Pumps rates

172 pumps items from the Madhya Pradesh Public Health Engineering Department (PHED), effective 2023-09-01.

Pumps rates in the Madhya Pradesh Unified Schedule of Rates 2023 run from ₹7,330.00 to ₹11,90,135.00. Transcribed from Madhya Pradesh PHED — Unified Schedule of Rates for Water Supply, Sewerage and Allied Works, in force from 1 September 2023. Reference only — verify against the official source before pricing a bid.

172 items — scroll the table to browse

DescriptionUnit
11.1.1Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope0.5 HP Head Mt. 46-13 Discharge LPM 10-55Each13,760.00
11.1.2Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 35-15 Discharge LPM 40-125Each14,896.00
11.1.3Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 61-18 Discharge LPM 25-90Each14,960.00
11.1.4Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 74 - 21 Discharge LPM 15-55Each15,936.00
11.1.5Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 91-28 Discharge LPM 10-45Each17,336.00
11.1.6Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 42 - 17 Discharge LPM 65-150Each17,696.00
11.1.7Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 56-21 Discharge LPM 40-125Each18,802.00
11.1.8Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5HP Head Mt. 84-26 Discharge LPM 25-90Each18,821.00
11.1.9Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 114-33 Discharge LPM 15-55Each19,590.00
11.1.10Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 130-14 Discharge LPM 10-45Each20,303.00
11.1.11Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 56- 16 Discharge LPM 65-205Each19,476.00
11.1.12Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 77-30 Discharge LPM 40-125Each19,656.00
11.1.13Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 114-36 Discharge LPM 25-90Each21,216.00
11.1.14Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 147-42Discharge LPM 15-55Each21,900.00
11.1.15Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 163-58Discharge LPM 10-45Each23,320.00
11.1.16Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 84-23Discharge LPM 65-205Each22,580.00
11.1.17Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 119-45 Discharge LPM 40-125Each23,020.00
11.1.18Supplying & Installation of Energy efficient Three Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 119-45 Discharge LPM 25-90Each23,340.00
11.2.1Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope0.5 HP Head Mt. 46-13 Discharge LPM 10-55Each18,921.00
11.2.2Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 35-15 Discharge LPM 40-125Each20,392.00
11.2.3Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 61-18 Discharge LPM 25-90Each20,790.00
11.2.4Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 74 - 21 Discharge LPM 15-55Each21,399.00
11.2.5Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1 HP Head Mt. 91-28 Discharge LPM 10-45Each21,622.00
11.2.6Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 42 - 17 Discharge LPM 65-150Each22,513.00
11.2.7Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 56-21 Discharge LPM 40-125Each22,682.00
11.2.8Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5HP Head Mt. 84-26 Discharge LPM 25-90Each23,555.00
11.2.9Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 114-33 Discharge LPM 15-55Each24,114.00
11.2.10Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope1.5 HP Head Mt. 130-14 Discharge LPM 10-45Each25,102.00
11.2.11Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 56- 16 Discharge LPM 65-205Each24,955.00
11.2.12Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 77-30 Discharge LPM 40-125Each25,548.00
11.2.13Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 114-36 Discharge LPM 25-90Each26,159.00
11.2.14Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 147-42Discharge LPM 15-55Each27,099.00
11.2.15Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope2 HP Head Mt. 163-58Discharge LPM 10-45Each27,897.00
11.2.16Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 84-23Discharge LPM 65-205Each30,727.00
11.2.17Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 119-45 Discharge LPM 40-125Each32,507.00
11.2.18Supplying & Installation of Energy efficient Five Star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 119-45 Discharge LPM 25-90Each33,109.00
11.3.1Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 55-7 Discharge LPM 60-510Each37,528.00
11.3.2Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 55-13 Discharge LPM 120-510Each44,470.00
11.3.3Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 83-82 Discharge LPM 60-270Each47,725.00
11.3.4Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 101-40 Discharge LPM 60-270Each49,349.00
11.3.5Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 117-31 Discharge LPM 60-240Each55,090.00
11.3.6Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 129-52 Discharge LPM 60-270Each59,518.00
11.3.7Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 138-60 Discharge LPM 60-270Each60,485.00
11.3.8Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope10 HP Head Mt. 147-64 Discharge LPM 60-270Each70,518.00
11.3.9Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope10 HP Head Mt. 184-80 Discharge LPM 60-270Each74,061.00
11.3.10Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope12.5 HP Head Mt. 45-315 Discharge LPM 330-50Each78,541.00
11.3.11Supplying & Installation of Energy efficient five star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6" tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope15 HP Head Mt. 102-254 Discharge LPM 300-100Each88,553.00
11.4.1Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope3 HP Head Mt. 55-7 Discharge LPM 60-510Each33,775.00
11.4.2Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 55-13 Discharge LPM 120-510Each40,023.00
11.4.3Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 83-82 Discharge LPM 60-270Each42,953.00
11.4.4Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope5 HP Head Mt. 101-40 Discharge LPM 60-270Each44,414.00
11.4.5Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 117-31 Discharge LPM 60-240Each49,581.00
11.4.6Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 129-52 Discharge LPM 60-270Each53,566.00
11.4.7Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope7.5 HP Head Mt. 138-60 Discharge LPM 60-270Each54,437.00
11.4.8Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope10 HP Head Mt. 147-64 Discharge LPM 60-270Each63,466.00
11.4.9Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope10 HP Head Mt. 184-80 Discharge LPM 60-270Each66,655.00
11.4.10Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope12.5 HP Head Mt. 45-315 Discharge LPM 330-50Each70,687.00
11.4.11Supplying & Installation of Energy efficient Three star BEE rating ISI Marked required capacity of Three Phase, 50 Hz, 415V, deep well submersible pump Steel body, suitable for 6"tube well with Control Panel Starter suitable for Submersible pump with dry run protection, single phase preventer, connections, including 3 mtr. submersible flat cable ISI marked 3 core copper wire, length equal to head of the pump at duty point + 3mtr. in single or double run (as per requirement of the set/control panel. The size of the cable should be so selected that voltage drop at motor terminal does not exceed the limit of the rated voltage) clamps, bore cap etc. as required as per specifications but excluding pipe, SS/ Nylon wire rope15 HP Head Mt. 102-254 Discharge LPM 300-100Each79,698.00
11.8.1Supplying and Installation of approved Make required capacity single phase, 50 Hz, 220V, Centrifugal Mono-block pump self priming, with Starter, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable1 H.P. Head Mt. 6-30, Discharge LPH 2400-900Each11,803.00
11.8.2Supplying and Installation of approved Make required capacity single phase, 50 Hz, 220V, Centrifugal Mono-block pump self priming, with Starter, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable1 H.P. Head Mt. 21-45, Discharge LPH 1800-400 (Domestic Model)Each7,330.00
11.9.1Supplying & Installation of approved Make required capacity single phase, 50 Hz, 240V, Centrifugal Mono-block pump, with Starter, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable1.0 H.P. Head Mt. 3-24, Discharge LPH 27000-1500Each11,315.00
11.9.2Supplying & Installation of approved Make required capacity single phase, 50 Hz, 240V, Centrifugal Mono-block pump, with Starter, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable1.5 H.P. Head Mt. 3-21, Discharge LPH 39600-6000Each13,592.00
11.9.3Supplying & Installation of approved Make required capacity single phase, 50 Hz, 240V, Centrifugal Mono-block pump, with Starter, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable2.0 H.P. Head Mt. 3-18, Discharge LPH 48600-3000Each15,088.00
11.10.1Supplying & Installation of approved Make required capacity 3 phase, 50 Hz, 415V, Centrifugal Monoblock pump, with Starter, i/c single phase preventor, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable3.0 H.P. Head Mt. 6-15, Discharge LPH 740-465Each19,076.00
11.10.2Supplying & Installation of approved Make required capacity 3 phase, 50 Hz, 415V, Centrifugal Monoblock pump, with Starter, i/c single phase preventor, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable5.0 H.P. Head Mt. 6-33, Discharge LPH 1380-450Each23,370.00
11.10.3Supplying & Installation of approved Make required capacity 3 phase, 50 Hz, 415V, Centrifugal Monoblock pump, with Starter, i/c single phase preventor, connections, base channel foundation etc. as required as per specifications but excluding Pipe and connection cable7.5 H.P. Head Mt. 24-37, Discharge LPH 780-320Each29,917.00
11.11.1Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, including submersible flat cable ISI marked 3 core copper wire of suitable size, SS/ Nylon wire rope, clamps etc. but excluding pipe and connection cable3.0 H.P. Head Mt. 15-24, Discharge LPH 615-195Each22,252.00
11.11.2Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, including submersible flat cable ISI marked 3 core copper wire of suitable size, SS/ Nylon wire rope, clamps etc. but excluding pipe and connection cable5.0 H.P. Head Mt. 15-24, Discharge LPH 930-420Each23,917.00
11.12.1Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 20 to 30 LPS and head 20 to 30 MEach1,32,135.00
11.12.2Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 20 to 30 LPS and head 31 to 40 MEach1,32,135.00
11.12.3Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 20 to 30 LPS and head 41 to 50 MEach1,48,350.00
11.12.4Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 20 to 30 LPS and head 51 to 60 MEach1,48,350.00
11.12.5Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 20 to 30 LPS and head 61 to 70 MEach1,48,350.00
11.12.6Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 31 to 40 LPS and head 20 to 30 MEach1,56,170.00
11.12.7Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 31 to 40 LPS and head 31 to 40 MEach1,56,170.00
11.12.8Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 31 to 40 LPS and head 41 to 50 MEach1,75,145.00
11.12.9Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 31 to 40 LPS and head 51 to 60 MEach2,21,720.00
11.12.10Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 31 to 40 LPS and head 61 to 70 MEach2,32,875.00
11.12.11Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 41 to 50 LPS and head 20 to 30 MEach1,75,145.00
11.12.12Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 41 to 50 LPS and head 31 to 40 MEach1,75,145.00
11.12.13Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 41 to 50 LPS and head 41 to 50 MEach1,89,405.00
11.12.14Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 41 to 50 LPS and head 51 to 60 MEach2,45,525.00
11.12.15Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 41 to 50 LPS and head 61 to 70 MEach2,45,525.00
11.12.16Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 51 to 60 LPS and head 20 to 30 MEach2,02,285.00
11.12.17Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 51 to 60 LPS and head 31 to 40 MEach2,02,285.00
11.12.18Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 51 to 60 LPS and head 41 to 50 MEach2,34,945.00
11.12.19Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 51 to 60 LPS and head 51 to 60 MEach2,83,705.00
11.12.20Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 51 to 60 LPS and head 61 to 70 MEach2,83,705.00
11.12.21Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 61 to 70 LPS and head 20 to 30 MEach2,02,285.00
11.12.22Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 61 to 70 LPS and head 31 to 40 MEach2,02,285.00
11.12.23Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 61 to 70 LPS and head 41 to 50 MEach2,34,945.00
11.12.24Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 61 to 70 LPS and head 51 to 60 MEach2,83,705.00
11.12.25Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 61 to 70 LPS and head 61 to 70 MEach2,83,705.00
11.12.26Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 71 to 80 LPS and head 20 to 30 MEach2,02,285.00
11.12.27Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 71 to 80 LPS and head 31 to 40 MEach2,18,385.00
11.12.28Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 71 to 80 LPS and head 41 to 50 MEach2,76,805.00
11.12.29Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 71 to 80 LPS and head 51 to 60 MEach2,76,805.00
11.12.30Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 71 to 80 LPS and head 61 to 70 MEach3,48,565.00
11.12.31Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 81 to 90 LPS and head 20 to 30 MEach2,97,390.00
11.12.32Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 81 to 90 LPS and head 31 to 40 MEach2,97,390.00
11.12.33Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 81 to 90 LPS and head 41 to 50 MEach3,42,815.00
11.12.34Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 81 to 90 LPS and head 51 to 60 MEach3,96,635.00
11.12.35Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 81 to 90 LPS and head 61 to 70 MEach3,96,635.00
11.12.36Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 91 to 100 LPS and head 20 to 30 MEach3,67,080.00
11.12.37Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 91 to 100 LPS and head 31 to 40 MEach4,15,380.00
11.12.38Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 91 to 100 LPS and head 41 to 50 MEach5,20,375.00
11.12.39Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 91 to 100 LPS and head 51 to 60 MEach5,56,485.00
11.12.40Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 91 to 100 LPS and head 61 to 70 MEach6,08,120.00
11.12.41Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 101 to 120 LPS and head 20 to 30 MEach3,71,105.00
11.12.42Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 102 to 120 LPS and head 31 to 40 MEach4,52,525.00
11.12.43Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 103 to 120 LPS and head 41 to 50 MEach5,56,485.00
11.12.44Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 104 to 120 LPS and head 51 to 60 MEach6,08,120.00
11.12.45Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 105 to 120 LPS and head 61 to 70 MEach7,78,665.00
11.12.46Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 121 to 140 LPS and head 20 to 30 MEach4,18,485.00
11.12.47Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 121 to 140 LPS and head 31 to 40 MEach5,47,975.00
11.12.48Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 121 to 140 LPS and head 41 to 50 MEach5,95,125.00
11.12.49Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 121 to 140 LPS and head 51 to 60 MEach6,37,560.00
11.12.50Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 121 to 140 LPS and head 61 to 70 MEach9,20,690.00
11.12.51Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 141 to 160 LPS and head 20 to 30 MEach5,81,440.00
11.12.52Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 141 to 160 LPS and head 31 to 40 MEach5,81,440.00
11.12.53Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 141 to 160 LPS and head 41 to 50 MEach6,37,560.00
11.12.54Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 141 to 160 LPS and head 51 to 60 MEach6,79,535.00
11.12.55Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 141 to 160 LPS and head 61 to 70 MEach9,20,690.00
11.12.56Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 161 to 180 LPS and head 20 to 30 MEach5,73,505.00
11.12.57Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 161 to 180 LPS and head 31 to 40 MEach5,81,440.00
11.12.58Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 161 to 180 LPS and head 41 to 50 MEach5,81,440.00
11.12.59Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 161 to 180 LPS and head 51 to 60 MEach7,44,280.00
11.12.60Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 161 to 180 LPS and head 61 to 70 MEach9,65,080.00
11.12.61Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 181 to 200 LPS and head 20 to 30 MEach5,73,505.00
11.12.62Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 181 to 200 LPS and head 31 to 40 MEach7,06,445.00
11.12.63Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 181 to 200 LPS and head 41 to 50 MEach7,52,905.00
11.12.64Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 181 to 200 LPS and head 51 to 60 MEach9,33,455.00
11.12.65Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 181 to 200 LPS and head 61 to 70 MEach9,65,080.00
11.13.1Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 201 to 220 LPS and head 20 to 30 MEach6,38,710.00
11.13.2Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 201 to 220 LPS and head 31 to 40 MEach7,02,075.00
11.13.3Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 201 to 220 LPS and head 41 to 50 MEach9,33,455.00
11.13.4Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 201 to 220 LPS and head 51 to 60 MEach9,65,080.00
11.13.5Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 201 to 220 LPS and head 61 to 70 MEach10,01,190.00
11.13.6Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 221 to 240 LPS and head 20 to 30 MEach6,42,850.00
11.13.7Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 221 to 240 LPS and head 31 to 40 MEach7,31,400.00
11.13.8Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 221 to 240 LPS and head 41 to 50 MEach9,39,550.00
11.13.9Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 221 to 240 LPS and head 51 to 60 MEach9,71,865.00
11.13.10Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 221 to 240 LPS and head 61 to 70 MEach10,01,190.00
11.13.11Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 241 to 260 LPS and head 20 to 30 MEach6,86,435.00
11.13.12Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 241 to 260 LPS and head 31 to 40 MEach7,40,255.00
11.13.13Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 241 to 260 LPS and head 41 to 50 MEach9,45,185.00
11.13.14Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 241 to 260 LPS and head 51 to 60 MEach10,01,190.00
11.13.15Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 241 to 260 LPS and head 61 to 70 MEach10,13,380.00
11.13.16Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 261 to 280 LPS and head 20 to 30 MEach6,99,775.00
11.13.17Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 261 to 280 LPS and head 31 to 40 MEach7,90,855.00
11.13.18Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 261 to 280 LPS and head 41 to 50 MEach9,45,185.00
11.13.19Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 261 to 280 LPS and head 51 to 60 MEach10,01,190.00
11.13.20Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 261 to 280 LPS and head 61 to 70 MEach10,13,380.00
11.13.21Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 281 to 300 LPS and head 20 to 30 MEach6,99,775.00
11.13.22Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 281 to 300 LPS and head 31 to 40 MEach7,90,855.00
11.13.23Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 281 to 300 LPS and head 41 to 50 MEach9,71,865.00
11.13.24Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 281 to 300 LPS and head 51 to 60 MEach10,13,380.00
11.13.25Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 281 to 300 LPS and head 61 to 70 MEach10,82,150.00
11.13.26Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 301 to 325 LPS and head 20 to 30 MEach7,32,895.00
11.13.27Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 301 to 325 LPS and head 31 to 40 MEach8,26,045.00
11.13.28Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 301 to 325 LPS and head 41 to 50 MEach11,07,105.00
11.13.29Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 301 to 325 LPS and head 51 to 60 MEach11,32,175.00
11.13.30Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 301 to 325 LPS and head 61 to 70 MEach11,90,135.00
11.13.31Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 326 to 350 LPS and head 20 to 30 MEach7,50,835.00
11.13.32Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 326 to 350 LPS and head 31 to 40 MEach8,62,040.00
11.13.33Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 326 to 350 LPS and head 41 to 50 MEach11,07,105.00
11.13.34Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 326 to 350 LPS and head 51 to 60 MEach11,90,135.00
11.13.35Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 326 to 350 LPS and head 61 to 70 MEach11,90,135.00
11.13.36Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 351 to 400 LPS and head 20 to 30 MEach8,30,185.00
11.13.37Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 351 to 400 LPS and head 31 to 40 MEach8,98,955.00
11.13.38Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 351 to 400 LPS and head 41 to 50 MEach11,32,175.00
11.13.39Supply, delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Horizontal Centrifugal Split Casing pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts etc. complete with all respect as per the specificationDischarge 351 to 400 LPS and head 51 to 60 M SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) Standard Schedule of Rates (SOR) of SCADA / PLC/ INSTRUMENTS for Monitoring & Control various components of water supply scheme The SCADA system shall be of highest reliability & based on the state of the art technology. It shall be capable of Monitoring & Controlling of Various components of Water Supply Scheme wired & wirelessly like Intake/Jack Well, WTP, Raw & Clear Water Pump Houses, MBR, BPT, Service reservoir, etc. The SCADA system is capable of Collecting, Storing, Displaying and Analysing data as per requirement. The SCADA System consist of a number of sub system like Hardware, Software, equipment like RTU, computers and other communication interface devices. SCADA system mainly comprises of: 1. SCADA System: a. Operator & Engineering work station (Server), b. Remote Station Communication Link, c. Printer 2. Programmable logic controller (PLC) a. Main PLC control panel at centralized control panel b. RF Trans – Receiver controller at clarifier unit for wireless communication c. Remote terminal unit (RTU) at Pump Houses Well, OHT, MBR, BPT etc 3. Field Instruments a. Monitoring & Control server Unit at Master Control Center. b. Level Instrument- Ultrasonic /Radar Type c. Flow Instrument- Electromagnetic Flow meter d. Pressure Instrument e. Quality Analysers (Residual Chlorine, Turbidity, pH etc) f. Rate of Flow (ROF) g. Energy Monitoring h. Loss of Head (by Filter bed Level Measurement) SCADA SYSTEM Master Control Station Main PLC (Programable Logic Control) Panel Control Desk SCADA Server Operator Work Station (OWS) Engineering Work Station (EWS) Uninteruptted Power Supply (UPS) Communication Interfrace device (Earthernet, Modeam, Broadband Connection With IP Address) 55" Monitor for Process monitoring Printer for Reports Water Treatment Plant PLC PLC Panel Filetrbed Control System (Actuator, ROF & LOH) Control of Backwash, Blower, Chemical Clarifier Control Through RF communication Quality Analyser (Residul, Chlorine, pH, Turbidity) Communication Interfrace device (Eathernet) Pump House (Raw water, HSC/VT Pump ON/OFF Control & monitoring Water, Intermediate) Remote Flow Monitoring Terminal Unit (RTU) Pressure Monitoring Reservoir Level Monitoring Energy Parameter Monitoring (Voltage, Current, Energy Consumption, PF) Human Machine Interface (HMI) GPRS Modem Service Reserviori, BPT & MBR Programable Logic Controller (PLC) Remote Terminal Unit (RTU) Reservoir Level Monitoring Flow Measurement Controlling of Flow Control Valve Quality Analyser (Residual Chlorine) System Architecture System Architecture Tender Specifications of PLC – SCADA systemfor Water Supply Scheme Programmable Logic Controller (PLC) for WTP General The Control System is dedicated micro processors based automation control system. Its function isto control and monitors the whole process behavior at the water treatment plant in real time. The PLC is needed in order to ensure the process behaviors and performance at the facilities is complied with the process design and control philosophy accordingly. The process design and control philosophy is pre-determined and will be provided during the detail engineering phase by the end user and or consultant. The objective of the control system is to permit the operator to start-up, run and shutdown the production facilities in the water treatment plant with certain parameters and conditions to ensure that the final water product quality is in accordance with the pre- determined standard and the quantity of water products also meets the intended plant design. The final quality of the water will be automatically and constantly monitored, the water which does not comply with the specifications cannot be delivered at any point in time, and will be automatically diverted to the discharge channels. In the normal water treatment plant operation, the process control system shall be completely run in automatic mode requiring limited operator action. Automation and manual operation mode shall be available as an option or selectable mode, the operator, according to his/her access level, can easily change the operation mode at any time accordingly. The control system consists of: • Main controller module • Communication modules • Power supply module • IO modules • Interface modules • Racks or backplanes Central Processor Unit (CPU) for PLC System The main processor module (CPU module) at the controller level shall be in hot standby configuration. One of the processor module act as a primary controller and the other one act as the hot standby module and always be ready to take control if something wrong with the primary CPUmodule. The changeover from primary to the hot standby controller shall be bump less must not affect the controlled process. The hot standby configuration hardware shall be based on two separate identical hardware configuration set. It means the primary and the hot standby controller modules shall be located at two separate back planes with identical hardware. Two back planes are configured with identical hardware, software and firmware. The Hot-standby function must be the inherent properties at the processor operating system level. User programming workaround for redundancy functionality, for example switch over function, will not be acceptable. The synchronizing between the primary and hot standby controllers shall utilize a dedicated synch link port at the CPU module with 1 Gbps transmission speed and shall be available in FO cable or TP copper cable. The CPU module shall also have the integrated communication functionality port for communication with the IO drop communication modules at the IO rack. The communication with IO modules has to be handled by the CPU module. The system shall not require a special module for communication with the IO drop module at the IO rack. The microprocessor of the CPU module shall be based on SPEAr 32 bit dual core multifunction ARM microprocessor architecture runts at 600 Mhz and shall carry the latest error correction (ECC) technology. The microprocessor shall implement the execution of the logic application program in one core and in parallel handle the communication in another core. This separation execution result the faster code execution and bring down the scan time to minimum. The Hot Standby system shall detect a switchover causal event within 15 ms. the time to complete a switchover time shall below 15 ms and shall be bumpless. After the switchover, the former hot standby controller becomes the primary. The CPU module shall have a real time clock with 1 ms resolution. The accuracy of the real-time clock shall be maintained for 4 week when the CPU power is turned off when the operational temperature is below 45o C. The real time clock shall be enabled to: • provide the current date and time • display the date and time of the last application shut-down The CPU module shall be able to be configured as NTP master. The real time clock of the CPU module is used as a time reference in the NTP services. All the node in the Ethernet will use the CPU module time as a time reference for synchronization. The real time clock of the CPU module shall be able to be synchronized with the external time server through the NTP protocol. In this configuration the CPU module is act as the NTP client. Memory and Data Storage The CPU module shall have integrated flash memory using NAND Flash technology on its motherboard to back up the application, keep the data intact and general context of the controller. The NAND flash technology does not required battery and provides a long storage period in the ideal working condition. The CPU module shall have total 8 Mb internal memory capacity for programming process application and data storage. The data capacity for transfer data from primary CPU module to the hot standby CPU module is 4096 Kb. The CPU module shall also has the optional 4 GB SD card to double the storage capacity and as a storage backup. This optional SD card is using the same technology NAND Flash. The removable cartridge / SD card shall be of industrial grade and from the same manufacturer of the processor. Integrated Communication Port The main processor module shall have the integrated ports: Mini-B USB port The Mini-USB port is a high speed mini-B USB connector version 2.0 (480 Mbps) that can be used to connect with the engineering workstation. The mini USB port is for the first time program download and to assign the desired IP address. RJ-45 Ethernet Service Port The RJ-45 Service port can be used for: • Access the diagnostics web server • Communicate with engineering workstation • Communicate with other system RJ-45 Dual Port Ethernet IO Network The RJ-45 dual port Ethernet IO network is for communication with the remote IO modules. The Ethernet port shall support the ring topology with the RSTP protocol to ensure the 50 ms recovery time, in case there is a break in line at the IO ring connection. Synchronization port The port is used for synchronizing link between the Primary CPU module and the Standby CPU module. The CPU module shall have the option for the synchronization link cable either the FO cable link or copper cable link. SD external memory card slot. The SD external memory card slot is for the optional external SD memory card. This card can be used for application and data storage. It is a 4 GB; Class A card rated for industrial use and shall be manufactured from the same automation vendor. Programming The controller platform shall have the ability to change the configuration on the fly without stopping the process. The user shall be able to change the configuration online while the system is running normally without stopping the process such as: • Adding the new IO modules. • Deleting the IO modules. • Hot swap faulty IO modules without stopping the process. • Adding the new backplane. • Adding the new control block. • Deleting the unused control block. • Change the parameters of the function block. The controller shall comply with the Five IEC 61131-3 programming languages. The languages are: • Function Block Diagram • Ladder Logic Diagram • Instruction List • Statement List • Sequential Function Chart These five languages shall use the standard set of instructions compliant with IEC standard 61131-3 to create the control applications which can be transferred from one platform to another (for example to the bigger/powerful CPU model reference). The software for configuring the controller shall have a standard function and function block libraries manager contains the elements provided. Functions and function blocks are organized into libraries, which themselves consist of families. However, the “Base Lib” library contains a set of functions and function blocks, for the majority of which compatibility is independent of the platforms. In particular, it contains the blocks compliant with IEC 61131-3. The “Base Lib” library is structured into families: • Timers and counters • Process control on integers • Table management • Comparison • Date and time management • Logic processing • Mathematical processing • Statistical processing • Character string processing • Type-to-type data conversion • PID FDT/ DTM Technology The software facilitates the integration of field bus architectures into engineering control systems using FDT/DTM technology: • FDT (Field Device Tool) is the container which supports the device DTMs. • DTM (Device Type Manager) is the configuration tool for devices with integrated graphic interfaces. It contains the properties specific to each device. The use of the Master DTM allows the software to perform the following actions: • Manage the I/O scan • Create the application variables based on the description of the process objects available from the connected DTM devices • Manage synchronization with the controller configuration • Create a generic DTM from the description files (GSD or EDS) The DTM configuration is stored in the controller memory so that the application can be downloaded in its entirety. It is also saved in the controller project file (STU), the archive file (STA), and the full application exchange file (ZEF). A third-party DTM can be installed in the DTM hardware catalog. The DTM hardware catalog can be used to sort or filter the DTMs according to various criteria such as Device, Vendor, Groups or Protocols. Security The control system shall have the protection from cyber-attack. The access to the process control system shall be limited and protected against the unauthorized access and other cyber threats. The protection shall be a combination of cryptographic and protocol security mechanism. The system must be able to secure communication between controller and system server providing authentication and integrity of data. The CPU module shall have the option to enable or disable the Ethernet services to increase protection from cyber-attack and from unauthorized access to the controller. The Ethernet services are: • FPP • TFTP • HTTP • Access Control • DHCP/ BOOTP • SNMP • Ethernet IP • Port 502 The goal of secured communication is to protect the communication channels that allow remote access to the CPU control system application logic and firmware. Any modification of the operating mode of the CPU module (Run / Stop / Program modifications) must be authenticated and logged. The PLC CPU module shall be certified with the Achilles Level 2 Certification. The Achilles Level 2 test employs more tests, Denial of Service tests at higher link rates, and more pass/fail requirements. IO Architecture Topology The communication from the CPU module to the IO rack shall be based on open and standard Ethernet ring technology with 100 Mbps transmission speed. The CPU module shall be able to handle the communication with the IO rack without additional dedicated communication modules. The Ethernet ring topology shall support the RSTP communication protocol to ensure high availability of the system with recovery time less than 50 ms. IO Modules Each input/output signal counting shall be provided with at least 20 percent spare inputs and outputs of each type or one spare card of individual type whichever is higher. Spare I/O shall be installed, wired, and interfaced properly to the terminal strip. The discrete and analog input/output modules of the controller IO family shall be in standard format modules occupying one single position at the backplane, fitted with either: • one 20-pin terminal block or • one or two 40-pin connectors at the front of the module, to allow removal of modules without disconnecting individual wires, and has a galvanic isolation. A wide range of discrete inputs/outputs module shall be available to make it possible to meet the following requirements: • functional: direct or alternating inputs/outputs, with positive or negative logic • Modularity: 8, 16, 32, or 64 channels per module. The IO communication adapters exchange data via an I/O scanner service, which resides in the CPU module on the main local rack of your PAC system: • The input data from the I/O drop is collected and published to the I/O scanner. • The output modules are updated with the data received from the I/O scanner. • The protocol used for exchange is Ether Net/IP. • The exchanges are deterministic, which means that the remote I/O logic is scanned regularly in a scheduled and predictable manner. Digital Inputs The discrete input modules shall be equipped with a display block featuring LEDs that displays the module channels status the overall module status. The LED display shows: • Run Status, to show the input module is operating normally • Error Status, to show the internal error inside the module • IO, to show the external event: overload, short-circuit, sensor error. All input modules contain a device for checking sensor voltage for all module channels. This device checks that sensor and module power supply voltages are of a sufficiently high level for correct operation of the module’s input channels. When sensor voltage is less than or equal to the defined threshold, the status is shown by the I/O LED lighting up on front panel of the module. • Channel Status, to show the logic true or false at the input channel (lit when true logic has). The discrete input modules shall be 24 VDC sink, in 32 input channels modularity. The required technical detail for the digital inputs module: Type 24 VDC positive logic Number of Channel 32 Nominal Input Values Voltage 24 VDC Current 2.5 mA Threshold input At 1 Voltage >= 11 V values Current >2 mA At 0 Voltage 5V Current <1.5 mA Sensor supply 19-30 V Input Impedance At nominal U 9.6 kOhm Response time Typical 4 ms Maximum 7 ms Reverse polarity Protected IEC 1131-2 Compliance Type 3 Dielectric Strength Primary/Secondary 1500 V actual 50/60 Hz for 1 min Between channel groups 500 VDC Resistance of insulation >10 Mohm Type of input Current sink Paralleling of input No Sensor voltage: monitoring Ok >18 VDC threshold Error <14 VDC Sensor voltage monitoring On appearance 1 ms<T<3ms response time On Disappearance 8 ms<T<30 ms Hot Swap Yes Standards CSA C22.2 No 142 IEC 1131-2 IEC 664 NF C 63-850 UL 508 UL 746C Digital Outputs The discrete output modules shall be equipped with a display block featuring LEDs that displays the module channels status the overall module status. The LED display shall at least shows: • Run Status, to show the input module is operating normally • Error Status, to show the internal error inside the module • IO, to show the external event: overload, short-circuit, sensor error. • Channel Status, to show the logic true or false at the input channel (lit when true logic has). Every module shall have a protection device which allows the following to be detected when an output is active: • An overload or short circuit. Events such as these cause the output to be deactivated (tripped) and the event to be indicated on the display on the front panel of the module (the LED corresponding to the channel flashes, the I/O LED comes on). • Reversal of polarity. An event such as this causes the power supply to short circuit without damaging the module. In order to obtain optimal protection, a quick-blow fuse must be installed on the power supply and upstream from the pre-actuators. • Inductive overvoltage. Each output is individually protected against inductive overvoltage and has a fast electro-magnet demagnetization circuit using a zener diode which allows the mechanical cycle of certain fast machines to be reduced. The discrete output modules shall be 24 VDC source, in 32 input channels modularity. The required technical detail for the digital output module: Type 24 VDC positive logic Number of Channel 32 Nominal Input Values Voltage 24 VDC Current 0.1 A Threshold input values Voltage 19…30 Current /Channel 0.125A Current / Module 3.2 A Leakage current At 0 100 microA for U=30V Voltage drop At 1 <1.5 V for I=0.1A Load Impedance 220 ohm Response Time 1.2ms Compability with IEC1131-2 DC Yes type 3 Built in protection Against overvoltage Yes by Transistor diode Against inversion Yes by inverted diode Against Yes by current limiter short- and electric circuit- circuits and breaker overloads 0.125A<Id<0.185A Pre-actuator voltage: monitoring Ok >18 V threshold Error <14 V Pre-actuator voltage: monitoring On appearance 1 ms<T<3ms response time On disappearance 8 ms<T<30ms Hot swap Yes Standards CSA C22.2 No 142 IEC 1131-2 IEC 664 NF C 63-850 UL 508 UL 746C Analog Inputs The analog input module shall be 4-20mA, 8 channel isolated analog channels. The module uses a 4- 20 mA analog signal to perform monitoring and measurement functions. The required technical detail for the analog input module: Number of channels 8 Type of Inputs High density inputs Nominal range full scale 4-20 mA Maximum conversion range 0.16 … 29.92 mA Measurement accuracy for module: ▪ At 25oC 0.15% of full scale ▪ At 0…600 celcius 0.3% of full scale Temperature drift 50 ppm/0C Display resolution 15 bit plus sign bit Isolation ▪ Between channels 50 VDC ▪ Between channels and bus 1400 VDC ▪ Between channels and ground 1400 VDC Vibration 10 mm/3g/x10 (per IEC60068-2-6) Shock 30g/11 ms/x3 (per IEC60068-2-27) Field device support 2 wire / 4 wire Response Time 9ms for 8 Channels Input impedance 250 Ohm Hot Swap Yes Analog Outputs The analog output module shall have at least 4/8 analog channels. The module uses a 4-20 mA analog signal to perform continuous process control functions. The required technical detail for the analog output module: Number of channels 4 Type of Inputs Current configured by software Nominal range full scale 4-20 mA Maximum conversion range 0…20 mA Measurement accuracy for module: ▪ At 25o 0.1% of full scale ▪ At 0…60 celcius <=0.25% of full scale Temperature drift 45 ppm/0C Display resolution 15 bit plus sign bit Isolation ▪ Between channels 50 VDC ▪ Between channels and bus 1400 VDC ▪ Between channels and ground 1400 VDC Vibration 10 mm/3g/x10 (per IEC60068-2-6) Shock 30g/11 ms/x3 (per IEC60068-2-27) Field device support 2 wire Conversion Time <=4ms Input impedance 350 Ohm Hot Swap Yes PLC Hardware and Certification The hardware controllers, IO modules, communication modules and backplane used for the water treatment process control system shall comply with the principal national and international standards concerning electronic equipment for industrial automation systems: • Requirements specific to programmable controllers: functional characteristics, immunity, resistance, safety, etc.: IEC/EN 61131-2 and IEC/EN 61010-2-201, UL and CSA standards for industry (UL 61010-2-201, CSA C22.2 No. 61010-2- 201) • Requirements specific to power utility automation systems: IEC/EN 61850-3 • Merchant navy requirements of the major international organizations: unified in IACS (International Association of Classification Societies) • Compliance with European Directives for e marking: • Low Voltage: 2006/95/EC and 2014/35/EU from April 2016 • Electromagnetic Compatibility: 2004/108/EC and 2014/30/EU from April 2016 All components of the controllers shall be capable of continuous operation at least at ambient temperatures of 0-60°C and humidity of 5-95%, altitude between 0 – 2,000 meters and has option for the conformal coating type which are able to withstand harsh and corrosive industrial environment as a standard product, without special requirement for heating, cooling or electrical filtering. Service conditions: Parameter Measurement Standard Environment Operation oC 0 … +60 Temperature Storage oC 0 … +85 Temperature Cyclical Humidity % 5 … +95 up to 55oC Continues Humidity % 5 … +93 up to 55oC Altitude Operation m 0…2,000 (full specification: temperature and isolation). 2,000... 5,000 (temperature derating: 1 °C/400 m, isolation lost: 150 V c/1,000 m) The available AC or DC power supply module shall be capable of accepting a +/- 20% input voltage variation from nominal voltage without shutting down. The hardware components must have product certification for: • UL • CSA • RCM • EAC • Hazardous location Clas 1 Div 2(CSA Hazardous Location according to ANSI/ISA 12.12.01, CSA 22.2 No. 213, and FM 3611.) • IEC, IECEx, Ex ( zone 2/22)one The hardware components must also conform to the main certifications relating to marine classification: • BV (Bureau Veritas/France) • DNV (Det Norske Veritas/Norway) • GL (Germanischer Lloyd/Germany) • LR (Lloyd’s Register/United Kingdom) • RINA (Registro Italiano Navale/Italy) • ABS (American Bureau of Shipping / USA) • RMRoS (Russian Maritime Register of Shipping / Russia) All major components in plant control system items including (central processors modules, I/O modules, servers, network components, and any major panel accessories shall have CoO (Certificate of Origin) to maintain high quality of the product. Technical Specifications – Remote Terminal Unit (RTU) for Intake, Clarifloculator, IPS, MBR and ESR (OHT) The Bidder shall have complied following Technical Specifications for RTU, RTU Panel and GPRS Router. Remote Terminal Unit The RTU shall be an intelligent, modular unit, capable of both data acquisition and local data processing. It shall monitor and control local equipment in a standalone mode as well as being an intelligent node in a distributed system. It shall be based on multiprocessor architecture, in which a co-processor is used for handling on-board input/output channels. To facilitate initial installation, maintenance and future expansion, all external input/output modules shall connect to the basic RTU using a high-speed bus. The RTU shall be configured with a modern Windows application and programmed with open standard IEC 61131-3 programming languages. Programs shall be developed and downloaded either directly to the RTU using a standard RS-232 interface cable, USB, Ethernet, or remotely through the communication network media such as phone lines, dedicated lines, mobile IP systems or wireless radios. The RTU shall be supplied with the number and type of input/output modules and communication ports as indicated elsewhere in the specifications. Expansion shall be by plugging in additional input/output modules to the I/O bus. Central Processing Unit (CPU) The central processing unit shall consist of a high speed 32-bit microprocessor with 32-bit internal and external bus. The design should incorporate a separate co-processor for controlling input/output channels. The CPU shall be equipped with at least 256 MB RAM for application programs, system parameters and configuration and at least 256 MB FLASH Memory for firmware, application programs and file system. The CPU shall include a real-time clock/calendar, accurate to within one minute per month, with lithium battery backup. The battery will maintain the memory and clock/calendar for two years of power off time. The RTU shall provide an adjustable period for updating time from SCADA protocols in order to achieve accurate clock time. The CPU shall include an internal clock with at least 10mS resolution and be capable of applying timestamps at this resolution to internal and externally obtained data. Diagnostic LEDs shall be included for the following: a. RTU Status b. Wide area communication link activity such as transmit, receive c. Local peripheral communication link activity d. I/O point indication for all DI & DO points (as a minimum) The RTU shall include a built-in power supply with wide range input, at least 12VDC - 30VDC. The power supply shall be capable of providing 24VDC output to power field transmitters. Mixed process input/output The RTU shall be available in several basic configurations. As a minimum, the following are required in devices with minimum footprint. Further I/O shall be available through I/O module expansion. • 4 digital inputs, 4 analog inputs, 2 relay outputs, 4 counter inputs (shared with DI) Digital inputs shall be provided with 11 – 24 VDC range and shall tolerate 150% over-voltage. Digital inputs shall be configurable for reporting of time-stamped events (including unsolicited reporting of state changes), and alarm time dead bands. Digital input changes on the RTU’s local I/O shall be time-stamped to at least 200mS accuracy of actual input change, with an internal resolution of 10mS between detectable events. State change and timestamp shall be reported through DNP3 Level 4 SCADA protocols. The RTU shall include at least three high speed counters (up to 5 Khz) rated at 12/24 VDC. Counter input points shall include point quality such that an I/O module or other failure will indicate bad point quality if the point values cannot be updated. User logic shall also be able to derive bad point quality on a per-point basis. Point quality shall be indicated in the point database and through status flags on individual points in DNP3 Level 4 SCADA protocols. Digital outputs shared with digital inputs shall be dry contact (closure to ground) type inputs. Individual digital outputs shall use integrated relays with the following specifications: • Form A with common ground for each group of five outputs • Maximum operating voltage of at least 115 Vrms • Minimum 1000 Vrms contact to logic isolation Digital outputs shall be configurable for pulse output trains controlled by both protocol messages and user programming. Digital Output points shall include point quality such that I/O module or other failure will indicate bad point quality. User logic shall also be able to derive bad point quality on a per-point basis. Point quality shall be indicated in the point database and through status flags on individual points in DNP3 Level 4 and SCADA protocols. Analog inputs shall support HART pass through and be able to be selected as 0-5V, 1-5V, 0- 20mA and 4-20mA on any channel, 14 bit resolution, 0.2% accuracy over the operating temperature range, 0.1% accuracy at 77 F (25 C). Analog Inputs shall be single ended. Analog input changes on the RTU’s local I/O shall be time-stamped to at least 200mS resolution, with an internal resolution of 10mS between detectable events. Value and timestamp change shall be accessible by a user application and reported through DNP3 Level 4 SCADA protocols. Analog Input points shall include point quality such that I/O module or other failure will indicate bad point quality. User logic shall also be able to derive bad point quality on a per-point basis. Point quality shall be indicated in the point database and through status flags on individual points in DNP3 Level 4 SCADA protocols. Analog outputs shall support HART Pass through with minimum 12 bit resolution, 0-20mA and 4- 20mA selection on any channel, +/- 0.25% accuracy over the operating temperature range, 0.15% accuracy at 77 F (25 C). The RTU I/O shall be controlled by an independent co-processor. The state of digital and analog outputs shall be configurable to hold their last output value or go to the OFF condition when the application program is stopped. Communication The RTU shall possess a minimum of Seven built-in communication ports with the following characteristics: • Two Ethernet port 10BaseT / 100BaseT with individual Mac Address with DNP3 and Modbus TCP/IP configurable simultaneously. • Ethernet Service port and Remote IO ports shall not be considered for SCADA and Third- party communications. • One USB device port • Four Serial Port, software controlled to 115200 baud rate. At least two of these ports shall be software selectable for RS-232, and RS-485 2-wire operation. Serial ports shall support speeds from 300 to 115200 baud Mechanical Design The RTU shall be DIN rail mount. Front access to all controls, indicators, communication ports and power supply connection shall be provided. RS-232 and Ethernet communication ports shall use standard RJ style connectors to allow easy access using standard cables. All boards shall be coated with conformal coating, for protection against humidity and corrosion. Where sockets are used, they shall be machined type and be gold plated. Bifurcated or leaf contacts will not be accepted. All system components shall be constructed of corrosion resistant zinc plated steel with removable metal covers. Environment The RTU shall operate over an ambient temperature range of -40 C to 70 C (-40 F to 158 F) with a relative humidity 5% to 95%, non-condensing. The RTU shall operate from nominal power supplies 12-30 VDC, but shall tolerate a wider range than this. 115/240 VAC operation shall be provided through the use of an optional power supply. Certifications and Standards a) The RTU shall be certified with CE Mark b) Hazardous locations Class I, Division 2, groups A, B, C, and D T4 and Class I, Zone 2, IIC according to CSA C22.2 No. 213-17 and ANSI/ISA 12.12.01 c) All inputs and outputs (except the serial communication ports) shall survive ANSI/IEEE C37.90 surge withstand capability (SWC) tests without damage. d) RTU serial ports shall be static protected to +/- 15kV as conforming to IEC 801-2 and 2.5kV surge withstand capability as per ANSI/IEEE C37.90.1-1989. e) The RTU shall be certified to meet or exceed the following standards: RF emission compatibility: FCC title 13 part 15, Subpart B, Class A, CISPR22 Class A Electrical safety classification: c(CSA)us, CAN/CSA-C22.2 No. 61010-1 Hazardous area classification: CSA Class 1, Division 2, Group A, B,C,D Discharge Immunity: EN61000-4-2 Radiated immunity: EN61000-4-3 Fast transient immunity: EN61000-4-4 Surge immunity: EN61000-4-5 Communication Protocols The RTU shall support open standard protocols & following industry standard protocols: • DNP3 Level 4-Level 4 conformant Master and Slave serial and DNP3 Level 4 over IP, • DNP3 Level 4 Slave is required to have the ability to send DNP3 Level 4 Master Read and Control requests to a peer Slave RTU • Modbus RTU Master, Modbus RTU Slave • Open Modbus/TCP Client, Open Modbus/TCP Server Protocol Capabilities Allow up to 65500 stations to be addressed in one system. • Ability to transfer complete configurations and IEC61131-3 application programs and data over the communication network to the RTU using DNP3 Level 4 protocols. The RTU shall support these facilities via RS232, RS485, TCP/IP PPP serial links, TCP/IP Ethernet, PSTN, radio, cellular IP, etc. • Support for multiple master’s capability for all Slave protocols • Proprietary protocols shall not be used for remote communication with the device. Flexible Communications The RTU shall be able to intelligently route DNP3 Level 4 messages across all its communication ports and interfaces. This shall include the ability to filter messages based on source port, source and destination addressing, and include connection information for the destination device such as communications port, PSTN telephone number, IP address, UDP port number, etc. Data concentrator capability Data concentration shall include as a minimum: • DNP3 Level 4 serial protocol as a master, DNP3 Level 4 over IP (TCP and UDP) as a master • Ability to put remote device communications in service and out of service on an individual device basis • Accept Unsolicited message reports from remote devices • Full support for integrating point quality and event timestamps from remote device in to the RTU’s database without loss of information • Ability to select data concentrator to stop collecting data when event buffers are full • Communication status for each remote device available in the RTU’s point database • Communication statistics for polling and unsolicited messages available in the RTU’s point database • Provision for user program or protocol commands to the RTU to force an event poll, integrity poll, or remote device restart. Time synchronization When operating as a slave the RTU shall be capable of updating its time from the following time sources: • DNP3 Level 4 protocol serial time sync method over IP communications (TCP and UDP) • NTP over IP communications Multitasking The software shall be based on a multi-tasking executive system optimized for real- time environment. This shall include: • RTU Hardware watchdog management • Individual software task watchdog management Firmware Upgrades The operating system firmware shall be capable of being upgraded locally and remotely, utilizing compression techniques to minimize the communications transaction size for loading of firmware patches or a new firmware image. The firmware upgrade shall not commence until complete reception of the firmware image. RTU operation shall not be interrupted during the communications transfer of the firmware image. TCP/IP Communications The operating system shall include TCP/IP services that encompass, but are not limited, to the following: • TCP socket interface for open protocols (Open Modbus/TCP) • Both TCP and UDP socket interfaces for DNP3 Level 4 open protocol • TCP socket interface for IEC61131-3 programming interface • ICMP (ping) management as a client and server • Telnet to RTU diagnostics stream • FTP file transfer to RTU file system • IP network table supporting Gateway, Host, Sub-network entries The following IP services shall be disabled by default as a security measure: Telnet, FTP, NTP, BOOTP Diagnostics Detailed diagnostics shall be available from the RTU including the following features: • Command line interface for interacting with the RTU's file system and diagnostics. • Command line via serial port connection using a generic terminal application. (The serial port shall also be selectable for purposes other than dedicated command line) • Command line from configuration application via USB, Telnet • Command line via DNP3 Level 4 Protocol Virtual Terminal User Programming Software: The RTU shall support all five IEC 61131-3 programming languages: a) Sequential Function Chart (SFC) b) Functional Block Diagram (FBD) c) Ladder Diagram (LD) d) Structured Text (ST) The RTU configuration and programming software shall be accessible from a single user interface. The software shall allow the user to develop and then download the application and system configuration locally via USB, serial port or Ethernet interface, and over the communication network via TCP/IP, DNP3 Level 4 protocols. Event Capability The RTU shall natively support event facilities without the need for user programming. Open protocol event capabilities for DNP3 Level 4 shall be fully integrated with the RTU’s event facilities. The number of events stored by the RTU shall be configurable, with a maximum up to at least 100,000 events. The RTU shall provide the following capabilities: • Generate events from physical or derived data objects • Accept, process and chronologically sort events from external devices • Merge external events using the original timestamp information provided by an external device • Where a timestamp is not supplied externally, the RTU shall add a timestamp to all event data • Report Binary, Counter, Integer analog and Floating-point analog events as a minimum • Report events for analog points on rate of rise exceeded, rate of fall exceeded and no change after a period. This functionality shall be provided natively without the need for user programming. • Event configuration for each data object shall include an event priority • Individual event configurations (e.g. each alarm limit) shall provide a selection for enabling an unsolicited communication transaction when the event is generated Data Logging functionality The RTU is required to have the following data logging functionality in addition to its event capabilities. The RTU shall support both event and data log operation simultaneously, including both event generation and logging on the same RTU data objects. Logging shall be selectable on digital input, digital output, analog input and analog output data objects. Analog logging shall be by 32-bit floating point engineering values. Logging shall be configurable to include current value and summary statistics at a defined interval, including average, maximum and minimum logging trends. Logging frequency shall be selectable by the user for each logging trend and vary from 1 second to 1 year. All data shall be able to be retrieved and made available as a.csv file for use in Excel, Access, or HMI software. Data uploaded to a PC shall be supported using direct serial connection, leased telephone lines, radio, dial-up modem, external memory media and via the SCADA communication link. Security RTU shall support next generation Cybersecurity features such as RTU security access control, individually addressable Ethernet Ports, IP White-listing, and are tested to meet cyber security communications robustness. The RTU shall provide communications security using recognized SCADA security open standards. Communication link security shall be provided for the DNP3 Level 4 open protocol as a minimum, supporting operation on serial and network links. This shall include DNP3 Level 4 Secure Authentication V2 as a minimum with an option for data encryption. Security standards shall be aligned to FIPS-120 standards and include AES-128 encryption and HMAC SHA-256 hash algorithms as a minimum. A secure administration application shall be provided for the Security Administrator to issue and track security keys, users and configuration computer nodes. The administrator application shall provide the capability of specifying security configuration for groups of RTUs, users (via username/password) and individual configuration. PLC system cabinet / Control Desk General Control Panel shall be CNC machine prefabricated out of CRCA sheet steel of thickness not less than 2 mm, modular in construction, properly reinforced, powder coated and having rigid frame structure. Internal mounting plate including the gland plate shall be 3 mm thick. The control panel shall have dimensions as per system requirement. However, the control panel height shall not exceed 2200 mm. The exterior corners and edges shall be rounded to give a smooth overall appearance with projections kept to a minimum. Lifting lugs shall be provided for installation purposes and shall be replaced with corrosion resistant bolts after installation. Control Panel shall be completely metal enclosed and shall be dust, moisture and vermin proof. Panel enclosures shall provide a degree of protection not less than IP 54 in accordance with IS: 13947 Part-I. Control Panel shall be freestanding type. There shall be sufficient reinforcement to provide level surfaces, resistance to vibrations and rigidity during transportation and installation. Metal sills in the form of metal channels properly drilled shall be furnished along with anchor bolts and necessary hardware for mounting the control panels. Cable entries to the panels shall be from the bottom Control panels shall be provided with louvers along with washable micron filters AIRIN – AIROUT fans will be provided. Mounting All equipment on front of panel shall be mounted flush or semi-flush. In case of semi- flush mounting, only flange or bezel shall be visible from the front. Equipment shall be mounted such that removal and replacement can be accomplished individually without interruption of service to adjacent equipment. Equipment mounted inside the panel shall be so located that terminals and adjacent devices are readily accessible without the use of special tools. Terminal markings shall be clearly visible. Earthing for Instruments The panel shall be equipped with an earth bus securely fixed along the inside base of panel. All metallic cases of instruments and other panel mounted equipment shall be connected to the instrument earth bus. Looping of earth connections which would result in loss of earth connection to other devices when the loop is broken shall not be permitted. However, looping of earth connections between equipment to create alternative paths to earth bus shall be provided. A separate instrument earth bus will be created which will be floating and all the cable shields will be terminated onto this bus. This bus will be connected to an electronic earth pit. Frame Earthing All metal parts other than those forming part of an electrical circuit shall be connected to a copper earth bar run along the inside bottom of the panel. The minimum section of the earth bar shall be 25 mm x 3 mm. A 15 mm diameter hole is to be provided at each end of the bar. Connection of the earth bar to the station earth shall be carried out by Contractor. Space Heater Strip type space heaters of adequate capacity shall be provided inside control panels to prevent moisture condensation on the wiring and panel mounted equipment when the panel is not in operation. The heaters shall operate on 230 V AC. Heaters inside the panels shall not be mounted close to the wiring or any panel mounted equipment. The operation of heaters shall be controlled by thermostats. Interior Lighting and Receptacles Each panel shall be provided with either a CFL lighting fixture rated for 11 watt, 230V, 1 phase, 50 Hz supply for the interior illumination of the panel during maintenance. The illumination lamp shall be operated by door switch or manual switch. Each panel section shall be provided with separate lighting. Each panel shall be provided with 230V, 1 phase, 50 Hz, combined 5 amps and 15 amps, 3 pin receptacle with a switch and neon. The receptacle with switch shall be mounted inside the panel at a convenient location. If the panel has front and rear doors then maintenance socket shall be provided at both locations. Voltage Level and Power Supply Units Generally, voltage levels for control schemes and power supply for instruments in the panels, shall be limited to 24 V DC. In case the instruments require power supply other than 24 V DC, Contractor shall provide necessary transformers, converters, inverters and other associated hardware required to generate the requisite power supply. The power supply distribution board for panel mounted and field mounted instruments shall be provided. Power supply to all the instruments mounted outside the control panel shall be provided from the power supply units in the control panel. The power supply to all the instruments shall be without interruption and shall be continued even in case of failure of 230 V A.C. power supply. UPS sizing should take this into consideration. Labels All the equipment mounted on the front facia of control panel as well as equipment mounted inside the panels shall be provided with individual labels with equipment designation engraved. The labels shall be mounted directly below the respective equipment. Also the panel shall be provided at the top with a label engraved with panel designation. Switches and Miniature Circuit Breakers (MCBs) Each control panel shall be provided with necessary arrangement for receiving, distributing, isolating and protecting of DC and AC supplies for various control, signaling, lighting and space heater circuits. The incoming and sub-circuits shall be separately provided with Miniature Circuit Breakers (MCBs). Potential circuits for relaying and metering also shall be protected by MCBs. All Important MCBs will be provided with an auxiliary contact to be used for providing MCB tripped alarm. Intra-panel (i.e. Panel Internal) Wiring Connections within a panel, between panel mounted devices and terminal blocks or between two panel mounted devices will be made by 660 volt grade, stranded copper conductor insulated with PVC and designed for a minimum conductor temperature of 90 degrees centigrade. The wires shall be shielded, where necessary. Panels shall be supplied completely wired internally, with a colour coding scheme decided mutually between the department and the Contractor, to equipment and terminal blocks and ready for external cable connections at the terminal blocks. Wires within the panel shall be continuous i.e. without splicing and shall comprise stranded copper conductors. Internal wiring or wiring between the two assemblies shall be commensurate with mechanical safety. Wire termination shall be made with solderless crimping type of tinned copper lugs which firmly grip the conductor and insulation. Insulated sleeves shall be provided at all the wire terminations. Engraved core identification plastic ferrules, marked to correspond with panel wiring diagram shall be fitted at both ends of each wire. Ferrules shall fit tightly on the wires and shall not fall off when the wire is disconnected from terminal blocks. The ferrule system shall adopt single tube printed arrangement so that all the characters remain on one line always & hence easily readable. Terminal Blocks Terminal blocks for power connection shall be 660V grade, 10 amps rated, one-piece moulded, complete with stud type terminals, washers, nuts and lock nuts and identification markings. Markings on the terminal strips shall correspond to wire numbers on the wiring diagrams. All control output terminals will be fused type and all other input signal terminals will be clip on shrouded type. Spare contacts and terminals of the panel mounted equipment and devices shall be wired to terminal blocks as required. There shall be a clearance of 250 mm between the first row of terminal blocks and the associated cable gland plate. Also the clearance between two rows of terminal blocks shall be 250 mm. Panel internal wiring shall not be looped directly from instrument to instrument. The same shall be looped through the panel terminal block only. If accidental short circuiting of certain wires is likely to result in malfunction of equipment, such as closing or tripping of a breaker or positive and negative wires, these wires shall not be terminated on adjacent terminal blocks. Cable Supports All external cables shall present a neat appearance and shall be suitably braced, placed in troughing clipped or laced to prevent effects of vibration. Terminal/Identification Every terminal and test plug shall be uniquely identified within the terminal cabinet by means of a terminal number. Appropriate labels shall be used to permit quick and unambiguous identification of each terminal and test plug. Painting of System Cabinet/ Control Desk All sheet steelwork shall be phosphated in accordance with the following procedure: • The pre treatment shall be hot process with running water for rinsing. • Oil, grease, dirt and swarf shall be thoroughly removed by emulsion cleaning. • Rust and scale shall be removed by trickling with clean water followed by final rinsing with dilute dichromate solution. • The control panel shall be powder coated. Thickness of coating of minimum 60 microns. QA test certificate shall be furnished for thickness, adhesion and hardening of powder coating. Technical Specification SCADA Architecture The SCADA architecture shall provide the following: • Client / Server architecture. • Symmetric main-standby & capacity for triple standby server functionality. • Additional servers for user load-sharing. • Fully automated data transfer between servers to provide complete server redundancy. This transfer shall include configuration, real-time data, historic data and event lists. Database updates shall be on an incremental basis. • A scalable, fully distributable architecture providing: • Unlimited number of server systems. • Unlimited number of display clients. • Where multiple servers are deployed, the system shall be capable of being configurable from a single client. • All redundancy shall be handled by the database, with the operational state of systems preserved through a server changeover. The system shall not rely on driver redundancy for data transfer when providing redundant server. The system shall present a uniform view of data including communication status after a server change- over. • Configurable compression of data communications between client/server and server/server to allow optimisation of communications performance over WAN networks. • Change reporting on Client/Server and Server/Server links rather than polled communication to permit operation on WAN networks. • Capable of operating Client/Server and Server/Server links over low to medium speed channels depending upon database size (e.g. 128K) • Support for DMZ (read-only) servers Operation is required on: 32- Bit Machines Desktop Hardware: • Windows 10 (Professional and Enterprise Editions) • Windows 8 / 8.1 (Professional and Enterprise editions) • Windows 7 (Professional and Ultimate editions) - Service Pack 1 64-Bit Machines Server Hardware: • Windows Server 2016 (Standard and Datacenter editions) • Windows Server 2012 Release 2 (Standard and Datacenter editions) • Windows Server 2012 (Standard and Datacenter editions) • Windows Server 2008 Release 2 (Standard and Enterprise editions) – Service Pack 1 Desktop Hardware: • Windows 10 (Professional and Enterprise Editions) • Windows 8 / 8.1 (Professional and Enterprise editions) • Windows 7 (Professional and Ultimate editions) - Service Pack 1 Operation shall be supported on both physical and virtual infrastructure, and when hosted on the latter it shall allow interfacing with shared storage and other peripherals. Database The SCADA database shall be of true relational database design and optimised for real-time SCADA operation. The database shall be object-oriented and organised in a hierarchical structure. It shall support user-created “Templates” that allows management of common configuration from a single point in the database. Instances of templates shall be used for repetitive, standard configuration. Templates of standard configuration shall support multiple object types including, but not limited to: • Point objects • PLC or RTU objects • Mimics • Trends • Maps • 3D Plots • Logic objects • Schedules • Link objects • Linked tables Templates shall support the ability for the value of object’s property within an instance to be calculated by the system using an expression. The database shall enable the user to perform automatic (scheduled) or manual database backup. While the backup is in progress, the database shall continue to operate; processing values, storing updates in memory and synchronizing updates to the standby. When the backup is complete, all updates shall be flushed to disk. The backup task shall copy the following files: • Database: Metadata, Structure, Configuration and Data • Historic Data • Event Journal Data • Configuration Change Data • Alarm Summary Data • Registry Settings Backup of historically stored records includes a configurable time range to allow the amount of historic backed up to be tuned to control both the backup size and execution to be kept within sensible limits on systems with large quantities of historic data Operator Interface • SCADA software shall provide the ability to support multiple local and remote display clients. • Display facilities shall be available via LAN, WAN and dial-up connection. • Integrated Web Server capability shall be available, providing all display and operational facilities of the Rich Client without the need for additional software to be installed. • Web Clients shall allow users to view Mimics, Trends & Plots, Database Objects, and • Reports as well as perform control functions using a standard web rowser. • Changes made to the SCADA server shall require no additional steps to be performed in order for those changes to be available to Rich Clients and Web Clients. • Full function display clients shall automatically detect & reconnect to a redundant server node when server change-over occurs. • Display clients shall support a minimum of 6 monitors (multi-monitor) • Web client shall provide support for Internet Explorer 9, 10 and 11, and allow access to view data, alarms, events, trends and query results from any HTML5 browser Mimics SCADA system Mimics shall support a wide range of graphical facilities. Scalable vector graphics are required in order to permit operation of the SCADA system with different resolution clients operating simultaneously. Fixed resolution bitmap graphics are not acceptable. Mimics shall be multi-layered, object oriented and permit mimics to be embedded in other mimics. Objects embedded and displayed on any mimic shall be viewable through both the full function client and web client displays. Trends The Trending System shall include facilities to display pre-configured and ad-hoc graph displays. The colors of variable traces shall be allocated by automatically, which may then be changed by the user. The color of X and Y axes shall also be configurable. It shall be possible to combine data from different parameters, from different time/days and different data sources, in order to perform calculations within the trending display (e.g. display the result of subtracting variable B from variable A). It shall be possible to apply a configurable multiplier to the variable. It shall be possible to select from a number of pre- configured algorithms including (but not limited to) Average, Max, Min, Time Average, Start, End, Sum, Count, Total, Variance, Standard Deviation, and Delta. It shall be possible to configure additional accumulating or moving algorithms for selection within the trending interface. It shall be possible to select from a number of pre-defined columns to display algorithm data for all configured traces, including Count, Sum, Total, Minimum, Maximum, Mean, Range, Delta, Standard Deviation, and Variance. The facility to select logarithmic scales and/or inverted scales for the Y-axis shall be provided. It shall be possible to superimpose more than 50 variables onto graphs showing the trace with its alarm limits. It shall be possible to enable/disable the display of any configured variable without the need for reconfiguration. It shall be possible to display from both historic and current data on the same display. The time-axis shall support continuous scrolling mode to display new data as it comes into the system. It shall be possible to export the data displayed within a graph, for example to CSV, MS Excel, MS Word. Location Support & Maps All database objects shall be able to store static or dynamic WGS84 coordinates which can include Latitude, Longitude, Height, Accuracy (XY and Z), and Date/Time of last location update. The system shall allow for native creation of geographical regions by either configuring a pre- defined circle or rectangle, or by specific definition of a polygon. User accounts shall be able to be linked to geographical regions for the purpose of automatic alarm notification. The system shall support filtering of alarms by configured region(s) Alarm Management The alarm system shall provide facilities where actions can be triggered by alarms. These facilities shall be provided as a built-in integrated part of the system and shall include, but not be limited to the following: • Configuration criteria for alarm actions • Escalate Alarm priority • Delivery of alarm to users via SMS • Delivery of alarm to users via E-mail • Trigger other actions including sequences Full function Clients & Web clients shall provide audible indication of alarm condition, with the ability to change alarm tone, color, and other attributes based on alarm priority. Support for Consequential Alarms (alarm suppression) shall be provided. The system shall provide, as a built-in feature and without the requirement for custom or external software, a built-in Alarm Summary to summarize key alarm information into a table with all related alarm information contained within a single record. Historical Data The SCADA system shall provide a built-in data historian with the following facilities as standard features. These shall be provided without the addition of external software modules: • Time-series relational database • ODBC / SQL interface to historical (trend) data • Historical data to be stored with time-stamp, point quality, alarm status • Historic storage is to be based on configurable criteria including time between samples, alarm state change • Compression capability Historical files supporting fixed interval sampling only will not be accepted. Where historic data can be retrieved through communication devices such as PLC/RTUs, the historic data sub-system shall natively provide the capability to backfill this data in to the historian. Loss of data or gaps in data as a result of communication or server failure shall not be accepted. The vendor must demonstrate its ability to ensure data integrity and history data recovery. System Security and Access The SCADA system shall provide a high level of inherent security. To this end the SCADA software shall provide security access down to data point level, and support individual Users, User Groups and a matrix of system capability and access to any level of the SCADA database. Full-function Rich & Web client interfaces shall require explicit administrative configuration to valid connection to the SCADA server. Client interfaces shall provide the ability to restrict access to sensitive system information based on user privilege. The system shall support a delayed lockout of user access after a consecutive number of failed logons. The delayed lockout restriction shall automatically expire after a configurable duration, re- allowing user access. Web interface facilities shall provide the capability to operate the Web interface using SSL and encrypted data. Changes in configuration to the SCADA system shall not require additional steps in order to provide modified information to the SCADA Web interface. Open Connectivity To provide easy access for customized reports and external data manipulation the SCADA software shall provide inherent OPC and ODBC database connectivity without the need for additional software options or modules. Integration with desktop Microsoft products is essential. The following Open interfaces shall be provided as integrated components of the SCADA system are required: • OPC Data Access (OPC-DA) to the SCADA server real-time and configuration database • ODBC to the SCADA server real-time / configuration database • OPC Historic Data Access (OPC-HDA) to historian • OPC Alarm & Event (OPC-AE) to event sub-system • OLE Automation interface to the SCADA server database •.NET support • ODBC / SQL to the SCADA historical database • ODBC / SQL to the SCADA event database • Support for specific database packages (e.g. Oracle) • SQL Export for creating csv files Reports An integrated reporting package shall be able to generate, print and export reports: • Triggered by SCADA events • On user demand • On timed schedules Report generation shall use latest technology in database access and be capable of combining datafrom multiple databases via ODBC/SQL. This shall include SCADA and non- SCADA databases Reports shall be able to be generated in a number of formats including: • HTML for viewing via Web interface • PDF format • CSV format • MS Office® suite format • Crystal Reports Generated reports shall be able to be: • Printed on a local or network printer • Stored on disk file, locally or remotely • e-mailed to assigned users Logic The SCADA system shall support logic sequences with full access to all SCADA system services at run time. Programming of sequences shall be to the IEC61131-3 international standard and support as a minimum the following languages: • Ladder Diagrams • Function Blocks • Structured Text • Sequential Function Charts The ability to store custom calculations and data via Data Grids/Data Tables/Data Sets shall be provided, including the ability to integrate elements of these Data Sets into individual Templates/Instances. Technical Specification Rack Server Rack based redundant server shall be required to for Centralized SCADA System. The bidder shall follow the minimum required specification for Rack Server as given below. Processor 2 x Intel Xeon Bronze 3106 ( 1.7 G, 16C/16T, 22 MB cache) RAM 4 x 16 GB DDR4, 16 Nos DiMM Slot available for Expansion Storage 4 x 1.8TB SAS 2.5” 10K RPM hot plug, (Max 8 nos 2.5” Bay) Raid 0,1,5 with H330 Raid Controller Display 21” LED Display DVD R/W DVD Read and Writer Power Supply Dual Redundant Hot swappable Power Supply OS Server Grade Operating system Additional Item Keyboard, Mouse, Ethernet Port – 2 Nos. 1GBPS Additional MS Office Home & Business 2016 Software Antivirus Server grade Antivirus Graphic Card PCI Graphics Card 4 GB DDR3 Technical Specification Work Station Work Station (2 Nos.) shall be required to operate Centralized SCADA System. The bidder shall follow the minimum required specification as given below. The bidder shall consider industrial grade control desk and chair (2 for each work station) for work station. Processor Intel® Xeon® Processor with 3.0GHz, 8M Cache RAM 16 GB DDR4 Storage 3*1TB 6G SATA 7.2K 3.5in NHP Hard drive,Intel RST SATA RAID Display 21” LED Display DVD R/W DVD Read and Writer Power Supply 300W Power Supply OS Server Grade Operating system Additional Item Keyboard, Mouse, Ethernet Port – 2 Nos. 1GBPS Additional MS Office Home & Business 2016 Software Antivirus Server grade Antivirus Graphic Card PCI Graphics Card 2 GB DDR3 Technical Specification 55” LED Display Bidder shall consider KVM switch and other required accessories for 55” LED display. The bidder shall follow the minimum required specification as given below. Panel Diagonal Size 55" Type 60Hz D-LED BLU Resolution 1920 x 1080 (16:9) Brightness (Typ.) 330 nits Contrast Ratio (Typ.) 5000:1 Viewing Angle (H / V) 178:178 Response Time (G-to-G) 6ms Orientation Portrait / Landscape Sound Built in Speaker (10W + 10W) Connectivity Input RGB Analog D-SUB, DVI-D Video HDMI1, HDMI2, CVBS Audio Stereo Mini Jack / RGB / DVI / HDMI / CVBS USB USB 2.0 x 1 Output Audio Stereo Mini Jack External Control RS232C (In / Out) thru Stereo Jack, RJ45 External Sensor IR of 405 Page 203 Power Type Internal Power Supply AC 100 - 240 V~ (+/- 10 %), 50/60 Hz Power Consumption Max [W / H] 176W Typical [W / H] 55W Sleep Mode < 0.5W Off Mode < 0.5W Dimensions Set 48.4" x 27.8" x 1.96" Package 53.1" x 31.9" x 5.8" Bezel Width (mm) 9.5 (Top / Side), 15.0 (Bottom) Weight Set 32.5 lbs Package 42.4 lbs Features VESA Mount 400 x 400mm Stand Type Foot Stand (Optional) Media Player Option Type Embedded (Lite SoC), Setback Box (Attachable) Special Hardware Super Clear Coating, Temperature Sensor, Pivot Display, Button Lock, Clock Battery (168 Hrs Clock Keeping), Built in Speaker (10W x 2) Software Auto Source Switching & Recovery, RS232C / RJ45 MDC, Plug and Play (DDC2B), Built In MagicInfo Lite, Firmware Update by Network, LFD New Home Screen Tuner Yes Internal Media Player MIPS 24K, 128KB L2 Cache, 650MHz processor, 512MB Main Memory Interface, Samsung Proprietary OS (VD Linux), 179 MB Storage Environmental Conditions Operating Temperature 0°C ~ 40°C Operating Humidity 10~80% Green Management Emission Standard EMC ENERGY STAR Compliant ENERGY STAR 7.0 (USA) RoHS Compliant Yes Packaging Recyclability Packing Materials Recyclable Service Standard Warranty 3 Years Onsite (Parts / Labor / Backlight) Technical Specification A4 printer The bidder shall follow the minimum required specification as given below. Functions Print Print speed (A4) Up to 16/16 ppm (black/color) Control panel 7 segment ICON LCD with 6 buttons (Up, Down, Colour Copy, Monochrome Copy, Setting, Cancel) and 6 indicator light (Ready, Error, CMYK toner low) Networking Fast Ethernet Print Print technology Laser Print speed1 Black (A4, normal): Up to 16 ppm; Colour (A4, normal): Up to 16 ppm First page out2 Black (A4, ready): As fast as 11.8 sec; Colour (A4, ready): As fast as 13.7 sec; Black (A4, sleep): As fast as 12.9 sec; Colour (A4, sleep): As fast as 14.2 sec Print resolution Black (best): Up to 600 x 600 dpi; Colour (best): Up to 600 x 600 dpi; Monthly duty cycle Up to 30,000 pages (A4); Recommended monthly page volume: 150 to 1,500 Fonts and typefaces 84 scalable TrueType fonts Print area Print margins: Top: 5 mm, Bottom: 5 mm, Left: 5 mm, Right: 5 mm; Maximum print area: 216 x 356 mm Duplex printing Manual (driver support provided) Processor speed 800 MHz Connectivity Standard Hi-Speed USB 2.0 port; Built-in Fast Ethernet 10/100 Base-TX network port Network capabilities Yes, via built-in 10/100 Base-TX Ethernet Memory Standard: 256 MB DDR, 128 MB Flash; Maximum: 256 MB DDR, 128 MB Flash Dimensions and Weight Printer Minimum: 420 x 380 x 292.6 mm; Maximum: 420 x dimensions (W x D x H) 435 x 295 mm Printer weight 15.7 kg Operating environment Temperature: 15 to 30ºC; Humidity: 30 to 70% RH Storage Temperature: -20 to 40ºC; Humidity: 0 to 95% RH Power Requirements: Input voltage: 220 to 240 VAC (+/- 10%), 50 Hz (+/- 3 Hz), 60 Hz (+/- 3 Hz) Consumption: 337 watts (Active Printing), 8.0 watts (Ready), 1.0 watts (Sleep), 0.1 watts (Manual-Off), 0.1 watts (Auto- Off/Manual-On), 1.0 watts (Auto- Off/Wake on LAN); Typical Electricity Consumption (TEC) 6: Energy Star: 0.493 kWh/Week; Blue Angel: 0.531 kWh/Week; Power supply type: Internal (Built-in) power supply Certifications CISPR 22:2008, CISPR 32:2012/EN 55032:2012 - Class B; EN 61000-3-2:2014; EN 61000-3-3:2013; EN 55024:2010, ENERGY STAR® qualified Blue Angel compliant: Yes, Blue Angel RAL-UZ 205 Technical Specification Ethernet Switch Bidder shall consider 2 nos. of industrial grade Ethernet Switches at CSS. The bidder shall follow the minimum required specification as given below. Physical Ports 10/100 Base-T(X) Ports in RJ45 16 Ports Auto MDI/MDIX Technology Ethernet Standards IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-TX and 100Base-FX IEEE 802.3z for 1000Base-X IEEE 802.3ab for 1000Base-TX IEEE 802.3x for Flow control IEEE 802.3ad for LACP (Link Aggregation Control Protocol ) IEEE 802.1D for STP (Spanning Tree Protocol) IEEE 802.1p for COS (Class of Service) IEEE 802.1Q for VLAN Tagging IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol) IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol) IEEE 802.1x for Authentication IEEE 802.1AB for LLDP (Link Layer Discovery Protocol) MAC Table 8192 MAC addresses Priority Queues 4 Processing Store-and-Forward Switch Properties Switching latency: 9 μs Switching bandwidth: 7.2Gbps Max. Number of Available VLANs: 4096 IGMP multicast groups: 1024 Port rate limiting: User Define Security Features Enable/disable ports, MAC based port security Port based network access control (802.1x) VLAN (802.1Q ) to segregate and secure network traffic Supports Q-in-Q VLAN for performance & security to expand the VLAN space Radius centralized password management SNMP V1/V2c/V3 encrypted authentication and access security Software Features STP/RSTP/MSTP (IEEE 802.1D/w/s) Redundant Ring (O-Ring) with recovery time less than 10ms over 250 units TOS/Diffserv supported Quality of Service (802.1p) for real-time traffic VLAN (802.1Q) with VLAN tagging and GVRP supported IGMP v2/v3 (IGMP snooping support) for multicast filtering Port configuration, status, statistics, monitoring, security SNTP for synchronizing of clocks over network Support PTP Client (Precision Time Protocol) clock synchronization DHCP Server / Client support Port Trunk support MVR (Multicast VLAN Registration) support Network Redundancy O-Ring Open-Ring O-RSTP STP RSTP MSTP Warning / Monitoring Relay output for fault event alarming System Syslog server / client to record and view events Include SMTP for event warning notification via email Event selection support RS-232 Serial Console Port RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1 LED Indicators Power Indicator Green: Power LED x 3 R.M. Indicator Green: Indicates that the system is operating in O- Ring master mode Fault Indicator Amber: Indicates unexpected event occurred 10/100Base-T(X) RJ45 Port Green for port Link/Act. Amber for Duplex/Collision Indicator 10/100/1000Base-T(X) RJ45 Green for port Link/Act. Amber for 100Mbps Port indicator Indicator Fault Contact Relay Relay output to carry capacity of 1A at 24VDC Power Redundant Input Power Dual DC inputs. 12~48VDC on 6-pin terminal block Power Consumption (Typ.) 12 Watts Overload Current Protection Present Reverse Polarity Protection Present on terminal block Physical Characteristics Enclosure IP-30 Dimensions (W x D x H) 96.4(W)x108.5(D)x154(H) mm (3.8 x 4.27 x 6.06 inch) Weight (g) 1220 g Environmental Storage Temperature -40 to 85°C (-40 to 185°F) Operating Temperature -40 to 70°C (-40 to 158°F) Operating Humidity 5% to 95% Non-condensing Regulatory Approvals EMI FCC Part 15, CISPR (EN55022) class A EMS EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4- 4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8,EN61000-4-11 Shock IEC60068-2-27 Free Fall IEC60068-2-32 Vibration IEC60068-2-6 Safety EN60950-1 Technical Specification GPRS Router Bidder shall consider industrial grade GPRS Router with minimum specifications as given below. Cellular Interface Standards: GSM/GPRS/EDGE/UMTS/HSPA+/FDD LTE FDD LTE: max. 150 / 50 Mbps (DL/UL) TDD LTE: max.112 / 10 Mbps (DL/UL) DC-HSPA+: 42 / 5.76 Mbps (DL/UL) HSPA+: max. 21.6 / 5.76 Mbps (DL/UL) EDGE: 236.8 kbps (DL/UL) GPRS: 85.6 kbps (DL/UL) SIM: 2 x (3V & 1.8V) Antenna Interface: SMA Female(1xMAIN and 1xAUX) Ethernet Interface Number of Ports: 2xLAN or 1 x LAN, 1xWAN (10 /100Mbps) Magnet Isolation Protection: 1.5KV System Reset button LED Indicators: RUN, PPP, USR, 3 x RSSI CPU & Memory CPU: 535MHz SDRAM: 64MB FLASH: 16MB Software Network protocols: PPP, TCP, UDP, DHCP, ICMP, NAT, DMZ, DDNS, VRRP, HTTP, HTTPs, DNS, ARP, SNTP, Telnet, etc VPN tunnel: IPSec/OpenVPN/GRE Firewall: SPI, anti-DoS, Filter, Access Control Management: Web, SMS, CLI Power Supply and Power Supply Interface: 3.5mm terminal block Consumption Input Voltage: 9 to 26 VDC Power Consumption: Idle: 100 mA @ 12 V Data Link: 500 mA (peak) @ 12 V Physical Characteristics Housing & Weight: Metal, 300g Dimension: (L x W x H) 127.5mm x 82.5mm x 29.5mm Installation: 35mm Din-Rail or wall mounting or desktop Operating Environment -20 to +65°C/ 5 to 95% RH Regulatory and Type Approval & Detective: CE, R&TTE, RoHS, WEEE Approvals EMI: EN 55022 (2006 / A1: 2007) Class B EMC: EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 4 EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3 EN 61000-4-6 (CS) Level 3, EN 61000- 4-8 Level 4 Technical Specification 5kVA UPS with 8 hour Battery Backup The bidder shall follow the minimum required specification as given below. Rating (in KVA) 5 KVA / 5 KW Input Nominal Voltage 230 V AC Nominal Frequency 50 Hz Input Power Factor 0.99 Input Voltage Range 160 ~ 275 VAC Frequency Range 45 to 55 Hz Output Invertor Design IGBT Based Technology Voltage 208 V / 220 Page 209 V of /405 230V / 240 VAC Voltage Regulation < 2% Waveform Pure Sine wave Total Harmonic Distortion < 1% for linear load &<5 % for non linear load Crest Factor 3:1 Overload capacity 105% ~ 125% for 10 min, 125% ~ 150% for 30 Sec. Environmental Operational Temperature 0 to 40 Deg. Relative Humidity 0 ~ 95% (Non Condensing) Physical Enclosure Protection IP 20 Cooling Forced Air Cooling Bypass Static Bypass Auto & Manual Maintenance Switch Facility required Transfer No Break Battery Type Sealed Maintenance Free Recharge Time 8-10 hrs VAH Required 36000 VAH Approx. Battery Backup 8 hours Battery Charger up to 12 Amp General Overall Efficiency on Full load 94% High Efficiency mode 98% Acoustic Noise (in dbA) < 65 dBA @ 1 Meter Alarms Audible Alarm required for Mains Failure, Low Battery, Inverter Trip, Over Temperature, Over Load Display Panel LCD Display with Measurements (Input / Output/BypassV & Hz, Battery Voltage & % Capacity) Battery Rack M.S. Angle with upper Cover Parallel Option up to 3 units Yes Communications Power Management Software Software CD Connection type USB / RS232 SNMP Interface Intelligent slot for SNMP / AS400/ Modbus 1. Open Channel Ultrasonic Flow meter: Unit Price: INR 80,000 + GST 18% a) Ultrasonic flow measuring system shall consist of a flow sensor, flow transmitter cum computing unit, prefabricated cable connecting the sensor and transmitter, and any other item required for completing the flow measurement system. b) The flow sensor shall be suitable for flange or bracket mounting as required. It shall have ambient temperature compensation and adjustable datum setting facilities. c) The flow transmitter cum computing unit shall be provided in an enclosure conforming to IP 66/67. It shall be programmable with an integral programming keyboard and shall provide an isolated 4-20 mAHART. Ultrasonic Flow transmitter Service: Water, Non-contact type Transmitter: Type Open channel Ultrasonic flowmeter Principle Pulse Time of flight Output 4-220 mA HART Number of sensor inputs 1 Polycarbonate for field housing / Die Material cast Aluminum Ingress Protection IP66 / IP 67 field housing +/- 0.2% of the maximum span of Accuracy the sensor Power supply 12-48 VDC Temperature from 0 deg C to 50 deg C Display (If required) LCD graphic display. Menu guided operation. Configuration Using Keypad on display Sensor Range 0 – 5m Max Temperature 80 deg C Max Pressure 4 bar abs Materials PVDF/PP Process connection G 1"/ 1" NPT or manufacturers standards Degree of protection IP67/IP68 Mounting Top Mounted 2. Full bore Electromagnetic Flow Meter: Technical Specifications for Full bore Electromagnetic Flow meter General 1 Application (Suitable Water / Sewage for) 2 Op Temperature 0 to 60 Deg C Max 3 Op Pressure As per requirement 4 Measurement Instantaneous water flow Rate, Totalized Flow Flow Sensor 5 Type In-Line Full Bore Electromagnetic flow meter. 6 Power supply type 230 V AC & 24 V DC Universal Power Supply 7 Sizes ( mm ) /Qty Refer Bill of Quantity for details 8 Sensor Type Pulsed DC 9 Process Connection Flanged type 10 Weather Protection IP68 Class Up to 6 m/s, vendor to provide the detailed 11 Full Scale Velocity sizing calculations based on the process details. 12 Electrodes Total Electrodes: 4 nos. Measuring electrodes – 2 Nos. Grounding electrode- 1 No. and Empty pipe detection electrode -1 No. MOC: For Raw/Drinking Water: SS316L For WasteWater/ Sewage: Alloy C22 Powder-coated die-cast aluminium Anti 13 Coil Housing corrosive grade 14 Flanges Carbon Steel PN 10 as per EN 1092-1 In- built Grounding Electrode SS316L is 15 Flow sensor Grounding must. Grounding rings are also acceptable 16 Flow Tube material SS304 For Raw / Drinking Water: Polyurethane or Hard Rubber For Waste Water/ 17 Flow Tube Liner Sewage: PTFE / PFA Flow Transmitter Unit Microprocessor based with facility to 18 Type configure the range 2 -Line display with 3 optical keys (touch 19 Type of Display control Operation.) Remote Wall Mounted with 20 cable glands, integrated fixing points for wall mounting, 20 Transmitter Type with sensor interface 21 Units For Display Flow Rate m3/Hr,Totalized Flow m3 22 Input From Flow Tube 23 Accuracy +/- 0.5 % of Measured Value 24 Operation Via local display (Touch Control Operation) 25 Output 4-20mA HART / RS485 26 Power supply 230 VAC &24 VDC Universal Power Supply. Required, following minimum diagnostic features shall be provided Empty pipe 27 Self-diagnostic feature detection, event logbook, system diagnostic features Transmitter Enclosure 28 material Non corrosive, polycarbonate. 29 Communication HART or RS485 30 Memory 100% secure data storage 31 Weather Protection IP 67 (NEMA 4X) for flow transmitter Class Duly Accredited According to ISO/IEC 33 Flow calibration rig 17025 facilities in India 3. Radar Type Microwave Level transmitter: Radar Level transmitter Service: Raw Water (Non-Contact Type) Transmitter Type Radar Type Level Transmitter Principle Time of flight Output 4-20 mAHART Dual Compartment Housing of Die Cast Housing Aluminum Ingress Protection IP 66/67 Accuracy +/- 3 mm Display 4 line LCD display. Menu guided peration. Configuration Using Keypad on display Sensor Range Liquids 0 to 30m Temperature range 0°C... +50°C Max Pressure 3 bar abs Materials Sensor: PVDF Seal: VITON/EPDM Threaded or universal flange dependent on Process connection model selection Degree of protection IP68 4. Ultrasonic Level transmitter: Ultrasonic Level transmitter Transmitter Type Ultrasonic Principle Time of flight Output 4-20 mAHART Housing Die Cast Aluminum Housing Ingress Protection IP66/67 ±0.2 % of the maximum span of the Accuracy sensor Area Classification Non-Hazardous Temperature range 0°C... +50°C Display 4 line LCD display. Menu guided operation. Configuration Using Keypad on display Sensor Range Liquids 0-5m, 0-8m, 0-10m As per requirement. Temperature range 0°C... +50°C Materials Sensor: PVDF/PP Seal: EPDM Threaded or universal flange dependent Process connection on model selection Degree of protection IP68 5. Pressure Transmitters: Sr. Specifications Pressure Range 0 to 10 /20/50/ 100 Kg/cm2 g No 1 Process 0 to +50 deg.C. Temperature range 2 Output Signal 4-20 mAHART 8 Supply voltage 24 V DC 11 Reference accuracy ± 0.1% of the set Span 13 Housing Die Cast Alu. Housing 14 Diaphragm Material SS316L 15 Display Operation 3 Key Push button for configuration COMMUNICATOR.A 4-line liquid crystal display (LCD) is used for display and operation 16 Long Term Stability ± 0.25% URL/year for 1 year, 5 year 6. Turbidity Measurement: Turbidity Measurement Transmitter Universal Transmitter for Turbidity Type / pH/Chlorine/DO Principle Light scattered at a 90° Output 4-20 mA HART Supply voltage 230 V AC Material Field Housing: ABS PC Non-corrosive type Display LC display with backlit. Multiline display for easy operation and understanding of errors. Protection class of field housing IP 66/67 Ambient temperature 0... +60 °C Self-Diagnostic feature Required Sensor Measurement range 0 – 4000 NTU Material Sensor: Stainless steel 1.4404 window: sapphire O-Ring: EPDM Max Process temperature 50°C Max Process pressure 10bar Connection Fixed cable connection Ingres protection IP68 Additional Certifications Calibration certification Resolution 0.001 NTU, 0.01 ppm, 0.1 g/l, 0.1% Measurement error <2% of meas. value (min. 0.02 NTU) Flow Through Assembly OEM 7. pH Measurement: pH Measurement Transmitter Universal Transmitter for Turbidity/ pH/ Type Chlorine/ DO Output 4-20 mA HART Supply 230 V AC Material Field Housing: ABS Polycarbonate non-corrosive Display LC display with backlit. Multiline display for easy operation and understanding of errors. Protection class of field IP 66/67 housing Ambient temperature 0... +60 °C Diagnostic feature Required, 3 point calibration Sensor: Measurement range 0 - 12 pH Material Glass Max Process temperature 110°C Max Process pressure 4bar temperature sensor Yes, Pt100 Connection Inductive digital connection with Transmitter Ingres protection IP68 Resolution 0.01pH, Temp 0.1°C Measurement Error ± 0.5% of Measuring range 8. Chlorine Measurement: Chlorine Measurement Transmitter Universal Transmitter for Turbidity/ pH/ Type Chlorine/ DO Principle Amperometric measurement of free chlorine with pH Compensation Output 4-20 mAHART Supply voltage 230 V AC Material Field Housing: Field Housing: ABS Polycarbonate non-corrosive Display LC display with backlit. Multiline display for easy operation and understanding of errors. Protection class of field IP 66/67 housing Ambient temperature 0... +60 °C Sensor Measurement range 0,01 - 5ppm free chlorine Material Sensor shaft: PVC Membrane: PTFE Membrane cap:PBT (GF30); PVDF Process temperature 2°C - 45°C Max Process pressure 1 bar temperature sensor NTC / Pt100 Connection Inductive digital connection with Transmitter/Analog cable connection Ingres protection IP68 Resolution 0.01mg/l Measurement Error ± 0.5% of Measuring range Flow through Assembly OEM SUPERVISORY CONTROL AND DATA ACQUISITION (SCADA) Sr Item Description Qty Unit Rates No. Main PLC Panel at Master Control Center with GPRS Router for components up to 50 Nos ( Including Intake well, WTP, IPS, MBR etc) Supply, Installation, testing and commissioning of fully wired PLC panel along with 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks and all other required 1 accessories as per specifications. The PLC shall be 01 No ₹ 13,18,920.00 32bit, Dual Core, controller having minimum 80DI/64DO/18AI modular IO’s along with minimum 1 no. of RS485 Serial port to communicate with Modbus devices, 1 No. of Ethernet port for SCADA at Master Control Center. ( Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc...) Main PLC Panel at Master Control Center with GPRS Router for components More than 50 Nos( Including Intake well, WTP, IPS, MBR etc) Supply, Installation, testing and commissioning of fully wired PLC panel along with 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks and all other required 2 accessories as per specifications. The PLC shall be 01 No ₹ 36,59,600.00 32bit, Dual Core, controller having minimum 256DI/128DO/80AI modular IO’s along with minimum 1 no. of RS485 Serial port to communicate with Modbus devices, 1 No. of Ethernet port for SCADA at Mater Control Station. ( Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc...) The modular Remote I/Os to control Panel ( Console Panel) 3 Filter bed operation having minimum 32DI/16DO/8AI 1 No ₹ 4,77,600.00 IO’s shall be required for each twin type filter bed with 7” Touch Screen HMI for local operation SCADA System along with Development Software 01 4 at Master Control Control Center (for components ₹ 44,43,480.00 Set up to 50 Nos) Sr Item Description Qty Unit Rates No. Supply, Installation, Testing and Commissioning of Supervisory Control and Data Acquisition (SCADA) system having capability to receive data on suitable protocol to support data backfilling (without third party software) facility, along with Historian and Data Analytics Tool, Remote access capability though concurrent client’s development licences and SCADA server and operator licenses shall be required SCADA Software along with Development Software at Master Control Control Center (for components above 50 to 200 Nos) Supply, Installation, Testing and Commissioning of Supervisory Control and Data Acquisition (SCADA) 01 5 system having capability to receive data on suitable ₹ 81,51,120.00 Set protocol to support data backfilling (without third party software) facility, along with Historian and Data Analytics Tool, Remote access capability though concurrent client’s development licences and SCADA server and operator licenses shall be required Remote Terminal Unit with RF Trans- Receiver Supply, Installation, testing and commissioning of fully wired RTU panel along with RF Trans-Receiver module having 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks, and all other required accessories as per specifications. The RTU shall be 32bit, Dual Core, conformal coated controller having minimum 4DI/4DO/4AI/2AO integrated IO’s along with minimum 2 nos. of RS485 Serial port to communicate with Modbus devices, 2 1 6 Nos. of Ethernet port for RF Trans-Receiver Module to Nos. ₹ 1,90,920.00 communicate with SCADA at Master Control Center on DNP3 Protocol with data backfilling facilities. Having capability of storing 1Lakh event and RTU should be integrated with suitable communication platform. RTU should be cyber secured and will be compliant with SAV2 secure authentication ( Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc.) with. IP65 Enclosure Application - Rotating Equipment like Clarifier Unit ( WTP) 7 Remote Terminal Unit along with GPRS Router 01 No ₹ 2,78,160.00 Sr Item Description Qty Unit Rates No. Supply, Installation, testing and commissioning of fully wired RTU panel along with GPRS Router having 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks, SIM Cards and all other required accessories. 7” Touch Screen Panel mounted HMI for local operation The RTU shall be 32bit, Dual Core, conformal coated controller having minimum 16DI/8DO/8AI integrated IO’s along with minimum 2 nos. of RS485 Serial port to communicate with Modbus devices, 2 Nos. of Ethernet port for GPRS Router and SCADA at Master Control Center on DNP3 Protocol with data backfilling facilities. Having capability of storing 1Lakh event and RTU should be integrated with suitable communication platform. GPRS Router Industrial grade with 50C operating temperature and 2 nos. of SIM card slots with 4G/5G connectivity. RTU should be cyber secured and will be compliant with SAV2 secure authentication. All works shall be carried out complete in all respects and as per tender document.( Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc...) with.IP65 Enclosure Application- Raw Water/Clear Water Pump House/IPS Control & Monitoring system for Single Village Scheme Supply, Installation, testing and commissioning of fully wired PLC panel having 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks, and all other required accessories. 10” Touch Screen Panel mounted HMI for operation The PLC shall be 32bit, Dual Core, conformal coated controller having minimum 16DI/8DO/8AI integrated IO’s along with minimum 2 8 nos. of RS485 Serial port to communicate with 01 No ₹ 2,55,675.00 Modbus devices, 2 Nos. of Ethernet port to GPRS Router and Central SCADA system on DNP3 protocol with data backfilling. Having capability of storing 1Lakh event and PLC should be integrated with suitable communication platform. All works shall be carried out complete in all respects and as per tender document. (Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc...) Application- Single Village Scheme 9 Remote Terminal Unit along with GPRS Router 01 No ₹ 1,87,320.00 Sr Item Description Qty Unit Rates No. Supply, Installation, testing and commissioning of fully wired RTU panel along with GPRS Router having 230VAC Input power supply, along with necessary protections and wiring of I/O signals with terminal blocks, Sim Cards and all other required accessories as per specifications. 4” Touch Screen Panel mounted HMI for local operation. The RTU shall be 32bit, Dual Core, conformal coated controller having minimum 4DI/4DO/4AI integrated IO’s along with minimum 2 nos. of RS485 Serial port to communicate with Modbus devices, 2 Nos. of Ethernet port for GPRS Router and SCADA at WTP on DNP3 Protocol with data backfilling facilities. Having capability of storing 1Lakh event and RTU should be integrated with suitable communication platform. GPRS Router Industrial grade with 50C operating temperature and 2 nos. of SIM card slots with 4G/5G connectivity. RTU should be cyber secured and will be compliant with SAV2 secure authentication.( Complete in all respect like Indication,Annunciator, Hooter,Control Transformer, SPD, Input termimal block with fuse, SMPS etc...) Application- Service Reservoir, MBR, BPT Workstation Grade PC’s Supply, Installation, Testing and Commissioning of 10 Intel Workstation Server grade PC with minimum 21" 01 No ₹ 1,76,500.00 LED Display, RAM:16GB, HDD>2TB with required licenses of OS, Office and Antivirus and other hardware and software Server Grade PC’s Supply, Installation, Testing and Commissioning of 11 Intel Xenon Server grade PC with minimum 21" LED 01 No ₹ 3,30,900.00 Display, RAM:64G/5GB, HDD>2TB with required licenses of OS, Office and Antivirus and other hardware and software UPS and Battery Supply, Installation, Testing and Commissioning of 12 redundant Online UPS along with accessories suitable for 8hr battery backup for the IT hardware at the command centre. Battery will be maintenance free SMF type and with suitable mounting racks. 13.1 1 KVA - (Redundant UPS with single Battery) 01 No ₹ 2,33,400.00 13.2 3 KVA ((Redundant UPS with single Battery) 01 No ₹ 5,00,000.00 13.3 5 KVA ((Redundant UPS with single Battery) 01 No ₹ 9,66,700.00 13.4 10 KVA (Redundant UPS with single Battery) 01 No ₹ 14,33,400.00 14 Control Desk 01 ₹ 66,700.00 Sr Item Description Qty Unit Rates No. Industrial Grade Control Desk MS power coated & Set having MDF top suitable for mounting of Workstation PC’s and Printer. A4 size commercial laserjet printer for continouse 16 01 No ₹ 46,700.00 duty 17 IO Extension Card Supply, Installation, testing and commissioning of IO 17.1 01 No ₹ 26,550.00 Extension in Exisiting PLC up to 4DI/4DO Supply, Installation, testing and commissioning of IO 17.2 01No ₹ 26,550.00 Extension in Exisiting PLC up to 12DI/8DO Supply, Installation, testing and commissioning of 18 Touch Screen Panel mounted HMI for Monitoring and control operation (for RTU Panels) 18.1 4" HMT SCREEN 01 No ₹ 14,750.00 18.2 7"HMI Screen 01 No ₹ 35,750.00 18.3 10" HMI Screen 01 No ₹ 73,375.00 Monthly Subscription Charges- Cloud Server Hosting Data 19 Cloud Based Server for software hosting and Data storage, Data Traffic & Maintenance Charges 19.1 No of OHT up to 50 Nos 1 Job ₹ 9,44,000.00 19.2 No. of OHT between 50 - 200 Nos 1 Job ₹ 15,68,000.00 19.3 No of OHT above 200Nos 1 Job ₹ 21,92,000.00 AMC of SCADA Software & Hardware System Annual Maintenance charges of Hardware & Soft ware supplied including remote communication hardaware at Site, Hardware at MCC, Cloud server maintenance, Data Analytics, SCADA Software, Reporting software sevices, Monthly SIMCARD communication chages including trouble shooting and modification as per 20 requirement. a) Periodic Maintenance Visit- 3 times in a year (5 Man-Days per Visit) b) Emergency Maintenance Visit - 2 times in a year (5 Man-Days per Visit) c) Software Modification - 2 times in a year (3 man- days per call) d) Maintenance Over Call - 3 Time in a year (2 man- days per call) 20.1 No of OHT up to 50 Nos 1 Job ₹ 20,24,000.00 20.2 No. of OHT between 50 - 200 Nos 1 Job ₹ 40,48,000.00 20.3 No of OHT above 200Nos 1 Job ₹ 60,72,000.00 Sr Item Description Qty Unit Rates No. 21 Web Client Software for Remote Monitoring 21.1 Single User 1No ₹ 2,18,475.00 21.2 Double User 1No ₹ 4,36,837.50 22 RF Trans - Receiver 01 No ₹ 72,900.00 MEASURING DEVICES MEASURING DEVICES 4 RateEach11,90,135.00

Pricing pumps against a live tender

Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.