7 generators specification items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
Generators Specification rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹251.00 to ₹3,30,330.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. Reference only — verify against the official source before pricing a bid.
7 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| MAT-04517 | Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:25 to 40 KVA | Nos | 95,288.00 |
| MAT-04518 | Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:50 to 63.5 KVA | Nos | 1,39,755.00 |
| MAT-04519 | Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:80 to 160 KVA | Nos | 1,96,928.00 |
| MAT-04520 | Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:180 to 250 KVA | Nos | 2,66,805.00 |
| MAT-04521 | Supply Installation Testing and Commissioning of AUTO MAINS FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA sheet steel 2mmThick , Powder coated finish , Engine START & STOP commands, control RELAYS, selector switches for Ammeter & Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG Supply of required rating and breaking capacity, automatic battery charger(External charger for DG) Control & Power Contactors, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets:320 to 500 KVA | Nos | 3,30,330.00 |
| ELEC-10.1.3 | Supply and fixing of Thermal Insulation with asbestos Rope for Exhaust pipe | Metre | 251.00 |
| ELEC-10.1.4 | Supply and fixing of Thermal Insulation with Rock/Glass Wool with Aluminum cladding (Density - 96 Kg/m3 thickness -50mm) for Exhaust pipe | Metre | 1,247.00 |
Other chapters in this schedule
- Bricks & Building Blocks (21)
- Natural Flooring Stones (23)
- Wall & Floor Tiles (40)
- Paving & Interlocking Tiles (25)
- Timber & Roofing Materials (23)
- Steel Materials (26)
- Fixtures for Doors & Windows (103)
- Construction Chemicals & Admixtures (89)
- Glass Materials (21)
- Paints & Polishes (42)
- Particle Boards (110)
- Plywoods, Laminates & Veneers (31)
- Ceilings, Wall Partitions & Wall Linings (103)
- Doors, Shutters & Frames (113)
- Windows (99)
- Structural Glazing & Curtain Walling (6)
- Dismantling (13)
- Expansion Joint Fillers (11)
- Miscellaneous Items (305)
- Expansion Joints (6)
- Energy Efficient Items (33)
- S.W.G. Pipes & Fittings (62)
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 1986 (6)
- C.I. Pipes & Fittings as per IS 1729:1979 (41)
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 1974 (39)
- Taps & Faucets (6)
- G.I. Pipes & Fittings (15)
- PVC Pipes & Fittings (26)
- M.S. Conduit Pipes (51)
- PVC Conduits (36)
- Hot Dip Galvanized Metal Boxes for Switch Boards (9)
- T.W. Boards (25)
- Copper Flexible Cables (as per IS:694) (66)
- Service Mains and Flat Cable for Submersible Motors (16)
- Flush Type Switches and Accessories (27)
- Modular Switches and Accessories (49)
- Panel Mounting Switch Disconnector Fuse Units (sdfu) (10)
- On Load Changeover Switches (open Execution) (10)
- Auto Transfer Switch (14)
- Rewirable / Double Break Switches in SS Enclosure (12)
- Hrc Fuse Links (DIN/BOLTED Type) (6)
- Porcelain Rewirable Fuse Units (6)
- Panel Mounting MCCBs (113)
- MCBs (as per IS:60898-1:2002) (23)
- Isolators Confirms to I E C 60947 PART-III (22)
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-1 (22)
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3) (44)
- Automatic Street Light Control Systems (12)
- Flourscent Tubes / CFL Lamps / LED Bulbs (5)
- LED Luminaires Indoor (74)
- U.G. Cables (135)
- Cable Trays (19)
- Double Walled Corrugated HDPE Pipe (8)
- Fans (18)
- Water Heaters (conventional & Solar) (14)
- Accessories for Water Heaters (11)
- Pumpsets (96)
- Air Conditioners (15)
- HVAC SYSTEMS(VRV/VRF) (70)
- Stabilizers (10)
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners (76)
- Swaged / Octagonal Poles and Garden Posts (49)
- LT Panel and Accessories (33)
- Sub Station Equipment and Transformers (18)
- Maintenance and Repairs of Transformers (21)
- Overhead Lines& Line Materials (27)
- Lightening Protective System (16)
- Earthing (19)
- Local Area Network (59)
- Raceways and Junction Boxes (9)
- Computers, Printers and Scanners (16)
- Small System (7)
- Large EPABX System (16)
- C.C.TV & Surveillance System (16)
- Public Address Systems (15)
- AUDIO-VIDEO Systems (32)
- Legend Plates (8)
- Copper / Aluminium / G.I. Items (per Kg) (6)
- SMC Type Supports for the Busbars (36)
- Addressable - Fire Alarm System (27)
- Conventional - Fire Alarm System (14)
- Powder Based Fire Extinguishers (18)
- Fire Hydrant and Sprinkler System (58)
- Inverters and Online UPS Systems (34)
- Temporary Illumination (57)
- Lifts (new Installation) (9)
- Medical Gas Pipeline System (10)
- Building Management Systems (21)
Pricing generators specification against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.