Maharashtra SOR 2022-23
Structural Strengthening rates
16 structural strengthening items from the Maharashtra Public Works Department (PWD), effective 2022-07-25.
Structural Strengthening rates in the Maharashtra State Schedule of Rates 2022-23 run from ₹80.00 to ₹7,317.00. Transcribed from Maharashtra PWD — State Schedule of Rates 2022-23, effective 25 July 2022. Reference only — verify against the official source before pricing a bid.
16 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| 47.01 | Providing & Applying chemical for cleaning the exposed steel structure, TMT bars, etc. of structure by grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal also removing loose particles, of the area by water jet, (using other mechanical / manual means) and apply on prepared surface of as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturer's specification ( using other manual / mechinical means) after that Providing and applying high abrasive resistant, self curing, UV resistant,impermeable ,high strength, non shrink, Poly Ironite Ceramic Cementatious (PICC) repair mortar resurfacing on concrete surface of thickness up to 10 mm including breaking honey comb area, (using manual/mechanical means) , clean the concrete surface with special chemical clonon with pressure water jet for removing of algae fungi, apply bond coat Kelox water misible epoxy before PICC application with all leads and lifts, Material, Machinery, labour, scaffolding, etc. complete as per specification and as directed by engineer-in-charge. | Sqm | 3,891.00 |
| 47.02 | Providing and grouting the holes by Poly Ceramic Cementitious i.e NicGrout G 06 + 53 grade cement material of as per requirement to reduce the porosity of concrete / Masonry structure and to increase the strength of structure using grouting pipes , grouting m/c, mixer etc and all relevant safety with all leads and lifts, material, machinery, labour, etc. Complete as per specification and as directed by Engineer-in-Charge. | KG | 80.00 |
| 47.03 | Providing and applying high abrasive resistant, UV resistant,impermeable ,self curing,high strength, non shrink, Poly Ironite Ceramic Cementatious (PICC) repair mortar for water proofing on concrete surface with thickness up to 5 mm, , apply bond coat Kelox Water Misible epoxy before PICC application (using manual/mechanical means) and Providing and Applying PCC up to 50 mm thickness for desire slope to drain the water and kept ponded for continuous period of 3 days to detect any seepage / leakage/ dampness if any, the surface then shall be cleared, complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. | Sqm | 1,527.00 |
| 47.04 | PICC Coating for concrete Bridge repair work :-Providing and applying Poly Ironite Ceramic Cementitious (PICC) material of Self curing ,High Abrasion resistant , Non shrink ,High strength,UV resistant, repair mortar coating on bond coat Kelox water missable epoxy of on concrete surface upto 10 mm thickness including Cleaning the concrete surface of bridge by grinding the surface by grinder machine with wire brush /diamond wheel, removing existing loose particles etc. by using grinder, wire brush,breaker machine, water jet(using other mechanical / manual means) also removing of algae fungi by special chemical of clonon etc.complete with all leads and lifts, Material, Machinery, Labour, Scaffolding etc. complete as per specification and as directed by engineer-in-charge. | Sqm | 5,165.00 |
| 47.05 | Removal of Vegitation/Plants:- Removal of entire root inside the bridge portion. Remains of the root shall be treated with special chemical Steripure MBT 20. Top 50 mm shall filled with high strength grout including cost of all material, machinery, labour, scaffolding, etc.as per specification and as directed by Engineer-in-Charge. | Sqm | 1,511.00 |
| 47.06 | Providing & Applying DuraClean- WR for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraGuard - as corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturer's specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. | Sqm | 1,469.00 |
| 47.07 | PICC filling for Honey combing area at concrete surface:-Providing and applying Poly Ironite Ceramic Cementitious (PICC) material of Self cureing ,High Abrasion resistant , Non shrink ,High strength,UV resistant, repair mortar coating on Kelox water missble epoxy of concrete surface fill the honey combing area etc. on tacky primer coat upto 10 mm thickness or as per the surface conditions including Cleaning the concrete surface of bridge by grinding the surface by grinder machine with wire brush /diamond wheel, removing existing loose particles etc. by using grinder, wire brush,breaker machine, water jet(using other mechanical / manual means) also removing of algae fungi by special chemical of clonon. etc.complete with all leads and lifts, Material, Machinery, Labour, Scaffolding etc. complete as per specification and as directed by engineer-in-charge. | Sqm | 5,509.00 |
| 47.08 | Providing and applying Poly Ironite Ceramic Cementitious (PICC) of self curing, a high abrasion resistant, non-shrink, high strength,low porosity, UV resistant repair mortar on Concrete road etc including cleaning the Concrete surface on concrete road by breaking, cleaning with wire brush , removing existing loose particles etc. by using wire brush,breaker machine, air (using other mechanical / manual means) then applying Kelox ( water missible epoxy)of , bond coat on prepared concrete surface for bonding the old surface to new repair mortar etc. as per manufacturer's specification ( using other manual / mechinical means) then apply repair mortar of PICC to fill the concrete surface upto 15 mm coat etc.complete with all leads and lifts, Material, Machinery, Labour etc. complete as per specification and as directed by engineer-in- charge. | Sqm | 5,284.00 |
| 47.09 | Providing and applying Poly Ironite Ceramic Cementitious (PICC) of self curing, a high abrasion resistant, non-shrink, high strength,low porosity, UV resistant repair mortar on Concrete road etc including cleaning the Concrete surface on concrete road by breaking, cleaning with wire brush , removing existing loose particles etc. by using wire brush,breaker machine, air (using other mechanical / manual means) then applying Kelox ( water missible epoxy)of , bond coat on prepared concrete surface for bonding the old surface to new repair mortar etc. as per manufacturer's specification ( using other manual / mechinical means) then apply repair mortar of PICC to fill the concrete surface upto 25 mm coat etc.complete with all leads and lifts, Material, Machinery, Labour etc. complete as per specification and as directed by engineer-in- charge. | Sqm | 7,317.00 |
| 47.10 | Providing and applying Poly Ironite Ceramic Cementitious (PICC) of self curing, a high abrasion resistant, non-shrink,high strength, low porosity, UV resistant coating mortar on existing GSB of 100 mm thickness , get levelled the surface and cure then applying self curing coating PICC mortar for 50 mm thickness after stamp the surface by special concrete stamping mold as per specified texture and colour etc.complete with all leads and lifts, Material, Machinery, Labour etc. complete as per specification and as directed by engineer-in- charge. | Sqm | 3,043.00 |
| 47.12 | Providing & Applying DuraClean- WR - for cleaning the TMT bars, steel structure etc. of structure by Waterjet cleaning/ grinding the surface by grinder machine, wire brush, removing existing corrosion from the metal surface also removing loose particles(using other mechanical / manual means) and apply on prepared surface of DuraCap 2 coats corrosion preventive coat on prepared TMT bars, steel structure,metal surface etc. to protect it from corrosion etc. as per manufacturer's specification ( using other manual / mechinical means) complete as per specification including cost of all materials, machinery, labour, insurance charges as directed by the Engineer in charge. | Sqm | 519.00 |
| 47.15 | Providing and applying 30 mm thick self curing Ceremic Polymer Microconcrete of approved make having Compressive strength above M30, non shrink, impermeable , filling mortar to load carrying R.C.C member in two layers on cleaned concrete surface , including honey comb area (using manual/mechanical means). Mixing mortar of Nicosil C80 and fresh 53 grade cement with required water cement ratio for desired consistency and applying and finishing by manual trawelling , curing after curing initial setting time etc, as per manufacturers specification etc. complete as per specification and as directed by engineer-in- charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper. (Bond coat mentioned below is to be done before coating) | Sqm | 2,429.00 |
| 47.16 | Providing and applying Kelox R 101 (Resin) + Kelox H 404 (Hardner) water misible epoxy of approved make for bonding old concrete to new moratr after mixing slowely in predefined ratio and applying by brush on the surface, when it is tacky then apply the moratr complete as per specification and as directed by engineer-in-charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper | Sqm | 727.00 |
| 47.17 | Corrosion protection of unexposed old reinforcement on non-spalled concrete by Insertion of sustained release Corrosion inhibiting caplets like Powrthrow which protect both anodic & cathodic sites and reduces Corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20-22 mm dia holes into the concrete at a depth of 30-40 mm and inserts to be filled by epoxy sealant EPCO-1010. Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03 % by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120mm & film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi.Spacing of Powrthrow shall be- a) For RCC Columns- 1 Units in a single drilled hole at a spacing of 1m c/c from two opposite faces in staggered fashion b) For RCC Beams- 1 Units in a single drilled hole at a spacing of 1m c/c from two opposite faces in staggered fashion C) RCC Slab- 4 Units in a single drilled hole in 1 sqm area in a grid pattern | Sqm | 1,295.00 |
| 47.18 | Providing protection of unexposed old reinforcement on non spalled concrete by insertion of sustained release corrosion inhibitor caplets like POWRTHROW sustained release Corrosion inhibiting caplets of to protect both anodic & cathodic sites and shall reduce to reduce corrosion potential Ecorr by minimum 80 mV in conductive medium, by drilling 20 mm holes into the concrete at a depth of 25 mm and inserts to be filles by EPCO-PC- Putty. Caplets shall inhibit corrosion inhibition efficiency of 98% (when added 0.03% by weight) against control sample evaluated by Tafel polarization method. Depth of penetration for effective corrosion protection shall be 120 mm and film formation of 20 Microns as evaluated by CSIR-CECRI Karaikudi. | Each | 352.00 |
| 47.19 | Providing and applying Elastomeric, Anti carbonation, Anti corrosive, UV resistant, Solvent based Pure Aliphatic Acrylate System- MONOPOL 456 on the exterior faces of Buildings Protection against ION penetration, carbonation,UV radiations and wethering effect conforming to ASTM D 4541-02 having Electrochemical impedance of 107 Ω and achieving dry film thickness of minimum 200 microns in a primer coat followed by two top coats using brush or spray after complete cleaning & removal of oil, grease or loose particles from the surface etc. complete. | Sqm | 522.00 |
Other chapters in this schedule
- Road Survey and DPR (76)
- Road Sub grade (36)
- Road Sub Base and Base Course (47)
- Road Surfacing Course (12)
- Rigid Pavement (23)
- Road Furniture (155)
- Road Miscellaneous items (34)
- Road Maintenance (39)
- Cross Drainage Works (28)
- Bridge Foundation and Sub Structure (40)
- Bridge : Bored Pile (51)
- Bridge Bearings (6)
- Bridge Super Structure (72)
- Bridge : Bored Pile New Item (18)
- Bridge Maintenance (19)
- Bridge : Well Foundation (24)
- Bridge sub structure and Foundation (28)
- Bored Pile, Well Foundation, sub & Super Structure (5)
- Arch Bridge (8)
- Bridge Repair New Item (46)
- Excavation (35)
- Pile Foundation: Building (57)
- Structural Steel Work (11)
- Plain Cement Concrete (9)
- Reinforced Cement Concrete (53)
- Brick Masonry (20)
- Stone Masonry (13)
- Concrete Block Masonry (9)
- Expansion Joint (11)
- Water Proofing (39)
- Plastering and Pointing (44)
- Paving Flooring and dado (78)
- Wood Finish (11)
- Oil Painting (29)
- Colouring (25)
- Wood Work (26)
- Roofing and Ceiling (57)
- Roofing and Ceiling ( New Item) (16)
- Doors and Windows (110)
- Iron Work (12)
- Water Supply and Sanitary Fitting (213)
- Building Miscellaneous Item (23)
- Building Maintenance (57)
- Flooring (7)
- Plumbing (19)
- Rain water harvesting (9)
- Others (7)
- Coastal (33)
- Block masonary (5)
- Road work (16)
- Accoustic (20)
- Furniture (39)
- PWD persons (28)
- Cubical Toilet (6)
- Building (7)
- bambusa bamboos item (7)
- Bridge repair (13)
- Rebar (29)
- New Item (18)
Pricing structural strengthening against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.
See how estimation works