Andhra Pradesh SOR 2026-27
HVAC SYSTEMS(VRV/VRF) rates
70 hvac systems(vrv/vrf) items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
HVAC SYSTEMS(VRV/VRF) rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹188.00 to ₹5,20,674.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. Reference only — verify against the official source before pricing a bid.
70 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| MAT-03769 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.6 HP | Nos | 2,20,110.00 |
| MAT-03770 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.8 HP | Nos | 2,39,844.00 |
| MAT-03771 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.10 HP | Nos | 2,97,528.00 |
| MAT-03772 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.12 HP | Nos | 3,33,960.00 |
| MAT-03773 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.14 HP | Nos | 3,77,982.00 |
| MAT-03774 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.16 HP | Nos | 4,31,112.00 |
| MAT-03775 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.18 HP | Nos | 4,73,616.00 |
| MAT-03776 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category I.20 HP | Nos | 5,20,674.00 |
| MAT-05517 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.6 HP | Nos | 2,02,653.00 |
| MAT-05518 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.8 HP | Nos | 2,20,110.00 |
| MAT-05519 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.10 HP | Nos | 2,73,695.00 |
| MAT-05520 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.12 HP | Nos | 3,07,243.00 |
| MAT-05521 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.14 HP | Nos | 3,47,622.00 |
| MAT-05522 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.16 HP | Nos | 3,96,198.00 |
| MAT-05523 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.18 HP | Nos | 4,35,666.00 |
| MAT-05524 | Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R-410A), refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: As per list of recommended brands as category II.20 HP | Nos | 4,78,170.00 |
| MAT-03780 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.1.0 TR | Nos | 38,267.00 |
| MAT-03781 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.1.6 TR | Nos | 41,745.00 |
| MAT-05526 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.1.6 TR | Nos | 39,658.00 |
| MAT-03783 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.1.0/1.3 TR | Nos | 50,929.00 |
| MAT-03784 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.1.5/1.6 TR | Nos | 57,052.00 |
| MAT-03786 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.2.6 TR | Nos | 64,009.00 |
| MAT-03788 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.4.0 TR | Nos | 66,792.00 |
| MAT-03789 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.4.5 TR | Nos | 69,993.00 |
| MAT-05529 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.1.5/1.6 TR | Nos | 52,460.00 |
| MAT-05531 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.2.6 TR | Nos | 58,861.00 |
| MAT-03791 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.4.0 TR | Nos | 66,792.00 |
| MAT-03793 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.5.5 TR | Nos | 1,06,513.00 |
| MAT-03794 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.6.3 TR | Nos | 1,12,206.00 |
| MAT-03795 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category I.8.0 TR | Nos | 1,18,278.00 |
| MAT-05538 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.5.5 TR | Nos | 97,405.00 |
| MAT-05539 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.6.3 TR | Nos | 1,02,465.00 |
| MAT-05540 | Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: As per list of recommended brands as category II.8.0 TR | Nos | 1,08,790.00 |
| MAT-03800 | Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete6 to 8 HP | Nos | 8,694.00 |
| MAT-03801 | Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete10 to 12 HP | Nos | 12,420.00 |
| MAT-03802 | Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete14 to 20 HP | Nos | 14,904.00 |
| MAT-03805 | Lifting Shifting, Positioning, Installation Testing and commissioning of the following indoor units with including all required accessories etc complete.,2.6 TR to 4.5 TR | Nos | 3,105.00 |
| MAT-03806 | Lifting Shifting, Positioning, Installation Testing and commissioning of the following indoor units with including all required accessories etc complete.,3.2 TR to 4.5 TR | Nos | 3,726.00 |
| MAT-03807 | Lifting Shifting, Positioning, Installation Testing and commissioning of the following indoor units with including all required accessories etc complete.,5.5 TR to 8.0 TR | Nos | 5,589.00 |
| MAT-03808 | Installation, testing & commissioning of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls duly wired, thermostatic control corded/cordless remote controller supports for indoor units etc.4 TR to 8 TR | Nos | 5,693.00 |
| MAT-03809 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.34.9 mm dia | Rmt | 2,424.00 |
| MAT-03810 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.28.6 mm dia | Rmt | 2,214.00 |
| MAT-03811 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.22.2 mm dia | Rmt | 2,002.00 |
| MAT-03812 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.19.1 mm dia | Rmt | 1,793.00 |
| MAT-03813 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.15.9 mm dia | Rmt | 1,582.00 |
| MAT-03814 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.12.7 mm dia | Rmt | 1,370.00 |
| MAT-03815 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.9.5 mm dia | Rmt | 1,012.00 |
| MAT-03816 | Supply, installation and testing of Refrigerant Piping consisting of copper tubes of wall thickness 20G/22G with class "O" nitrile rubber Insulation with finish as required. The piping to be mounted & supported properly with suitable size of clamp, M.S. hanger, tray etc., as required at site Makes: As per list of recommended brands.6.4 mm dia | Rmt | 886.00 |
| MAT-03817 | Supply, installation, and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings (including enlarger, bends, T- Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap.25 mm dia | Rmt | 188.00 |
| MAT-03818 | Supply, installation, and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings (including enlarger, bends, T- Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap.32 mm dia | Rmt | 224.00 |
| MAT-03819 | Supply, installation, and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings (including enlarger, bends, T- Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap.40mm dia | Rmt | 274.00 |
| MAT-03820 | Supply, installation, and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings (including enlarger, bends, T- Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap.50 mm dia | Rmt | 324.00 |
| MAT-03824 | Supply, installation, testing& commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes: As per list of recommended brands.24 G | Sqm | 1,201.00 |
| MAT-03825 | Supply, installation, testing& commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes: As per list of recommended brands.22 G | Sqm | 1,346.00 |
| MAT-03826 | Supply, installation, testing& commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes: As per list of recommended brands.20 G | Sqm | 1,601.00 |
| MAT-03827 | Supply, installation, testing& commissioning of GSS Ducting with required angle flanges & installation materials such as heavy duty supports by anchor fasteners etc as required asper IS 655 /SMACNA Standards. Makes: As per list of recommended brands.18 G | Sqm | 1,746.00 |
| MAT-03829 | Supply & Fixing of Duct Acoustic Insulation applied inside of the duct work with All. backed Open cell nitrile duly fixed with adhesive and tapes Makes: As per list of recommended brands.10/15 mm Thick | Sqm | 1,139.00 |
| ELEC-5.6.3 | Supply and Installation of Ref Nets for Double ODU connections | Nos | 6,679.00 |
| ELEC-5.6.4 | Supply and Installation of Ref Nets for Triple ODU connections | Nos | 12,802.00 |
| ELEC-5.6.5 | Supply and Installation of Multi Connection Joint / Ref Nets for IDUs | Nos | 5,844.00 |
| ELEC-5.6.22 | Supply and transportation of R 410A Gas for the system | KG | 1,571.00 |
| ELEC-5.6.24 | Supply, installation, testing & commissioning of stand-alone, intelligent Touch controller with Display for controlling the indoor & outdoor units from a Remote place for all the circuits | Nos | 93,610.00 |
| ELEC-5.6.28 | Supply, Installation, Testing and commissioning of extruded Aluminum powder coated grills/ diffusers for supply with removable core type with collar damper | Sqm | 10,753.00 |
| ELEC-5.6.29 | Supply, Installation, Testing and commissioning of extruded Aluminum powder coated grills/ diffusers for return with removable core type without collar damper | Sqm | 7,843.00 |
| ELEC-5.6.30 | Supply, Erection and Testing of GI Opposed blade Volume control dampers made out of 18G frame and 20G blades | Sqm | 6,831.00 |
| ELEC-5.6.31 | Supply, Erection of Fresh air louver with extruded aluminum grill with SS wire mesh and GI volume control damper with 20 micron filters | Sqm | 5,440.00 |
| ELEC-5.6.32 | Supply and Installation of Underdeck Insulation with 50 mm thick EPS, 48 Kg/Cum density, factory laminated faced aluminum foil covered with GI cross wiring | Sqm | 823.00 |
| ELEC-5.6.33 | Supply and Installation of GI Fusible link Fire dampers 500 mm long with sleeve as per UL 555 Standard, Minimum width of damper shall be 225 mm | Sqm | 8,223.00 |
| ELEC-5.6.34 | Supply and Installation of GI backdraft dampers as per UL 555 Standard, | Sqm | 6,831.00 |
| ELEC-5.6.35 | Supply, installation and testing of Canvas connection for the Treated Fresh Air units to the duct | Each | 2,783.00 |
Other chapters in this schedule
- Bricks & Building Blocks (21)
- Natural Flooring Stones (23)
- Wall & Floor Tiles (40)
- Paving & Interlocking Tiles (25)
- Timber & Roofing Materials (23)
- Steel Materials (26)
- Fixtures for Doors & Windows (103)
- Construction Chemicals & Admixtures (89)
- Glass Materials (21)
- Paints & Polishes (42)
- Particle Boards (110)
- Plywoods, Laminates & Veneers (31)
- Ceilings, Wall Partitions & Wall Linings (103)
- Doors, Shutters & Frames (113)
- Windows (99)
- Structural Glazing & Curtain Walling (6)
- Dismantling (13)
- Expansion Joint Fillers (11)
- Miscellaneous Items (305)
- Expansion Joints (6)
- Energy Efficient Items (33)
- S.W.G. Pipes & Fittings (62)
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 1986 (6)
- C.I. Pipes & Fittings as per IS 1729:1979 (41)
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 1974 (39)
- Taps & Faucets (6)
- G.I. Pipes & Fittings (15)
- PVC Pipes & Fittings (26)
- M.S. Conduit Pipes (51)
- PVC Conduits (36)
- Hot Dip Galvanized Metal Boxes for Switch Boards (9)
- T.W. Boards (25)
- Copper Flexible Cables (as per IS:694) (66)
- Service Mains and Flat Cable for Submersible Motors (16)
- Flush Type Switches and Accessories (27)
- Modular Switches and Accessories (49)
- Panel Mounting Switch Disconnector Fuse Units (sdfu) (10)
- On Load Changeover Switches (open Execution) (10)
- Auto Transfer Switch (14)
- Rewirable / Double Break Switches in SS Enclosure (12)
- Hrc Fuse Links (DIN/BOLTED Type) (6)
- Porcelain Rewirable Fuse Units (6)
- Panel Mounting MCCBs (113)
- MCBs (as per IS:60898-1:2002) (23)
- Isolators Confirms to I E C 60947 PART-III (22)
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-1 (22)
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3) (44)
- Automatic Street Light Control Systems (12)
- Flourscent Tubes / CFL Lamps / LED Bulbs (5)
- LED Luminaires Indoor (74)
- U.G. Cables (135)
- Cable Trays (19)
- Double Walled Corrugated HDPE Pipe (8)
- Fans (18)
- Water Heaters (conventional & Solar) (14)
- Accessories for Water Heaters (11)
- Pumpsets (96)
- Air Conditioners (15)
- Stabilizers (10)
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners (76)
- Swaged / Octagonal Poles and Garden Posts (49)
- LT Panel and Accessories (33)
- Sub Station Equipment and Transformers (18)
- Maintenance and Repairs of Transformers (21)
- Overhead Lines& Line Materials (27)
- Lightening Protective System (16)
- Earthing (19)
- Local Area Network (59)
- Raceways and Junction Boxes (9)
- Computers, Printers and Scanners (16)
- Small System (7)
- Large EPABX System (16)
- C.C.TV & Surveillance System (16)
- Public Address Systems (15)
- AUDIO-VIDEO Systems (32)
- Legend Plates (8)
- Copper / Aluminium / G.I. Items (per Kg) (6)
- SMC Type Supports for the Busbars (36)
- Addressable - Fire Alarm System (27)
- Conventional - Fire Alarm System (14)
- Powder Based Fire Extinguishers (18)
- Fire Hydrant and Sprinkler System (58)
- Generators Specification (7)
- Inverters and Online UPS Systems (34)
- Temporary Illumination (57)
- Lifts (new Installation) (9)
- Medical Gas Pipeline System (10)
- Building Management Systems (21)
Pricing hvac systems(vrv/vrf) against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.