Skip to main content

Chhattisgarh SOR 2026

Cement Concrete (Plain and Reinforced) rates

24 cement concrete (plain and reinforced) items from the Chhattisgarh Public Works Department (PWD), effective 2026-06-10.

Cement Concrete (Plain and Reinforced) rates in the Chhattisgarh Building Schedule of Rates 2026 run from ₹4.00 to ₹5,376.00. Transcribed from Chhattisgarh PWD — Modified Building SOR, 10 June 2026. Reference only — verify against the official source before pricing a bid.

24 items — scroll the table to browse

DescriptionUnit
3.4Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinthCum83.00
3.5Providing and laying pre-stressed cement concrete of M-35 grade in superstructure including form work but excluding reinforcement complete as per drawing and specifications and IS: 1343-2012Cum5,376.00
3.6Providing and laying High tensile steel wires/ strands at any level including all accessories i.e. sheathing duct, tube anchorage set, and stressing, stressing operations and grouting with cement complete as per drawing and technical specificationsKG123.00
3.7Providing and mixing in cement concrete, triangular polyester fiber Recron 3s (Anti-shrinkage Admixture) of 12 mm length of approved make like Reliance industries Ltd etc. in proportion as recommended by manufacturerKG311.00
3.8Extra for providing and fixing expanded metal mesh of size 20mm x60mm and strands 3.0mm wide, 1.6 mm thick, weighting 2.64 kg. per sqm for encasing of rolled steel section in beams, columns and grillages but excluding cost of hangersSqm326.00
3.9Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement: 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement: 3 coarse sand) but excluding reinforcementCum399.00
3.10Extra for laying PCC/ RCC, in or under water or liquid mud including cost of pumping or bailing out of water and removing slush etc. completeCum222.00
3.11Extra for laying PCC/ RCC, in or under foul conditionsCum82.00
3.12.1Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.Thermo-Mechanically treated bars FE 415KG46.00
3.12.2Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.Thermo-Mechanically treated bars FE 500DKG46.00
3.12.3Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.Thermo-Mechanically treated bars FE 550DKG47.00
3.12.4Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.Cold twisted bar / Hot rolled deformed steelKG45.00
3.13Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded crushed stone aggregate 20mm nominal size) including form workCum3,601.00
3.14Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturerKG37.00
3.15Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oilSqm79.00
3.16Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded crushed stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with sand including finishing the top smoothSqm232.00
3.17Providing and laying 25mm thick eves board/ facia made with cement mortar 1:3 (1 cement: 3 coarse sand) and chicken mesh including cost of form work required but excluding steel reinforcementSqm652.00
3.18Providing and filling in position, blown bitumen in expansion joints per cm. depth and per cm widthMetre4.00
3.19Providing and fixing in position copper plate as per design for expansion jointsKG570.00
3.20Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatmentSqm1,187.00
3.22Providing and fixing 6 mm thick asbestos sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatmentSqm454.00
3.24.1Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. The application shall be got done through the authorised applicator of the manufacture of compoundFor gap upto 25 mm wideMetre442.00
3.24.2Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. The application shall be got done through the authorised applicator of the manufacture of compoundFor gap 40 mm wideMetre818.00
3.24.3Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. The application shall be got done through the authorised applicator of the manufacture of compoundFor gap 50 mm wideMetre1,187.00

Pricing cement concrete (plain and reinforced) against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.

See how estimation works