82 repairs to building items from the Ladakh Public Works (R&B), effective 2024-08-01.

Repairs to Building rates in the Ladakh Ladakh Schedule of Rates 2024 run from ₹2.93 to ₹1,94,638.07. Transcribed from UT of Ladakh, Public Works (R&B) Department — Ladakh Schedule of Rates (LSoR) 2024, Order No.58-LA-PW(R&B) of 2024 dated 24.07.2024, operative from 1 August 2024. Reference only — verify against the official source before pricing a bid.

82 items — scroll the table to browse

DescriptionUnit
14.2.1Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-ChargeDoor chowkhatsEach1,769.87
14.2.2Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-ChargeWindow chowkhatsEach1,107.63
14.2.3Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-ChargeClerestory window chowkhatsEach779.04
14.3Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/ Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastenerEach891.71
14.4.1Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-ChargeFor door/ window/ clerestory windowSqm1,111.33
14.5.1Renewing glass panes, with putty and nails wherever necessary including racking out the old puttyFloat glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)Sqm1,560.51
14.5.2Renewing glass panes, with putty and nails wherever necessary including racking out the old puttyFloat glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)Sqm1,835.23
14.6.1Renewing glass panes, with wooden fillets wherever necessaryFloat glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)Sqm2,060.39
14.6.2Renewing glass panes, with wooden fillets wherever necessaryFloat glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)Sqm2,327.98
14.7.1Renewing glass panes and refixing existing wooden filletsFloat glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)Sqm1,713.31
14.7.2Renewing glass panes and refixing existing wooden filletsFloat glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)Sqm1,980.91
14.8.1Supplying and fixing new wooden fillets wherever necessary2nd class teak wood filletsSqm83.84
14.8.2Supplying and fixing new wooden fillets wherever necessaryHollock wood filletsSqm69.94
14.9Renewal of old putty of glass panes (length)Metre53.52
14.10Refixing old glass panes with putty and nailsSqm695.79
14.11Fixing old glass panes with wooden fillets (excluding cost of fillets)Sqm637.57
14.12Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps completeSqm530.46
14.13Regrading terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-in-ChargeSqm720.00
14.14.1Replacing sand stone slabs in roofing, laid in cement mortar 1:4 (1 cement: 4 coarse sand), including necessary repairs and cement pointing with same mortar complete, including disposal of rubbish to dumping ground, all complete as per direction of Engineer-in-ChargeRed/ white sand stone slabs 30 to 50 mm thickSqm1,354.33
14.15.1Renewing wooden battens in roofs, including making good the and painting with oil type wood preservative of approved brand and complete, including removal of rubbish to the dumping ground, all per direction of Engineer-in-ChargeSal wood battensCum1,46,384.44
14.16.1.1Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge — Not exceeding 4.00 metres in lengthSal wood beamsCum1,52,100.13
14.16.1.2Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge — Not exceeding 4.00 metres in lengthHollock wood beamsCum83,288.67
14.16.2.1Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge — Above 4.00 metres and upto 5.00 metres lengthSal wood beamsCum1,54,331.76
14.16.2.2Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge — Above 4.00 metres and upto 5.00 metres lengthHollock wood beamsCum79,239.00
14.17Raking out joints in lime or cement mortar and preparing the surface for repointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-ChargeSqm58.97
14.19Taking out wind ties from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within compound and stackingKG4.80
14.20Fixing of old wind tie with new fittings including painting two or more coats with anticorrosive bitumastic paint of approved brand & manufacturer over and including priming coat of ready mixed zinc chromate yellow primer of approved brandMetre7.93
14.21Renewing bottom rail and/or top runner of collapsible gate including making good all damages and applying priming coat of zinc chromate yellow primer of approved brand and manufacturerKG276.92
14.24Mud mortar made with local clay good earthCum1,042.66
14.25Brick work with common burnt clay bricks of class designation 7.5 in mud mortarCum8,333.72
14.26.1.1Providing and fixing 25 mm thick shutters for cup board etc — Panelled or panelled & glazed shuttersSuperior class teak wood including nickel plated bright finished M.S. piano piano hinges with necessary screwsSqm5,951.86
14.26.1.2Providing and fixing 25 mm thick shutters for cup board etc — Panelled or panelled & glazed shuttersIst class teak wood including nickel plated bright finished M.S. piano hinges with necessary screwsSqm5,873.46
14.26.2.1Providing and fixing 25 mm thick shutters for cup board etc — Glazed shuttersSuperior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screwsSqm6,090.71
14.26.2.2Providing and fixing 25 mm thick shutters for cup board etc — Glazed shuttersIst class teak wood including nickel plated bright finished M.S. piano hinges with necessary screwsSqm6,006.28
14.27.1Providing and fixing plain jaffri door and window shutters including bright or/ and black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart beading complete with:(frames to be paid separately), including fixing 50x12 mmSecond class teak woodSqm6,452.73
14.28.1Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete20 mm diametreSqm405.53
14.28.2Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete25 mm diametreMetre506.54
14.29Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windowsKG130.09
14.30.1Providing joists (karries) including hoisting, fixing in position and applying wood preservative on unexposed surface etc. complete withSal woodCum1,94,638.07
14.30.2Providing joists (karries) including hoisting, fixing in position and applying wood preservative on unexposed surface etc. complete withHollock woodCum71,344.82
14.31.1Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete150 mmEach884.74
14.31.2Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete125 mmEach647.16
14.31.3Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete100 mmEach613.02
14.32.1Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete150 mmEach1,002.82
14.32.2Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete125 mmEach867.67
14.32.3Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete100 mmEach803.59
14.33.1Providing and fixing bright finished brass flush bolts with necessary brass250 mmEach291.64
14.33.2Providing and fixing bright finished brass flush bolts with necessary brass150 mmEach253.69
14.33.3Providing and fixing bright finished brass flush bolts with necessary brass100 mmEach186.47
14.34Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness completeEach338.41
14.35.1Providing and fixing bright finished brass hard drawn hooks and eyes300 mmEach127.19
14.35.2Providing and fixing bright finished brass hard drawn hooks and eyes250mmEach123.21
14.35.3Providing and fixing bright finished brass hard drawn hooks and eyes200 mmEach94.33
14.35.4Providing and fixing bright finished brass hard drawn hooks and eyes150 mmEach75.70
14.35.5Providing and fixing bright finished brass hard drawn hooks and eyes100 mmEach66.45
14.36Providing and fixing bright finished brass fan light pivot with necessary brass screws etc. completeEach55.93
14.37Providing and fixing 300 mm long bright finished brass chain with hook for fan light including necessary brass screws etc. completeEach88.12
14.38Providing and fixing bright finished brass quadrant stay 300 mm long with necessary brass screws etc. completeEach206.20
14.39Providing and fixing bright finished brass helical door spring (superior quality)Each511.72
14.40.1Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete125x70x4 mm (ordinary type)Each219.87
14.40.2Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete100x70x4 mm (ordinary type)Each192.96
14.40.3Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete75x65x4 mm (heavy type)Each222.52
14.40.4Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete75x40x2.5 mm (ordinary type)Each131.90
14.40.5Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete50x40x2.5 mm (ordinary type)Each56.27
14.41Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. completeEach355.66
14.72Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after.The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be doneSqm330.22
14.73Providing and fixing bright finished brass casement window stays to windows/ ventilators with necessary welding and machine screws etc.fasteners or peg completeKG636.88
14.79Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-chargeEach379.17
14.80.1Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in chargeLong pattern W.C Pan of size 580x440 mmEach4,280.42
14.80.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in chargeOrissa pattern W.C Pan of size 580x440 mmEach5,114.80
14.81Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-chargeEach295.91
14.82Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-ChargeEach109.73
14.83Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-ChargeSqm2.93
14.84Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wallMetre3.91
14.85Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-chargeEach420.47
14.86Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/ 25 conforming to IS: 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layer prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement: 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement: 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately)Sqm730.30
14.87Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS: 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement: 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately)Sqm472.39
14.88Providing and laying in situ seven course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS: 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement: 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately)Sqm819.12
14.89.1Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 2 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parametres of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane2mm (for corrugated roof sheets)Sqm492.56
14.90.1Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parametres of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane3 mm thickSqm595.84
14.91.1Providing and laying APP (Atactic Polypropylene modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parametres of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane3 mm thickSqm630.27
14.92Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendationSqm126.19

Pricing repairs to building against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.

See how estimation works