Skip to main content

Maharashtra SOR 2022-23

Water Proofing rates

39 water proofing items from the Maharashtra Public Works Department (PWD), effective 2022-07-25.

Water Proofing rates in the Maharashtra State Schedule of Rates 2022-23 run from ₹26.00 to ₹6,195.00. Transcribed from Maharashtra PWD — State Schedule of Rates 2022-23, effective 25 July 2022. Reference only — verify against the official source before pricing a bid.

39 items — scroll the table to browse

DescriptionUnit
31.01Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete.Sqm432.00
31.02Providing and applying Bitumen VG30/VG40 layer at 2 Kilogram. per One Square Meterr over the terrace, structural slab including cleaning the surface for waterproofing as directed completeSqm246.00
31.03Providing leak proof treatment by Injection grouting method to old floor without removing tiles of W.C., bath, with cement sand proportion of 1:1.5 and waterproofing compound at 2 Kilogram/bag of cement mixed in 35 liters of water including drilling holes in required position grouting with above mixed solution and ceiling etc. complete.Litre40.00
31.04Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.Sqm1,155.00
31.05Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.Sqm430.00
31.06Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)Sqm387.00
31.07Providing waterproof plaster in W.C. and bath 20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete.Sqm530.00
31.08Removing the tar or coba and disposing of the material as directed etc. complete.Sqm26.00
31.09Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre /Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.Sqm615.00
31.10Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP- 42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/ One Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/ One Square Metre and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/ One Square Metre to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.Sqm1,098.00
31.11Providing and applying a base coat comprising of 1KilogramPolydee-MC and 1Kilogramfresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs. covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete.Sqm1,267.00
31.12Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )Sqm1,286.00
31.13Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)Sqm1,338.00
31.14Providing and laying perforated PVC 160 mm dia pipe in proper line,leveland slope including necessary material fitting etc. complete.Rmt1,284.00
31.15Providing and applying required coats of a water based UV resistant Evercrete Top Seal sealant to protect natural stone, bricks, concrete and wooden structures from water intrusion and staining due to water penetration and algue formation etc completeSqm546.00
31.16Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessarySqm845.00
31.17Providing water proofing treatment as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 One Square Metre., hot bitumen layer at the rate of 14.50Kilogramper 10 One Square Metre. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50Kilogramper 10 Square Metre. and finally spreading over it grit at the rate of 14.50Kilogramper 10 Square Metre. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.Sqm617.00
31.26Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.Cum6,195.00
50.10Clean the surface to remove dirt, loose particles. Examine the surface closely for any cracks. Clean the cracks. Provide and fill a pure acrylic, polymer modified ready to use paste Polyfill AR of approved make & approved by Engineer in charge having a cream coloured viscous emulsion ready to use acrylic polymeric non-shrink crackfiller putty with auto suction properties and requiring no bonding agent, no curing and no requirement for opening the existing cracks finishing with subsequent filling as required. Provide and apply three coats of 100% acrylic waterproof heat insulating breathable decorative external coating Sunext 8 of approved make & approved by Engineer in charge, in the desired shade. Stir well and apply by brush for three coats. Applying three coats at an interval of 4-6 hours between each coat. High Performance 100% Acrylic, Waterproof, Anti-fungal, Anti-carbonation, Heat Insulating External Paint should have following minimum properties: 1. Specific Gravity: 1.3 ± 0.1 at 25°C 2. pH: 7.0 to 10.00 3. Viscosity: 18 to 30 sec. at 25°C by Ford Cup One Number B-4 (Dilute 2 parts of product with 1 part of water) 4. CO2 diffusion resistance co- efficient (DIN EN 1062-6 (2002-10): 7.59 x105 5. CO2 diffusion equivalent air layer thickness (DIN EN 1062-6 (2002-10): 127m @ 190 microns DFT 6. Adhesion (ASTM D 4541): 2.3 N/mm2 (Concrete / Substrate Failure) 7. Solar Reflectance Index (ASTM E 1980 11,EN 673:2011, EN 410:2011): 107 It shall be applied as per manufacturers specification.Sqm251.00
51.113Providing and laying Hyperplas Aluminium or equivalent polymeric multiple monolithic five layer water proofing flexible, pliable and high tensile strength membrane (3 Kilogram/ One Square Metre) which is comprise of top with "V" shape embossed 40 micron Aluminium foil to bear thermal expansion and avoiding delamination & consist of centre core of 90 micron thick High Molecular High density Polyethylene film (HMHDPE) which is protected on both the side with polymeric mix. Applying the membrane by thermofusing to roof & parapet after applying thin film of hot blown bitumen 85/25 or 90/15 grade @ 1.2 Kilogram/ One Square Metre maximum as per surface condition or Hyperplas primer @ 250 gms/ One Square Metre as per site condition on the surface to be treated with 10 cm overlapping including finishing etc. complete and covering guarantee of 7 years on stamp paper of Rs. 100/- and as directed by Engineer-in- charge. (Prior permission of S.E.in writing is necessary before inclusion of this item in estimate).Sqm853.00
51.114Providing and laying Hyperplas standard or equivalent polymeric multiple monolithic five layer water proofing flexible, pliable and high tensile strength membrane (3 Kilogram/ One Square Metre) & consist of centre core of 90 micron thick High Molecular High density Polyethylene film (HMHDPE) which is protected on both the side with polymeric mix. Applying the membrane by thermofusing to roof & parapet after applying thin film of hot blown bitumen 85/25 or 90/15 grade @ 1.2 Kilogram/ One Square Metre maximum as per surface condition or Hyperplas primer @ 250 gms/ One Square Metre as per site condition on the surface to be treated with 10 cm overlapping including finishing etc. complete and covering guarantee of 7 years on stamp paper of Rs. 100/- and as directed by Engineer-in-charge. (Prior permission of S.E.in writing is necessary before inclusion of this item in estimate).Sqm678.00
51.115Providing and laying mechanical protective layer over water proofing membrane with cement screed plaster 1:5 after laying chicken mesh over membrane including curing etc. complete 20 mm thick with cost of chicken mesh etc. complete and covering 7 years guarantee on court stamp paper of Rs.100/- including necessary testing specified by Engineer (Prior permission of S.E. is necessary before inclusion of this item in estimate) (Note :- This item shall be executed over item One Number 5 of BD-J Water Proofing)Sqm390.00
52.12Waterproofing Treatment to new terrace by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: (1) Elongation % (ASTM D412-2016): @ 100% (2) Tensile Strength N/mm2 (ASTM D412- 2016): 3.3 (3) Specific Gravity: 1.02 ± 0.02 (4) Total Solids (ASTM D1644-2012): 43.98 (5) Hardness Shore A (ASTM D2240-2015): 82Sqm1,532.00
52.13Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene- Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation % (ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2 (ASTM D412- 2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82Sqm1,532.00
52.14Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water PermeabilitySqm3,026.00
52.15Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm IPS. The procedure includes filling of cracks on the RCC slab with chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of CPTP admixed appropriately in dimethyl benzene Primer as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of continuous chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of CPTP is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in CC M – 20 by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Specific Gravity: 1.30 ± 0.1 2) Elongation %: >600 3) Tack Free Time: 24-48 hrs 4) Tensile Strength N/mm2: 2.1 5) Shore Hardness: 40 ± 5Sqm2,125.00
52.16Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another enoate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item) (Upto 15 mm thickness at a time).Sqm2,211.00
52.17Removing loose rust from the reinforcement bars by wire brushing, light hammering etc. and applying sulphate and chloride free inorganic single component rust remover Rusticide as approved by Engineer in charge conforming to IS 9077. The rusted surface shall become blackish non rusted colour. After 24 hours of application of rust remover, loose particles shall be removed by brush. Apply one more coat of Rusticide. Apply bonding coat slurry of high performance acrylic polymer - Methyl 2-methylpropenoate copolymer with another innovate as approved by Engineer in charge on entire surface. Mix 1 Kg of acrylic polymer with 0.5 Kg of cement. Finish it with ready to use repair polymer modified mortar based on special cements, formaldehyde based polymer with thixotropy modifying agents as approved by Engineer in charge (The Polymer Modified Mortar (PMM) should attain min. compressive strength of 20 N/mm2 in 1 day and 30 N/mm2 in 7 days) by adding 13 - 16% water by weight of polymer modified mortar for treatment to the damaged RCC members. Add 1 Kg of Migrating Corrosion Inhibiting Admixture as approved by Engineer in charge per 25 Kg bag of polymer modified mortar. After mixing polymer modified mortar, it can be trowel applied or sprayed. When applying by hand, polymer modified mortar must be forced tightly into the substrate to ensure complete contact with the substrate. (If scaffolding is required, same shall be provided and will be paid under relevant item) (15-30 mm thickness at a time).Sqm1,471.00
52.18For Strengthening of concrete RCC, Columns, Beams, Slabs, Foundation etc. Execute the work as follows. Remove dust, laitance, grease, oil, curing compounds, waxes, foreign particles, coatings and disintegrated materials by mechanical means (i.e., blast cleaning). Empty entire pre-packed and pre-weighed contents of ‘B’ Component into pail containing ‘A’ Component. Mix for 30 seconds with a low speed stirrer. (400-600 rpm). After proper mixing of component ‘A’ and ‘B’, now empty entire pre-packed and pre-weighed part ‘C’ component into the mix and using a mechanical stirrer mix all the components for 1-3 minutes with a low speed stirrer (400 to 600 rpm). Caution: Mix only that limited quantity which can be placed within the pot life. Material should be quickly brushed/ poured from pail onto concrete surface to obtain prolonged working life. Inspect the underside for evidence of full depth cracks that may require additional treatment to prevent draining of the resin. Cracks greater than 1/8" width should be repaired individually. Fill 1/8" or larger cracks with loose sand and pour small quantity of mixed 2-(methoxycarbonyl)-1- Propene Resin Sealer Cum Grout as approved by Engineer in charge into the crack, allow to cure. The above Material is spread evenly on the surface as a flood coat with a squeegee or rollers on horizontal and vertical surfaces and allowed to absorb completely into the concrete substrate. Drill injecting holes to a depth of 2 - 4” in concrete depending upon the width of crack, extent of damage and dimension of structural element. Fix the grouting nozzle and inject the mixture of 2-(methoxycarbonyl)-1-Propene Resin Sealer Cum Grout at pressure of 50 - 100 psi. (Rate for fixing nozzle is not included in this item). Low Viscosity, Transparent, Three Component, 2-(methoxycarbonyl)-1-Propene Resin Sealer Cum Grout should have following minimum properties: 1. Viscosity: < 5 cps 2. Flexural Strength (ASTM D-790): 1 day - 17.2 MPa 3. Bond Strength (ASTM C-882): 2 days - 14.4 MPa (Dry Cure); 14 days - 15.8 MPa (Moist cure) 4. Volume Solids %: ~100 It shall be applied as per manufacturer’s specification. (If scaffolding is required, same shall be provided and will be paid under relevant item) (Coatings and Grouting Items shall be separate)KG2,024.00
52.19Providing and applying one coat of thiazolinones (TZ) based Microbial Wall Wash and Anti-rooting Solution treatment as approved by Engineer in charge to entire surface of external wall. At the junction of chajja and wall and also on the parapet wall top, give a coat of anti fungal treatment. Cracks, if any, shall be filled with acrylic polymeric non- shrink crack filler putty as approved by Engineer in charge, before giving waterproofing treatment to the external surfaces. This is followed by one coat of 2-(methoxycarbonyl)-1- propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge, having a non-toxic acrylic polymer liquid and white cement mix in proportion 1:1 by weight with coat interval as 24 hours. Air curing shall be done for 24 hours. Before giving this treatment the entire surface of wall shall be thoroughly cleaned to remove existing paint, dust, dirt, oil etc. After the waterproofing treatment is cured, provide and apply two coats of titanium dioxide based 2-(methoxycarbonyl)-1-propene- butyl-2 propenoate (TMPBP) emulsion, heat insulating, waterproofing exterior coating as approved by Engineer in charge in the desired shade. The inter-coat gap to be 24 hours. The rate shall include complete treatment mentioned above. 100% Acrylic, Decorative, Waterproofing, Heat Insulating, Exterior Coating, Anticarbonation Coating should have following minimum properties: 1. Specific Gravity: 1.3 ± 0.1 at 25°C 2. pH: 7.0 to 10.00 3. Viscosity: 18 to 30 sec. at 25°C by Ford Cup No. B-4 (Dilute 2 parts of product with 1 part of water) (If scaffolding is required, same shall be provided and will be paid under relevant item)Sqm394.00
52.20Providing and fixing zinc alloy based galvanic disk type sacrificial anodes (50 mm dia, 18 mm thick) as approved by Engineer in charge to the reinforcement, that should have a 3 years track record of use in PWD projects, 4 year track record in corrosive region of abroad and pass 500 hours salt spray test as per ASTM B 117. The anode shall be connected to the reinforcement steel by connectors provided with the anode. Sacrificial Galvanic Anode should have following minimum properties: 1. Base: Zinc Alloy 2. Conformance: ASTM B 418 Type II 3. Zinc Mass: Min 40 g per anode 4. Geometry: Disc Type 5. Diameter: 50 mm 5. Height: 18 mm 6. Surface Area: 6751 sq mm It shall be applied as per manufacturers specification. (If scaffolding is required, same shall be provided and will be paid under relevant item)Sqm1,089.00
52.21Make the surface clean of loose particles, dirt, dust, oils, and paints etc. by wire brush. Remove all laitance from surface. On the entire clean surface, apply a coat of Ter polymer of enoates of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) and propenonitrile as approved by Engineer in charge and cement (1:0.25) by spray or ordinary cement brush. Fill up all bug holes with above slurry. Apply slurry generously on entire surface without pinholes. Similar treatment to be given to other block surface immediately. Place coated area of one block over coated area of another block immediately after application. Polymeric bonding agent to be used for AAC Block to AAC Block & CC Brick Block to CC Brick Block should have following minimum properties: 1. Base: Polymeric Emulsion 2. Specific Gravity: 1.03 ± 0.02 3. pH Value: 7.5 - 8 It shall be applied as per manufacturer’s specification. (If scaffolding is required, same shall be provided and will be paid under relevant item)Sqm160.00
52.22It is ready to use inorganic, bio compatible, low viscosity, non hazardous, soil stabilizing two component colloidal silica base chemical grout. Providing and carrying out this grouting to stabilize the strata above the tunnel, foundations, cutting slope stabilization and sub structures by using ultimate fine Nano grout as approved by Engineer in charge. Drill injecting holes to required depth in loose soil strata. Fix the grouting pipes. Grout must be continuously stirred during addition of accelerator and fully mixed to transparent solution prior to grouting into the soil/strata. No white precipitates should remain in the grout mix. This is ultimate fine grouting can be completed by Nano grout. Solvent Free, Inorganic, Hydrophilic, Non-hazardous, Low Viscosity Chemical Grout for Stabilization and Consolidation of Sandy/Silty Soil should have following minimum properties: Grout: (Rate for fixing nozzle is not included in this item). 1) Specific Gravity: 1.2 ± 0.1 2) pH: 11.3 ± 0.1 3) Viscosity in B4 Ford cup at 28°C: 12-15 sec Accelerator: 1) Specific Gravity: 1.07 ± 0.01 2) pH: 7.0 ± 0.1 3) Viscosity in B4 Ford cup at 28°C: 10- 12 sec Sungeogrout Mix: 1) Specific Gravity: 1.2 ± 0.1 2) Viscosity in B4 Ford cup at 28°C: 12-15 sec It shall be applied as per manufacturer’s specification. (If scaffolding is required, same shall be provided and will be paid under relevant item)KG640.00
52.23Waterproofing Treatment to plastered surface of toilet & bathroom walls minimum up to 90 cm (Dado) by using 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Clean the entire surface thoroughly and over this prepared surface, apply three coats of 2- (methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge.While the 3 coat is wet broadcast sand on the surface. Provide 20 mm thick cement plaster in CM 1:3 with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement including all lead, lifts ,curing etc complete. Acrylic Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties: 1. Elongation % (ASTM D412-2016): @ 100% 2. Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3. Specific Gravity: 1.02 ± 0.02 4. Total Solids (ASTM D1644-2012): 43.98 5. Hardness Shore A (ASTM D2240-2015): 82 It shall be applied as per manufacturer’s specification.Sqm450.00
52.24Providing & mixing liquid internal curing compound which is based on water soluble oxyethylene polymer (OEP) for RCC, Shotcrete, mortar .The liquid shall be conforming to AS 3799 -1998 for curing efficiency not less than 90% & capable of improving workability, pumpability, impermeability, full hydration of all types of cement essential for optimum strength development. The dose of liquid shall be average 1.25 % by weight of cement. The liquid is to be mixed with gauging water while mixing the concrete/motar/shortcrete.Litre528.00
52.25Clean the existing surface / terrace thoroughly to remove dirt, loose particles, laitance etc. For emergency waterproofing of existing terrace. Use a vacuum cleaner or high pressure jet or wire brushing as per requirement. Examine the surface closely for any cracks. Fill it with acrylic polymeric non-shrink crack filler putty as approved by Engineer in charge a pure aliphatic, acrylic, polymer modified ready to use paste. After filling, allow the surface to dry for atleast 24 hrs. If the depth of the crack is more than 2-3 mm apply in layers at intervals. Moisten the surface with a water jet one day prior to the application of waterproofing coating. Mix 1 part of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge and 1 part of grey cement by weight using a low speed mechanical stirrer to form slurry lump free consistency. Apply this as a primer coat of 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) membrane as approved by Engineer in charge. Apply the same slurry by roller at 24 hrs interval between the applications of each coat. Extend the coating to parapet walls. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of pure enoate based polymer titanium dioxide based 2-(methoxycarbonyl)-1-propene-butyl-2 propenoate (TMPBP) and 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) of waterproof coating as approved by Engineer in charge on surface. Ensure that no pinholes are let untouched. Allow the membrane to cure for 24-48 hours. Single Component, UV Resistant, Elastomeric, High Build Waterproof Coating (Confirming to DIN 1048) should have following minimum properties: 1) Elongation % (ASTM D 638): @ 400% 2) Tensile Strength (ASTM D 412): 150 psi 3) Water Permeability (DIN 1048): Zero 4) Solids: > 65% 5) pH: 8.5 - 10.5Sqm704.00
52.26Providing Water proofing treatment to old terraces by removing existing treatment, sealing of cracks by non shrink crack fill compound applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion (1 litre polymer : 2 Kg Cement ) to a neatly cleaned and dust free concrete surface and upto 300 mm over parapet wall prepared by removing loose and deposited material with brush and water, followed by a coat of flexible cementious coating eg. MYK-Aqufine U.M., EL Monobond or equivalent as per manufacturer specification after laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover of 20 mm water proof plaster after sufficient curing 40 to 75 mm IPS 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound and polypropylene fibres @ 125 gm per bag of cement within it conforming to IS in pannels making groove 3 to 4 mm wide & 10 mm deep & 3m/4m or as per site condition & filling the joints with polt sulphide sealant after curing, including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry including curing as directed and ponding the surface as directed etc. complete; covering 10 years guarantee against leakproofness on Court Fee Stamp Paper of Rs. 100/-Sqm2,167.00
52.27Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-Sqm1,746.00
52.28Providng Grouting by specially prepared grout of approved make chemical with cement in proportion 1:3.5 (1 part chemical & 3.5 part cement by weight) along wih 50 ml super plasticizer non cracking antiwash high strength polymer cement grout P C grout available in bags or equivalent with proper water for injectable consistency and applying it in the body of structure like slab, beam, column, pillars, deckslab, retaining wall, basement, underground and elevated water storage reservoir concrete and brick wall, crack portion of structure etc. by injectng method, to achieve its original strength including drilling of suitable diameter drills holes at 2 to 4 Nos. per sqm. using caps and nozzle grouting machinery necessary, scaffolding, finishing and covering gurantee of 10 years on court stamp paper of Rs. 100/- and necessary testing etc. complete. (Prior permission of S.E. in writing is necessary before inclusion of this item in estimate)KG404.00

Pricing water proofing against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.

See how estimation works