Andhra Pradesh SOR 2026-27
Air Conditioners rates
15 air conditioners items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
Air Conditioners rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹52,809.00 to ₹1,98,043.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. Reference only — verify against the official source before pricing a bid.
15 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| MAT-03753 | Supply of ...............INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.1.5 TR, 5 star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R- 410A, COP not less than 4.5. Makes: As per list of recommended brands as category I | Nos | 67,642.00 |
| MAT-03754 | Supply of ...............INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.1.5 TR, 5 star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R- 410A, COP not less than 4.5. Makes: As per list of recommended brands as category II | Nos | 52,809.00 |
| MAT-05515 | Supply of ...............INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.1.8/1.9/2.0TR, 4/5 star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32 Makes: As per list of recommended brands as category I | Nos | 81,010.00 |
| MAT-05516 | Supply of ...............INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.1.8/1.9/2.0TR, 4/5 Star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32 Makes: As per list of recommended brands as category II | Nos | 65,966.00 |
| MAT-03757 | Supply of ...............INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser.2.2 TR, 4/5 star capable of delivering 26400 BTU/hr and above with operating on refrigerant R-410A / R- 32 Makes: As per list of recommended brands as category I | Nos | 90,012.00 |
| MAT-03759 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.1.5 TR, 4-star Single Phase capable of delivering 18000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category I | Nos | 96,962.00 |
| MAT-03760 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.2.0TR, 4-star Single Phase capable of delivering 24000 BTU / hr and above with operating on refrigerant R-32 / R-410A, . Makes: As per list of recommended brands as category I | Nos | 1,08,784.00 |
| MAT-03761 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.2.0TR 4-star Single Phase capable of delivering 24000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category II | Nos | 94,875.00 |
| MAT-03762 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.3.5 TR 4-star Three Phase capable of delivering 42000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category I | Nos | 1,83,299.00 |
| MAT-03763 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.3.5 TR 4-star Three Phase capable of delivering 42000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category II | Nos | 1,71,408.00 |
| MAT-03764 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.4.0 TR 4-star Three Phase capable of delivering 48000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category I | Nos | 1,98,043.00 |
| MAT-03765 | Supply of .......... inverter Cassette type AC unit with ceiling mounted indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc. complete with Wireless remote controller, without refrigerant piping and cable with copper condenser.4.0 TR 4-star Three Phase capable of delivering 48000 BTU / hr and above with operating on refrigerant R-32 / R-410A. Makes: As per list of recommended brands as category II | Nos | 1,63,185.00 |
| MAT-03766 | Supply of Slim line / Tower Model/Verticool type ..........split AC unit with indoor unit and floor mounted outdoor condensing unit with 3.5 mtr of copper piping, insulation kit and 4 mtr of 4 core copper flexible card with refrigerant 410A/R32, Hermetically sealed Scroll compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc complete with cordless remote control3.0/ 3.3TR Three Phase capable of delivering 39600 BTU/hr and above with operating on refrigerant R- 32/R-410. Makes: As per list of recommended brands | Nos | 1,20,871.00 |
| MAT-03767 | Supply of Slim line / Tower Model/Verticool type ..........split AC unit with indoor unit and floor mounted outdoor condensing unit with 3.5 mtr of copper piping, insulation kit and 4 mtr of 4 core copper flexible card with refrigerant 410A/R32, Hermetically sealed Scroll compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc complete with cordless remote control3.8 /4.0TR Three Phase capable of delivering 45600 BTU/hr and above with operating on refrigerant R- 32/R-410. Makes: As per list of recommended brands | Nos | 1,28,177.00 |
| MAT-03768 | Supply of Slim line / Tower Model/Verticool type ..........split AC unit with indoor unit and floor mounted outdoor condensing unit with 3.5 mtr of copper piping, insulation kit and 4 mtr of 4 core copper flexible card with refrigerant 410A/R32, Hermetically sealed Scroll compressor suitable for operation on AC supply capable of performing cooling dehumidifying air circulating and filtering with cooling and condensing units etc complete with cordless remote control4.5/ 4.6TR Three Phase capable of delivering 55200 BTU/hr and above with operating on refrigerant R- 32/R-410. Makes: As per list of recommended brands | Nos | 1,39,466.00 |
Other chapters in this schedule
- Bricks & Building Blocks (21)
- Natural Flooring Stones (23)
- Wall & Floor Tiles (40)
- Paving & Interlocking Tiles (25)
- Timber & Roofing Materials (23)
- Steel Materials (26)
- Fixtures for Doors & Windows (103)
- Construction Chemicals & Admixtures (89)
- Glass Materials (21)
- Paints & Polishes (42)
- Particle Boards (110)
- Plywoods, Laminates & Veneers (31)
- Ceilings, Wall Partitions & Wall Linings (103)
- Doors, Shutters & Frames (113)
- Windows (99)
- Structural Glazing & Curtain Walling (6)
- Dismantling (13)
- Expansion Joint Fillers (11)
- Miscellaneous Items (305)
- Expansion Joints (6)
- Energy Efficient Items (33)
- S.W.G. Pipes & Fittings (62)
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 1986 (6)
- C.I. Pipes & Fittings as per IS 1729:1979 (41)
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 1974 (39)
- Taps & Faucets (6)
- G.I. Pipes & Fittings (15)
- PVC Pipes & Fittings (26)
- M.S. Conduit Pipes (51)
- PVC Conduits (36)
- Hot Dip Galvanized Metal Boxes for Switch Boards (9)
- T.W. Boards (25)
- Copper Flexible Cables (as per IS:694) (66)
- Service Mains and Flat Cable for Submersible Motors (16)
- Flush Type Switches and Accessories (27)
- Modular Switches and Accessories (49)
- Panel Mounting Switch Disconnector Fuse Units (sdfu) (10)
- On Load Changeover Switches (open Execution) (10)
- Auto Transfer Switch (14)
- Rewirable / Double Break Switches in SS Enclosure (12)
- Hrc Fuse Links (DIN/BOLTED Type) (6)
- Porcelain Rewirable Fuse Units (6)
- Panel Mounting MCCBs (113)
- MCBs (as per IS:60898-1:2002) (23)
- Isolators Confirms to I E C 60947 PART-III (22)
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-1 (22)
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3) (44)
- Automatic Street Light Control Systems (12)
- Flourscent Tubes / CFL Lamps / LED Bulbs (5)
- LED Luminaires Indoor (74)
- U.G. Cables (135)
- Cable Trays (19)
- Double Walled Corrugated HDPE Pipe (8)
- Fans (18)
- Water Heaters (conventional & Solar) (14)
- Accessories for Water Heaters (11)
- Pumpsets (96)
- HVAC SYSTEMS(VRV/VRF) (70)
- Stabilizers (10)
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners (76)
- Swaged / Octagonal Poles and Garden Posts (49)
- LT Panel and Accessories (33)
- Sub Station Equipment and Transformers (18)
- Maintenance and Repairs of Transformers (21)
- Overhead Lines& Line Materials (27)
- Lightening Protective System (16)
- Earthing (19)
- Local Area Network (59)
- Raceways and Junction Boxes (9)
- Computers, Printers and Scanners (16)
- Small System (7)
- Large EPABX System (16)
- C.C.TV & Surveillance System (16)
- Public Address Systems (15)
- AUDIO-VIDEO Systems (32)
- Legend Plates (8)
- Copper / Aluminium / G.I. Items (per Kg) (6)
- SMC Type Supports for the Busbars (36)
- Addressable - Fire Alarm System (27)
- Conventional - Fire Alarm System (14)
- Powder Based Fire Extinguishers (18)
- Fire Hydrant and Sprinkler System (58)
- Generators Specification (7)
- Inverters and Online UPS Systems (34)
- Temporary Illumination (57)
- Lifts (new Installation) (9)
- Medical Gas Pipeline System (10)
- Building Management Systems (21)
Pricing air conditioners against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.
See how estimation works