R/ANDHRA PRADESH SOR 2026-27
Lightening Protective System rates
16 lightening protective system items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
- Items
- 16
- Lowest rate
- ₹61.00
- Highest rate
- ₹35,090.00
- Effective from
- 2026-06-01
S-01/RATE ITEMS16 ITEMS
Lightening Protective System rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹61.00 to ₹35,090.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. For reference only: verify against the official source before pricing a bid.
/
Unit
16 items. Scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| ELEC-6.6.2 | Installation and commissioning of advanced lighting protection systems which includes: 1. Laying of CC Bed 2. Installation of Lighting Rod 3. Laying of Down conductor 4. Installation of Counter 5. Installation of GI Mast with stay wire. 6. Termination of down conductor to earth bus etc complete | Nos | 35,090.00 |
| ELEC-6.6.3 | Supply of 6 Digit Electronic/Mechanical counter Makes: As per list of recommended brands | Nos | 18,150.00 |
| ELEC-6.6.4 | Supply of G.I mast of 5 Meters length, 50 mm Dia, with FRP Collar (Insulating Bush) Base Plate & Complete Fitting Accessories with Supporting Guy Wire (Stay Wires) and all fitting accessories | Set | 7,260.00 |
| ELEC-6.6.5 | Supply and Installation of IEC 62561-7 compliant Eco-friendly, Maintenance free, anti-corrosive, lead- free, super conductive, mineral based high-grade earthing compound, to enhance soil conductivity. With resistance <0.12 ohms-meter, Sulphur Free, should be tested as per IEC-62561-7 for resistance Toxic Elements, Leachable elements etc. 25 Kg Bag Makes: As per list of recommended brands | Nos | 2,662.00 |
| ELEC-6.6.6 | Supply of Bentonite Moisture Retaining Powder 30 Kg Bag | Nos | 206.00 |
| ELEC-6.6.7 | Supply of Concrete Earth Pit of Dimensions: Width: 320 mm, Length: 320 mm, Height: 192mm, Weight 30 Kgs, Load bearing Capacity: 5000 Kgs | Nos | 1,815.00 |
| ELEC-6.6.8 | Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor complete as per requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) | Rm | 109.00 |
| ELEC-6.6.9 | Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance | Each | 61.00 |
| ELEC-6.6.10 | Supply, installation, testing and commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance | Each | 157.00 |
| ELEC-6.6.11 | Supply, installation, testing and commissioning of Fang Fix Junior system - Inclusive of Al interception rod of 1Mtr length (10mm dia), Quick mounting of the interception rod in the base using plug technology | Each | 1,997.00 |
| ELEC-6.6.12 | Supply, installation, testing and commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanized iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts | Each | 160.00 |
| ELEC-6.6.13 | Supply, installation, testing and commissioning of expansion piece with connector: For equalizing temperature related length changes. Necessary on conductors of length over 20 meters. For round conductor Rd 8/ALU connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high- grade hot dip galvanized. Confirms to the requirements according to DIN VDE 0185-305 (IS-IEC 2305)(2nos/expansion piece ) | Each | 479.00 |
| ELEC-6.6.14 | Supply, installation, testing and commissioning of 8 mm Aluminum Round Conductor complete as specified in drawing & meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185- 305 (IS/IEC 62305) | Rm | 109.00 |
| ELEC-6.6.15 | Supply, installation, testing and commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or | Each | 61.00 |
| ELEC-6.6.16 | Supply, installation, testing and commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer | Each | 375.00 |
| ELEC-6.6.17 | Supply, installation, testing and commissioning of Lightning counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6 | Each | 19,965.00 |
S-02/SOURCE RECORD2026-27
- ISSUED BY
- Board of Chief Engineers, Government of Andhra Pradesh
- EFFECTIVE
- 2026-06-01Parts I, II and IV of the 2026-27 schedule — Water Resources, Roads & Bridges, and Public Health — are not reproduced here. See the official source for those.
- RETRIEVED
- 2026-07-29
S-03/CHAPTERS88 MORE
Other chapters in this schedule
- Bricks & Building Blocks21
- Natural Flooring Stones23
- Wall & Floor Tiles40
- Paving & Interlocking Tiles25
- Timber & Roofing Materials23
- Steel Materials26
- Fixtures for Doors & Windows103
- Construction Chemicals & Admixtures89
- Glass Materials21
- Paints & Polishes42
- Particle Boards110
- Plywoods, Laminates & Veneers31
SHOW ALL 88 CHAPTERS
- Ceilings, Wall Partitions & Wall Linings103
- Doors, Shutters & Frames113
- Windows99
- Structural Glazing & Curtain Walling6
- Dismantling13
- Expansion Joint Fillers11
- Miscellaneous Items305
- Expansion Joints6
- Energy Efficient Items33
- S.W.G. Pipes & Fittings62
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 19866
- C.I. Pipes & Fittings as per IS 1729:197941
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 197439
- Taps & Faucets6
- G.I. Pipes & Fittings15
- PVC Pipes & Fittings26
- M.S. Conduit Pipes51
- PVC Conduits36
- Hot Dip Galvanized Metal Boxes for Switch Boards9
- T.W. Boards25
- Copper Flexible Cables (as per IS:694)66
- Service Mains and Flat Cable for Submersible Motors16
- Flush Type Switches and Accessories27
- Modular Switches and Accessories49
- Panel Mounting Switch Disconnector Fuse Units (sdfu)10
- On Load Changeover Switches (open Execution)10
- Auto Transfer Switch14
- Rewirable / Double Break Switches in SS Enclosure12
- Hrc Fuse Links (DIN/BOLTED Type)6
- Porcelain Rewirable Fuse Units6
- Panel Mounting MCCBs113
- MCBs (as per IS:60898-1:2002)23
- Isolators Confirms to I E C 60947 PART-III22
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-122
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3)44
- Automatic Street Light Control Systems12
- Flourscent Tubes / CFL Lamps / LED Bulbs5
- LED Luminaires Indoor74
- U.G. Cables135
- Cable Trays19
- Double Walled Corrugated HDPE Pipe8
- Fans18
- Water Heaters (conventional & Solar)14
- Accessories for Water Heaters11
- Pumpsets96
- Air Conditioners15
- HVAC SYSTEMS(VRV/VRF)70
- Stabilizers10
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners76
- Swaged / Octagonal Poles and Garden Posts49
- LT Panel and Accessories33
- Sub Station Equipment and Transformers18
- Maintenance and Repairs of Transformers21
- Overhead Lines& Line Materials27
- Earthing19
- Local Area Network59
- Raceways and Junction Boxes9
- Computers, Printers and Scanners16
- Small System7
- Large EPABX System16
- C.C.TV & Surveillance System16
- Public Address Systems15
- AUDIO-VIDEO Systems32
- Legend Plates8
- Copper / Aluminium / G.I. Items (per Kg)6
- SMC Type Supports for the Busbars36
- Addressable - Fire Alarm System27
- Conventional - Fire Alarm System14
- Powder Based Fire Extinguishers18
- Fire Hydrant and Sprinkler System58
- Generators Specification7
- Inverters and Online UPS Systems34
- Temporary Illumination57
- Lifts (new Installation)9
- Medical Gas Pipeline System10
- Building Management Systems21
ARCHED / ESTIMATING
Pricing lightening protective system against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index and catching where rates have moved since the base edition takes time and is easy to get wrong. We can do it for you: send the tender and we return a priced BOQ on the applicable schedule, with rate build-ups and an engineer's sign-off.