Andhra Pradesh SOR 2026-27
LT Panel and Accessories rates
33 lt panel and accessories items from the Board of Chief Engineers, Government of Andhra Pradesh, effective 2026-06-01.
LT Panel and Accessories rates in the Andhra Pradesh Common Schedule of Rates — Part-III (Buildings, Water Supply & Electrical) 2026-27 run from ₹113.00 to ₹13,673.00. Transcribed from Government of Andhra Pradesh — Common Schedule of Rates 2026-27, Part-III (Buildings), Board of Chief Engineers. Reference only — verify against the official source before pricing a bid.
33 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| MAT-03977 | Supply and fixing of……………. bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleevesElectrolytic grade aluminum bus bar | KG | 563.00 |
| MAT-03978 | Supply and fixing of……………. bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleevesElectrolytic grade copper bus bar | KG | 1,188.00 |
| MAT-03979 | Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Makes: As per list of recommended brands.Analog type (96 mm x 96 mm) | Nos | 935.00 |
| MAT-03980 | Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Makes: As per list of recommended brands.Digital type | Nos | 2,090.00 |
| MAT-03991 | Supply and fixing of single phase Electronic energy Meter,…...AC,50 HZ as per IS13010 up to 40A range with 200% over load capacity complete with connections etc., complete on the existing board.Single Phase | Nos | 1,100.00 |
| MAT-03992 | Supply and fixing of single phase Electronic energy Meter,…...AC,50 HZ as per IS13010 up to 40A range with 200% over load capacity complete with connections etc., complete on the existing board.Three Phase | Nos | 3,080.00 |
| MAT-03993 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as requiredRed/yellow/Green colour | Nos | 132.00 |
| MAT-03994 | Supply and Fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as requiredBlue colour | Nos | 220.00 |
| MAT-04013 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.Up to 12 Amp | Nos | 950.00 |
| MAT-04014 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.13 to 32 Amp | Nos | 1,573.00 |
| MAT-04015 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.35 to 40 Amp | Nos | 1,899.00 |
| MAT-04016 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.41 to 50 Amp | Nos | 4,154.00 |
| MAT-04017 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.Up to 25 Amp | Nos | 1,187.00 |
| MAT-04018 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.26 to 32 Amp | Nos | 1,424.00 |
| MAT-04019 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.33 to 45 Amp | Nos | 2,374.00 |
| MAT-04020 | Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:60947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. Makes: As per list of recommended brands.46 to 60 Amp | Nos | 4,985.00 |
| MAT-04021 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.Up to 6 KVAR | Nos | 2,279.00 |
| MAT-04022 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.7 to 10 KVAR | Nos | 2,563.00 |
| MAT-04023 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.11 to 20 KVAR | Nos | 3,846.00 |
| MAT-04024 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.21 to 25 KVAR | Nos | 5,128.00 |
| MAT-04025 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.30 KVAR | Nos | 7,406.00 |
| MAT-04026 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.40 KVAR | Nos | 11,821.00 |
| MAT-04027 | Supply and fixing of 440 Volt 3 pole capacitor (AC 6 B) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:60947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. Makes: As per list of recommended brands.50 KVAR | Nos | 13,673.00 |
| MAT-04028 | Supply and fixing of thermal overload relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Makes: As per list of recommended brands.Up to 14 A | Nos | 1,424.00 |
| MAT-04029 | Supply and fixing of thermal overload relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Makes: As per list of recommended brands.15 to 20 A | Nos | 1,899.00 |
| MAT-04030 | Supply and fixing of thermal overload relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Makes: As per list of recommended brands.21 to 30 A | Nos | 2,730.00 |
| MAT-04031 | Supply and fixing of thermal overload relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Makes: As per list of recommended brands.31 to 40 A | Nos | 3,086.00 |
| MAT-04032 | Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Makes: As per list of recommended brands.Non-luminous type | Nos | 113.00 |
| MAT-04033 | Supply and fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Makes: As per list of recommended brands.Luminous type | Nos | 154.00 |
| ELEC-6.2.1 | Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) | Sqm | 6,145.00 |
| ELEC-6.2.6 | Supply and fixing of selector switch for voltmeter (4 position) including making connection etc. as required Makes: As per list of recommended brands | Nos | 374.00 |
| ELEC-6.2.7 | Supply and fixing of CT linked selector switch of 10 A for Ampere meter (4 position) including making connection etc. as required. Makes: As per list of recommended brands | Nos | 413.00 |
| ELEC-6.2.11 | Supply and fixing of energy analyzer (multi-function energy meter) with LCD/LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect | Nos | 11,550.00 |
Other chapters in this schedule
- Bricks & Building Blocks (21)
- Natural Flooring Stones (23)
- Wall & Floor Tiles (40)
- Paving & Interlocking Tiles (25)
- Timber & Roofing Materials (23)
- Steel Materials (26)
- Fixtures for Doors & Windows (103)
- Construction Chemicals & Admixtures (89)
- Glass Materials (21)
- Paints & Polishes (42)
- Particle Boards (110)
- Plywoods, Laminates & Veneers (31)
- Ceilings, Wall Partitions & Wall Linings (103)
- Doors, Shutters & Frames (113)
- Windows (99)
- Structural Glazing & Curtain Walling (6)
- Dismantling (13)
- Expansion Joint Fillers (11)
- Miscellaneous Items (305)
- Expansion Joints (6)
- Energy Efficient Items (33)
- S.W.G. Pipes & Fittings (62)
- Man Holes & Inspection Chambers as per IS 4111 : Part 1 : 1986 (6)
- C.I. Pipes & Fittings as per IS 1729:1979 (41)
- Vitreous Chinaware Sanitary Appliances as per IS:2556 – 1974 (39)
- Taps & Faucets (6)
- G.I. Pipes & Fittings (15)
- PVC Pipes & Fittings (26)
- M.S. Conduit Pipes (51)
- PVC Conduits (36)
- Hot Dip Galvanized Metal Boxes for Switch Boards (9)
- T.W. Boards (25)
- Copper Flexible Cables (as per IS:694) (66)
- Service Mains and Flat Cable for Submersible Motors (16)
- Flush Type Switches and Accessories (27)
- Modular Switches and Accessories (49)
- Panel Mounting Switch Disconnector Fuse Units (sdfu) (10)
- On Load Changeover Switches (open Execution) (10)
- Auto Transfer Switch (14)
- Rewirable / Double Break Switches in SS Enclosure (12)
- Hrc Fuse Links (DIN/BOLTED Type) (6)
- Porcelain Rewirable Fuse Units (6)
- Panel Mounting MCCBs (113)
- MCBs (as per IS:60898-1:2002) (23)
- Isolators Confirms to I E C 60947 PART-III (22)
- RCCBs (ELCB/RCD) Confirms to IEC:61008 and IS:12640-1 (22)
- MCB Distribution Boards (as per IS 8623; IS 13032; Iec 61439-3) (44)
- Automatic Street Light Control Systems (12)
- Flourscent Tubes / CFL Lamps / LED Bulbs (5)
- LED Luminaires Indoor (74)
- U.G. Cables (135)
- Cable Trays (19)
- Double Walled Corrugated HDPE Pipe (8)
- Fans (18)
- Water Heaters (conventional & Solar) (14)
- Accessories for Water Heaters (11)
- Pumpsets (96)
- Air Conditioners (15)
- HVAC SYSTEMS(VRV/VRF) (70)
- Stabilizers (10)
- Repairing of Fans, Coolers, Pumps, Motors, Fridges and Airconditioners (76)
- Swaged / Octagonal Poles and Garden Posts (49)
- Sub Station Equipment and Transformers (18)
- Maintenance and Repairs of Transformers (21)
- Overhead Lines& Line Materials (27)
- Lightening Protective System (16)
- Earthing (19)
- Local Area Network (59)
- Raceways and Junction Boxes (9)
- Computers, Printers and Scanners (16)
- Small System (7)
- Large EPABX System (16)
- C.C.TV & Surveillance System (16)
- Public Address Systems (15)
- AUDIO-VIDEO Systems (32)
- Legend Plates (8)
- Copper / Aluminium / G.I. Items (per Kg) (6)
- SMC Type Supports for the Busbars (36)
- Addressable - Fire Alarm System (27)
- Conventional - Fire Alarm System (14)
- Powder Based Fire Extinguishers (18)
- Fire Hydrant and Sprinkler System (58)
- Generators Specification (7)
- Inverters and Online UPS Systems (34)
- Temporary Illumination (57)
- Lifts (new Installation) (9)
- Medical Gas Pipeline System (10)
- Building Management Systems (21)
Pricing lt panel and accessories against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.