Skip to main content

Ladakh SOR 2024

Structural Glazing Aluminium Composit Panel rates

5 structural glazing aluminium composit panel items from the Ladakh Public Works (R&B), effective 2024-08-01.

Structural Glazing Aluminium Composit Panel rates in the Ladakh Ladakh Schedule of Rates 2024 run from ₹500.60 to ₹9,624.44. Transcribed from UT of Ladakh, Public Works (R&B) Department — Ladakh Schedule of Rates (LSoR) 2024, Order No.58-LA-PW(R&B) of 2024 dated 24.07.2024, operative from 1 August 2024. Reference only — verify against the official source before pricing a bid.

5 items — scroll the table to browse

DescriptionUnit
30.1Providing and supplying aluminium extruded tubular and other aluminium sections as per thearchitectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T7as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 ofrequired colour and shade as approved by the Engineer-in-Charge. (The item includes cost of materialsuch as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work.Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken forpurpose of paymentKG500.60
30.2Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system ofstructural glazing (with open joints) for linear as well as curvilinear portions of the building for allheights and all levels, includingSqm4,305.85
30.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-7 mm insulated glass (double glazed) vision panel units of size and shape as required and specified,comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade withreflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear floatglass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal(structural silicone sealant) etc. all complete for the required performances, as per the Architecturaldrawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- Charge.The IGUs shall be assembled in the factory/ workshop of the glass processorSqm4,389.28
30.6Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithicfloat glass of approved colour and shade with reflective soft coating on surface # 2 of approved colourand shade so as to match the colour and shade of the IGUs in the vision panels etc.,all complete for therequired performances as specified, as per the Architectural drawings, as per the approved shopdrawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area ofgrooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of releventItem*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, havingproperties as visible Light transmittance (VLT) of 25 to 35%, Light reflection internal 10 to 15%, lightreflection external 10 to 20%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc.. Theproperties of performance glass shall be decided by technical sanctioning authority as per the siterequirementSqm2,888.67
30.8Design supply & installation of suspended Spider Glazing system designed to withstand the windpressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steelof approved manufacturer with glass panel having 12 mm thick clear toughened glass held together withSS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glassfins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainlesssteel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener &anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators toprevent bi- metallic contacts, all complete to perform as per specification and approved drawings. Thecomplete system to be designed to accommodate thermal expansion & seismic movements etc. Thejoints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to befilled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structuraldesigner, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporaryservices all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glassetc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness ofjoints and the portion of Glass panel inside the SS channel shall be measuredSqm9,624.44

Pricing structural glazing aluminium composit panel against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.

See how estimation works