shot circuit and earth fault protection with display and 20 faults History backup with BMS compatible communication ports. Makes: As per list of recommended brands as category II1000A, 4 Pole, 50kA electrically operated, manually draw out typeNos1,87,436.00
MAT-03007Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.400Amp, 50 - 53KARm14,118.00
MAT-03008Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.630Amp, 50 - 63KARm16,781.00
MAT-03009Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.800 Amp, 50 - 76KARm18,394.00
MAT-03010Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1000 Amp, 50 - 76KARm21,137.00
MAT-03011Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1250 Amp, 50 - 76KARm22,106.00
MAT-03012Supply, installation, testing and commissioning of ........Amp, ........KA breaking capacity (100% Neutral busbar) air insulated compact Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 0.8 mm having degree of protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four strip ALUMINIUM busbar in convenient sections including necessary end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System etc., with necessary joints Fire barrier at each floor Provision of tapping at each floor/every meter, continuous earthing with 2 no aluminum strip of suitable size (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1600 Amp, 50 - 76KARm27,754.00
MAT-03014Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.400 AmpsNos16,136.00
MAT-03015Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.630 AmpsNos18,394.00
MAT-03016Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.800 AmpsNos19,201.00
MAT-03017Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.1000AmpsNos22,509.00
MAT-03018Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.1250 AmpsNos24,202.00
MAT-03019Supply and fixing of ……. Amps Horizontal / Vertical bends for Air Insulated Bus Duct. Makes: As per list of recommended brands.1600 AmpsNos27,431.00
MAT-03020Supply and fixing of …...Amps Tap off box for Air Insulated Busduct. Makes: As per list of recommended brands.125ANos19,201.00
MAT-03022Supply and fixing of …...Amps Tap off box for Air Insulated Busduct. Makes: As per list of recommended brands.400ANos32,915.00
MAT-03023Supply and fixing of …...Amps Tap off box for Air Insulated Busduct. Makes: As per list of recommended brands.630 ANos35,819.00
MAT-03024Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.630Amp, 36/40Rm17,264.00
MAT-03025Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.800Amp, 42/50KARm19,363.00
MAT-03026Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1000Amp, 50KARm21,298.00
MAT-03027Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1250 Amp,75kARm22,267.00
MAT-03028Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.1600 Amp,80 kARm27,913.00
MAT-03029Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.2000 Amp ,80kARm34,206.00
MAT-03030Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.2500 Amp ,150 kARm49,051.00
MAT-03031Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.3200 Amp,160kARm56,797.00
MAT-03032Supply, installation, testing and commissioning of .......Amp, ............KA breaking capacity (100% Neutral busbar) Aluminum sandwich busduct system, Class F, made of CRCA sheet/Hot Galvanized steel encloser of thickness not less than 1.5mm having degree of protection of IP 55/IP 65 as per IEC/EN 61439-6, Halogen free and Fire retardant in compliance with standard EN 60332-3, insulated and separated by from each other by double layer of polyester film Class F, self-extinguishing material, non- desiccant, with high dielectric strength in convenient sections including end cover units suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. system etc., with necessary joints, provision of tapping at each floor/every meter, continuous earthing with 50x6mm of 2 of aluminum strip (one on each side0 including GI clamping brackets, angle iron brackets, steel fasteners, connecting to earth system as required . Makes: As per list of recommended brands.4000 Amp,160kARm75,996.00
MAT-03033Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.630ANos17,588.00
MAT-03034Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.800ANos19,040.00
MAT-03035Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.1000ANos19,846.00
MAT-03036Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.1250 ANos21,461.00
MAT-03037Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.1600 ANos24,527.00
MAT-03038Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.2000 ANos28,559.00
MAT-03039Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.2500 ANos35,982.00
MAT-03040Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.3200 ANos43,727.00
MAT-03041Supply and fixing of ……. Amps Horizontal / Vertical bends for sandwich Bus Duct. Makes: As per list of recommended brands.4000 ANos49,051.00
MAT-03042Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.400ANos37,596.00
MAT-03043Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.630ANos39,854.00
MAT-03044Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.800ANos43,405.00
MAT-03045Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.1000ANos45,662.00
MAT-03047Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.1600 ANos52,116.00
MAT-03048Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.2000 ANos56,797.00
MAT-03049Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.2500 ANos64,540.00
MAT-03050Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.3200 ANos69,058.00
MAT-03051Supply and fixing of ……. Amps Copper Flexibles for three phases and neutral for Air Insulated / sandwich Busduct. Makes: As per list of recommended brands.4000 ANos73,738.00
MAT-03052Supply and fixing of Flange end for ………. Amps for Air insulated Bus ducts. Makes: As per list of recommended brands.400ANos14,521.00
MAT-03053Supply and fixing of Flange end for ………. Amps for Air insulated Bus ducts. Makes: As per list of recommended brands.630ANos19,846.00
MAT-03054Supply and fixing of Flange end for ………. Amps for Air insulated Bus ducts. Makes: As per list of recommended brands.800ANos24,527.00
MAT-03055Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.400ANos17,588.00
MAT-03056Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.630ANos25,172.00
MAT-03057Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.800ANos29,205.00
MAT-03058Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.1000 ANos30,819.00
MAT-03059Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.1250 ANos33,657.00
MAT-03060Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.1600 ANos35,277.00
MAT-03062Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.2500 ANos63,411.00
MAT-03063Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.3200 ANos69,382.00
MAT-03064Supply and fixing of Flange end for ………. Amps for sandwich bus ducts Makes: As per list of recommended brands.4000 ANos72,931.00
MAT-03065Supply and fixing of …...Amps Tap off box for Sandwich Busduct. Makes: As per list of recommended brands.160ANos24,202.00
MAT-03066Supply and fixing of …...Amps Tap off box for Sandwich Busduct. Makes: As per list of recommended brands.250ANos40,661.00
MAT-03067Supply and fixing of …...Amps Tap off box for Sandwich Busduct. Makes: As per list of recommended brands.400ANos51,471.00
MAT-03068Supply and fixing of …...Amps Tap off box for Sandwich Busduct. Makes: As per list of recommended brands.630ANos74,705.00
MAT-03069Supply and fixing of …...Amps Tap off box for Sandwich Busduct. Makes: As per list of recommended brands.800ANos1,12,140.00
ELEC-2.9.6Supply and Fixing of Spring Bracket with fixing kit for Air Insulated Busduct / Raising Mains. Makes: As per list of recommended brandsNos8,390.00

Other chapters in this schedule

Pricing panel mounting mccbs against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.