R/ANDHRA PRADESH SOR 2026-27
C.I. Pipes & Fittings as per IS 1729:1979 rates
41 c.i. pipes & fittings as per is 1729:1979 items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
- Items
- 41
- Lowest rate
- ₹58.00
- Highest rate
- ₹1,937.00
- Effective from
- 2026-06-01
S-01/RATE ITEMS41 ITEMS
C.I. Pipes & Fittings as per IS 1729:1979 rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹58.00 to ₹1,937.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. For reference only: verify against the official source before pricing a bid.
/
Unit
41 items. Scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| BMW-C.07 | Labour charges only forfixing of C.I. Single/ Double Socket soil pipes of any dia with cement caulked joints and fixing as per site requirements including painting black with Japan paint and fixing with necessary wooden blocks fixed in the masonry walls in cement mortar and including fixing of M.S. clamps if necessary with required nails | Rm | 289.00 |
| BMW-C.08 | Supplying & fixing CI Plain bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for3" dia (76.2 mm) | Each | 298.00 |
| BMW-C.09 | Supplying & fixing CI Plain bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for4" dia (101.6 mm) | Each | 373.00 |
| BMW-C.10 | Supplying & fixing CI Plain bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for6" dia (152.4 mm) | Each | 612.00 |
| BMW-C.11 | Supplying & fixing CI Plug (Door) bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 3" dia (76.2 mm) | Each | 365.00 |
| BMW-C.12 | Supplying & fixing CI Plug (Door) bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 4" dia (101.6 mm) | Each | 450.00 |
| BMW-C.13 | Supplying & fixing CI Plug (Door) bends Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 6" dia (152.4 mm) | Each | 968.00 |
| BMW-C.14 | Labour charges only for fixing CI Plain/ Plug (Door) bends with cement caulked joints and fixing as per site requirements with standard practice | Each | 91.00 |
| BMW-C.15 | Supplying and fixing of 76.2 mm (3") CI soil single junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 463.00 |
| BMW-C.16 | Supplying and fixing of 101.6 mm (4") CI soil single junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 712.00 |
| BMW-C.17 | Supplying and fixing of 152.4 mm (6") CI soil single junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 1,664.00 |
| BMW-C.18 | Supplying and fixing of 76.2 mm (3") CI soil plain single junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 392.00 |
| BMW-C.19 | Supplying and fixing of 101.6 mm (4") CI soil plain single junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 528.00 |
| BMW-C.20 | Supplying and fixing of 152.4 mm (6") CI soil plain single junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 1,244.00 |
| BMW-C.21 | Labour charges only fixing CI soil single junctions with cement caulked joints and fixing as per site requirements with standard practice | Each | 129.00 |
| BMW-C.22 | Supplying and Fixing of 76.2 mm (3") CI soil Double junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 693.00 |
| BMW-C.23 | Supplying and Fixing of 101.6 mm (4") CI soil Double junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 838.00 |
| BMW-C.24 | Supplying and Fixing of 152.4 mm (6") CI soil Double junction with plug : conforming to IS:17291979 with cement caulked joints and fixing | Each | 1,937.00 |
| BMW-C.25 | Supplying and Fixing of 76.2 mm (3") CI soil plain Double junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 601.00 |
| BMW-C.26 | Supplying and Fixing of 101.6 mm (4") CI soil plain Double junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 785.00 |
| BMW-C.27 | Supplying and Fixing of 152.4 mm (6") CI soil plain Double junction : conforming to IS:17291979 with cement caulked joints and fixing | Each | 1,816.00 |
| BMW-C.28 | Labour charges only fixing CI soil Double junctions with cement caulked joints and fixing as per site requirements with standard practice | Each | 127.00 |
| BMW-C.29 | Supplying and Fixing of 75mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 76.20 mm (3") C.I. Pipe | Each | 294.00 |
| BMW-C.30 | Supplying and Fixing of 75mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 101.6 mm (4") C.I. Pipe | Each | 409.00 |
| BMW-C.31 | Supplying and Fixing of 75mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 152.4 mm (6") C.I. Pipe | Each | 880.00 |
| BMW-C.32 | Supplying and Fixing of 115 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixing for 76.20 mm (3") C.I. Pipe | Each | 349.00 |
| BMW-C.33 | Supplying and Fixing of 115 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixing for 101.6 mm (4") C.I. Pipe | Each | 461.00 |
| BMW-C.34 | Supplying and Fixing of 115 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixing for 152.4 mm (6") C.I. Pipe | Each | 902.00 |
| BMW-C.35 | Supplying and Fixing of 150 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 76.20 mm (3") C.I. Pipe | Each | 403.00 |
| BMW-C.36 | Supplying and Fixing of 150 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 101.6 mm (4") C.I. Pipe | Each | 519.00 |
| BMW-C.37 | Supplying and Fixing of 150 mm C.I. Offsets Ist quality conforming to IS:17291979 with cement caulked joints and fixingfor 152.4 mm (6") C.I. Pipe | Each | 1,047.00 |
| BMW-C.38 | Labour charges only fixing CI soil Offsets with cement caulked joints and fixing as per site requirements with standard practice | Each | 58.00 |
| BMW-C.39 | Supplying & fixing CI floor traps 1st quality ISI marked conforming to IS:17291979 with C.P. Grating fixing with white cement as per site requirements with standard practicefor nominal dia 75 mm (3") and grating size 165 mm dia of weight not less than 5.5 Kgs | Each | 528.00 |
| BMW-C.40 | Supplying & fixing CI floor traps 1st quality ISI marked with C.P. Grating fixing with white cement as per site requirements with standard practicefornominal dia 100 mm (4") and grating size 100 mm dia of weight not less than 6 Kgs | Each | 645.00 |
| BMW-C.41 | Supplying & fixing CI floor traps 1st quality ISI marked conforming to IS:17291979 with C.P. Grating fixing with white cement as per site requirements with standard practicefor nominal dia 75 mm (3") and grating size 100 mm dia of weight not less than 4.0 Kgs | Each | 328.00 |
| BMW-C.42 | Labour charges only for fixing CI Nahany/ Floor traps with C.P. Grating fixing with white cement as per site requirements with standard practice | Each | 65.00 |
| BMW-C.43 | Boxing of Nahany traps in RCC floors | Each | 183.00 |
| BMW-C.44 | Boxing of W.C Trap in R.C.C floors | Each | 365.00 |
| BMW-C.45 | Supplying & fixing CI Collars (double socket) Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 76.20 mm (3") C.I. Pipe | Each | 174.00 |
| BMW-C.46 | Supplying & fixing CI Collars (double socket) Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 101.6 mm (4") C.I. Pipe | Each | 218.00 |
| BMW-C.47 | Supplying & fixing CI Collars (double socket) Ist quality ISI marked conforming to IS:17291979 with cement caulked joints and fixing as per site requirements with standard practice for 152.4 mm (6") C.I. Pipe | Each | 626.00 |
S-02/SOURCE RECORD2026-27
- ISSUED BY
- Board of Chief Engineers, Government of Andhra Pradesh
- EFFECTIVE
- 2026-06-01Parts I, II and IV of the 2026-27 schedule — Water Resources, Roads & Bridges, and Public Health — are not reproduced here. See the official source for those.
- RETRIEVED
- 2026-07-29
S-03/CHAPTERS88 MORE
Other chapters in this schedule
- Bricks & Building Blocks21
- Natural Flooring Stones23
- Wall & Floor Tiles40
- Paving & Interlocking Tiles25
- Timber & Roofing Materials23
- Steel Materials26
- Fixtures for Doors & Windows103
- Construction Chemicals & Admixtures89
- Glass Materials21
- Paints & Polishes42
- Particle Boards110
- Plywoods, Laminates & Veneers31
SHOW ALL 88 CHAPTERS
- Ceilings, Wall Partitions & Wall Linings103
- Doors, Shutters & Frames113
- Windows99
- Structural Glazing & Curtain Walling6
- Dismantling13
- Expansion Joint Fillers11
- Miscellaneous Items305
- Expansion Joints6
- Energy Efficient Items33
- S.W.G. Pipes & Fittings62
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 19866
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 197439
- Taps & Faucets6
- G.I. Pipes & Fittings15
- PVC Pipes & Fittings26
- M.S. Conduit Pipes51
- PVC Conduits36
- Hot Dip Galvanized Metal Boxes for Switch Boards9
- T.W. Boards25
- Copper Flexible Cables (as per IS:694)66
- Service Mains and Flat Cable for Submersible Motors16
- Flush Type Switches and Accessories27
- Modular Switches and Accessories49
- Panel Mounting Switch Disconnector Fuse Units (sdfu)10
- On Load Changeover Switches (open Execution)10
- Auto Transfer Switch14
- Rewirable / Double Break Switches in SS Enclosure12
- Hrc Fuse Links (DIN/BOLTED Type)6
- Porcelain Rewirable Fuse Units6
- Panel Mounting MCCBs113
- MCBs (as per IS:60898-1:2002)23
- Isolators Confirms to I E C 60947 PART-III22
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-122
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3)44
- Automatic Street Light Control Systems12
- Flourscent Tubes / CFL Lamps / LED Bulbs5
- LED Luminaires Indoor74
- U.G. Cables135
- Cable Trays19
- Double Walled Corrugated HDPE Pipe8
- Fans18
- Water Heaters (conventional & Solar)14
- Accessories for Water Heaters11
- Pumpsets96
- Air Conditioners15
- HVAC SYSTEMS(VRV/VRF)70
- Stabilizers10
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners76
- Swaged / Octagonal Poles and Garden Posts49
- LT Panel and Accessories33
- Sub Station Equipment and Transformers18
- Maintenance and Repairs of Transformers21
- Overhead Lines& Line Materials27
- Lightening Protective System16
- Earthing19
- Local Area Network59
- Raceways and Junction Boxes9
- Computers, Printers and Scanners16
- Small System7
- Large EPABX System16
- C.C.TV & Surveillance System16
- Public Address Systems15
- AUDIO-VIDEO Systems32
- Legend Plates8
- Copper / Aluminium / G.I. Items (per Kg)6
- SMC Type Supports for the Busbars36
- Addressable - Fire Alarm System27
- Conventional - Fire Alarm System14
- Powder Based Fire Extinguishers18
- Fire Hydrant and Sprinkler System58
- Generators Specification7
- Inverters and Online UPS Systems34
- Temporary Illumination57
- Lifts (new Installation)9
- Medical Gas Pipeline System10
- Building Management Systems21
ARCHED / ESTIMATING
Pricing c.i. pipes & fittings as per is 1729:1979 against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index and catching where rates have moved since the base edition takes time and is easy to get wrong. We can do it for you: send the tender and we return a priced BOQ on the applicable schedule, with rate build-ups and an engineer's sign-off.