Madhya Pradesh SOR 2023
M.S. Pipes, Specials, Fittings including Fabrication & Laying rates
75 m.s. pipes, specials, fittings including fabrication & laying items from the Madhya Pradesh Public Health Engineering Department (PHED), effective 2023-09-01.
M.S. Pipes, Specials, Fittings including Fabrication & Laying rates in the Madhya Pradesh Unified Schedule of Rates 2023 run from ₹2.00 to ₹84,947.00. Transcribed from Madhya Pradesh PHED — Unified Schedule of Rates for Water Supply, Sewerage and Allied Works, in force from 1 September 2023. Reference only — verify against the official source before pricing a bid.
75 items — scroll the table to browse
| Description | Unit | ||
|---|---|---|---|
| 5.1.8.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 450 mm (I.D) Thickness of pipe10 mm | Metre | 11,190.00 |
| 5.1.9.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 500 mm (I.D) Thickness of pipe10 mm | Metre | 11,442.00 |
| 5.1.10.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 550 mm (I.D) Thickness of pipe10 mm | Metre | 12,596.00 |
| 5.1.10.5 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 550 mm (I.D) Thickness of pipe12 mm | Metre | 15,225.00 |
| 5.1.11.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 600 mm (I.D) Thickness of pipe10 mm | Metre | 13,668.00 |
| 5.1.11.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 600 mm (I.D) Thickness of pipe12 mm | Metre | 16,516.00 |
| 5.1.12.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 650 mm (I.D) Thickness of pipe10 mm | Metre | 14,807.00 |
| 5.1.12.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 650 mm (I.D) Thickness of pipe12 mm | Metre | 17,888.00 |
| 5.1.13.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 700 mm (I.D) Thickness of pipe10 mm | Metre | 15,929.00 |
| 5.1.13.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 700 mm (I.D) Thickness of pipe12 mm | Metre | 19,238.00 |
| 5.1.13.5 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 700 mm (I.D) Thickness of pipe14 mm | Metre | 22,412.00 |
| 5.1.14.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 750 mm (I.D) Thickness of pipe7 mm Sr. No. Description of Item Unit Rate | Metre | 11,814.00 |
| 5.1.14.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 750 mm (I.D) Thickness of pipe10 mm | Metre | 17,029.00 |
| 5.1.14.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 750 mm (I.D) Thickness of pipe12 mm | Metre | 20,563.00 |
| 5.1.15.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 800 mm (I.D) Thickness of pipe10 mm | Metre | 18,149.00 |
| 5.1.15.4 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 800 mm (I.D) Thickness of pipe12 mm | Metre | 21,912.00 |
| 5.1.16.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 850 mm (I.D) Thickness of pipe10 mm | Metre | 19,072.00 |
| 5.1.16.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 850 mm (I.D) Thickness of pipe12 mm | Metre | 23,024.00 |
| 5.1.17.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 900 mm (I.D) Thickness of pipe10 mm | Metre | 20,155.00 |
| 5.1.17.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 900 mm (I.D) Thickness of pipe12 mm | Metre | 24,328.00 |
| 5.1.18.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 950 mm (I.D) Thickness of pipe10 mm | Metre | 21,262.00 |
| 5.1.18.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 950 mm (I.D) Thickness of pipe12 mm | Metre | 25,661.00 |
| 5.1.19.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1000 mm (I.D) Thickness of pipe10 mm | Metre | 22,427.00 |
| 5.1.19.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1000 mm (I.D) Thickness of pipe12 mm | Metre | 27,065.00 |
| 5.1.20.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1050 mm (I.D) Thickness of pipe10 mm | Metre | 23,537.00 |
| 5.1.20.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1050 mm (I.D) Thickness of pipe12 mm | Metre | 28,402.00 |
| 5.1.21.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1100 mm (I.D) Thickness of pipe10 mm | Metre | 24,361.00 |
| 5.1.21.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1100 mm (I.D) Thickness of pipe12 mm | Metre | 29,395.00 |
| 5.1.22.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1150 mm (I.D) Thickness of pipe10 mm | Metre | 25,458.00 |
| 5.1.22.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1150 mm (I.D) Thickness of pipe12 mm | Metre | 30,716.00 |
| 5.1.23.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1200 mm (I.D) Thickness of pipe10 mm | Metre | 26,521.00 |
| 5.1.23.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1200 mm (I.D) Thickness of pipe12 mm | Metre | 31,996.00 |
| 5.1.24.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1250 mm (I.D) Thickness of pipe10 mm | Metre | 27,761.00 |
| 5.1.24.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1250 mm (I.D) Thickness of pipe12 mm | Metre | 33,489.00 |
| 5.1.26.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1350 mm (I.D) Thickness of pipe10 mm Sr. No. Description of Item Unit Rate | Metre | 29,770.00 |
| 5.1.26.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1350 mm (I.D) Thickness of pipe12 mm | Metre | 35,909.00 |
| 5.1.27.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1400 mm (I.D) Thickness of pipe12 mm | Metre | 35,285.00 |
| 5.1.27.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1400 mm (I.D) Thickness of pipe14 mm | Metre | 41,036.00 |
| 5.1.28.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1450 mm (I.D) Thickness of pipe12 mm | Metre | 36,484.00 |
| 5.1.28.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1450 mm (I.D) Thickness of pipe14 mm | Metre | 42,428.00 |
| 5.1.29.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1500 mm (I.D) Thickness of pipe12 mm | Metre | 38,148.00 |
| 5.1.29.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1500 mm (I.D) Thickness of pipe14 mm | Metre | 44,362.00 |
| 5.1.30.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1550 mm (I.D) Thickness of pipe12 mm | Metre | 39,355.00 |
| 5.1.30.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1550 mm (I.D) Thickness of pipe14 mm | Metre | 45,765.00 |
| 5.1.31.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1600 mm (I.D) Thickness of pipe14 mm | Metre | 49,105.00 |
| 5.1.31.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1600 mm (I.D) Thickness of pipe16 mm | Metre | 56,004.00 |
| 5.1.32.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1650 mm (I.D) Thickness of pipe14 mm | Metre | 53,962.00 |
| 5.1.32.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1650 mm (I.D) Thickness of pipe16 mm | Metre | 61,555.00 |
| 5.1.32.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1650 mm (I.D) Thickness of pipe18 mm | Metre | 69,166.00 |
| 5.1.33.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1700 mm (I.D) Thickness of pipe14 mm | Metre | 52,147.00 |
| 5.1.33.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1700 mm (I.D) Thickness of pipe16 mm | Metre | 59,470.00 |
| 5.1.33.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1700 mm (I.D) Thickness of pipe18 mm | Metre | 66,810.00 |
| 5.1.34.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1750 mm (I.D) Thickness of pipe14 mm | Metre | 53,668.00 |
| 5.1.34.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1750 mm (I.D) Thickness of pipe16 mm | Metre | 61,202.00 |
| 5.1.34.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1750 mm (I.D) Thickness of pipe18 mm | Metre | 68,755.00 |
| 5.1.35.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1800 mm (I.D) Thickness of pipe14 mm | Metre | 55,189.00 |
| 5.1.35.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1800 mm (I.D) Thickness of pipe16 mm | Metre | 62,935.00 |
| 5.1.35.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1800 mm (I.D) Thickness of pipe18 mm | Metre | 70,699.00 |
| 5.1.36.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1850 mm (I.D) Thickness of pipe14 mm | Metre | 57,457.00 |
| 5.1.36.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1850 mm (I.D) Thickness of pipe16 mm | Metre | 65,523.00 |
| 5.1.36.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1850 mm (I.D) Thickness of pipe20 mm | Metre | 81,707.00 |
| 5.1.37.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1900 mm (I.D) Thickness of pipe16 mm | Metre | 66,400.00 |
| 5.1.37.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1900 mm (I.D) Thickness of pipe18 mm | Metre | 74,587.00 |
| 5.1.37.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1900 mm (I.D) Thickness of pipe20 mm | Metre | 82,792.00 |
| 5.1.38.1 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1950 mm (I.D) Thickness of pipe16 mm | Metre | 68,133.00 |
| 5.1.38.2 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1950 mm (I.D) Thickness of pipe18 mm | Metre | 76,532.00 |
| 5.1.38.3 | Manufacturing, supplying at site & laying, jointing of following M.S. pipes as per IS specifications, duly testing for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site and stacking etc. complete as per direction of Engineer-in-Charge. (Excluding protective coating) — Dia. of pipe 1950 mm (I.D) Thickness of pipe20 mm Sr. No. Description of Item Unit Rate Fabrication of M.S. Pipes and Specials | Metre | 84,947.00 |
| 5.2 | Fabrication of M.S. pipes & specials as per IS specifications with inside & outside epoxy coating as per relevant IS code, duly tested for usage in Drinking water inclusive of all materials, inspection charges, transit insurance, loading/unloading, FOR site, & stacking etc. complete as for direction of Engineer-in-Charge | KG | 93.00 |
| 5.3 | Labour only for lowering and laying of MS pipe and specials as per approved specification complete as directed by Engineer in Charge | KG | 2.00 |
| 5.4 | Providing and applying primer and one coat of red oxide externally | Sqm | 57.00 |
| 5.5 | Providing and applying primer and one coat of red oxide of iron paint, internally. Laying of M.S. Pipes and Specials | Sqm | 130.00 |
| 5.6.1.1 | Labour Only for lowering & laying of M.S. Pipes as per approved specification and as directed by Engineer in charge100 mm to 500 mm. dia | Metre | 80.00 |
| 5.6.2.1 | Labour Only for lowering & laying of M.S. Pipes as per approved specification and as directed by Engineer in charge — 10 mm to 12 mm thick400 mm to 7520 mm. dia | Metre | 207.00 |
| 5.7.4.4 | Providing rigid welded joint to the following MS Pipe including testing of joints and cost of jointing material as per relevant approve specification complete — Dia. of pipe 400 mm (I.D) Thickness of pipe10 mm | Metre | 493.00 |
| 5.7.5.4 | Providing rigid welded joint to the following MS Pipe including testing of joints and cost of jointing material as per relevant approve specification complete — Dia. of pipe 450 mm (I.D) Thickness of pipe10 mm 5.6.6 Dia. of pipe 500 mm (I.D) Thickness of pipe: 5.6.6.1 5 mm Meter 118.00 5.6.6.2 6 mm Meter 241.00 5.6.6.3 8 mm Meter 498.00 5.6.6.4 10 mm Meter 611.00 5.6.6.5 12 mm Meter 1098.00 5.6.7 Dia. of pipe 550 mm (I.D) Thickness of pipe: 5.6.7.1 5 mm Meter 130.00 5.6.7.2 6 mm Meter 264.00 5.6.7.3 8 mm Meter 546.00 5.6.7.4 10 mm Meter 669.00 5.6.7.5 12 mm Meter 1203.00 5.6.8 Dia. of pipe 600 mm (I.D) Thickness of pipe: 5.6.8.1 6 mm Meter 287.00 5.6.8.2 8 mm Meter 594.00 5.6.8.3 10 mm Meter 728.00 5.6.8.4 12 mm Meter 1308.00 5.6.9 Dia. of pipe 650 mm (I.D) Thickness of pipe: 5.6.9.1 6 mm Meter 311.00 5.6.9.2 8 mm Meter 643.00 5.6.9.3 10 mm Meter 787.00 5.6.9.4 12 mm Meter 1413.00 5.6.10 Dia. of pipe 700 mm (I.D) Thickness of pipe: 5.6.10.1 6 mm Meter 334.00 5.6.10.2 8 mm Meter 691.00 5.6.10.3 10 mm Meter 846.00 5.6.10.4 12 mm Meter 1517.00 5.6.10.5 14 mm Meter 1526.00 5.6.11 Dia. of pipe 750 mm (I.D) Thickness of pipe: 5.6.11.1 7 mm Meter 359.00 5.6.11.2 8 mm Meter 739.00 5.6.11.3 10 mm Meter 904.00 Sr. No. Description of Item Unit Rate 5.6.11.4 12 mm Meter 1622.00 5.6.12 Dia. of pipe 800 mm (I.D) Thickness of pipe: 5.6.12.1 7 mm Meter 382.00 5.6.12.2 8 mm Meter 787.00 5.6.12.3 10 mm Meter 963.00 5.6.12.4 12 mm Meter 1727.00 5.6.13 Dia. of pipe 850 mm (I.D) Thickness of pipe: 5.6.13.1 8 mm Meter 820.00 5.6.13.2 10 mm Meter 1017.00 5.6.13.3 12 mm Meter 1823.00 5.6.14 Dia. of pipe 900 mm (I.D) Thickness of pipe: 5.6.14.1 8 mm Meter 868.00 5.6.14.2 10 mm Meter 1076.00 5.6.14.3 12 mm Meter 1928.00 5.6.15 Dia. of pipe 950 mm (I.D) Thickness of pipe: 5.6.15.1 8 mm Meter 868.00 5.6.15.2 10 mm Meter 1076.00 5.6.15.3 12 mm Meter 1928.00 5.6.16 Dia. of pipe 1000 mm (I.D) Thickness of pipe: 5.6.16.1 8 mm Meter 980.00 5.6.16.2 10 mm Meter 1198.00 5.6.16.3 12 mm Meter 2146.00 5.6.17 Dia. of pipe 1050 mm (I.D) Thickness of pipe: 5.6.17.1 8 mm Meter 1028.00 5.6.17.2 10 mm Meter 1257.00 5.6.17.3 12 mm Meter 2251.00 5.6.18 Dia. of pipe 1100 mm (I.D) Thickness of pipe: 5.6.18.1 10 mm Meter 1315.00 5.6.18.2 12 mm Meter 2356.00 5.6.19 Dia. of pipe 1150 mm (I.D) Thickness of pipe: 5.6.19.1 10 mm Meter 1374.00 5.6.19.2 12 mm Meter 2460.00 5.6.20 Dia. of pipe 1200 mm (I.D) Thickness of pipe: 5.6.20.1 10 mm Meter 1433.00 5.6.20.2 12 mm Meter 2565.00 5.6.21 Dia. of pipe 1250 mm (I.D) Thickness of pipe: 5.6.21.1 10 mm Meter 1491.00 5.6.21.2 12 mm Meter 2670.00 5.6.22 Dia. of pipe 1300 mm (I.D) Thickness of pipe: 5.6.22.1 10 mm Meter 1550.00 5.6.22.2 12 mm Meter 2775.00 5.6.23 Dia. of pipe 1350 mm (I.D) Thickness of pipe: 5.6.23.1 10 mm Meter 1609.00 5.6.23.2 12 mm Meter 2880.00 5.6.24 Dia. of pipe 1400 mm (I.D) Thickness of pipe: Sr. No. Description of Item Unit Rate 5.6.24.1 12 mm Meter 2976.00 5.6.24.2 14 mm Meter 2984.00 5.6.25 Dia. of pipe 1450 mm (I.D) Thickness of pipe: 5.6.25.1 12 mm Meter 3081.00 5.6.25.2 14 mm Meter 3089.00 5.6.26 Dia. of pipe 1500 mm (I.D) Thickness of pipe: 5.6.26.1 12 mm Meter 3185.00 5.6.26.2 14 mm Meter 3194.00 5.6.27 Dia. of pipe 1550 mm (I.D) Thickness of pipe: 5.6.27.1 12 mm Meter 3290.00 5.6.27.2 14 mm Meter 3299.00 5.6.28 Dia. of pipe 1600 mm (I.D) Thickness of pipe: 5.6.28.1 14 mm Meter 3395.00 5.6.28.2 16 mm Meter 3403.00 5.6.29 Dia. of pipe 1650 mm (I.D) Thickness of pipe: 5.6.29.1 14 mm Meter 3525.00 5.6.29.2 16 mm Meter 3533.00 5.6.29.3 18 mm Meter 3592.00 5.6.30 Dia. of pipe 1700 mm (I.D) Thickness of pipe: 5.6.30.1 14 mm Meter 3630.00 5.6.30.2 16 mm Meter 3638.00 5.6.30.3 18 mm Meter 3697.00 5.6.31 Dia. of pipe 1750 mm (I.D) Thickness of pipe: 5.6.31.1 14 mm Meter 3735.00 5.6.31.2 16 mm Meter 3743.00 5.6.31.3 18 mm Meter 3802.00 5.6.32 Dia. of pipe 1800 mm (I.D) Thickness of pipe: 5.6.32.1 14 mm Meter 3839.00 5.6.32.2 16 mm Meter 3848.00 5.6.32.3 18 mm Meter 3906.00 5.6.33 Dia. of pipe 1850 mm (I.D) Thickness of pipe: 5.6.33.1 14 mm Meter 3944.00 5.6.33.2 16 mm Meter 3953.00 5.6.33.3 20 mm Meter 4011.00 5.6.34 Dia. of pipe 1900 mm (I.D) Thickness of pipe: 5.6.34.1 16 mm Meter 4049.00 5.6.34.2 18 mm Meter 4057.00 5.6.34.3 20 mm Meter 4116.00 5.6.35 Dia. of pipe 1950 mm (I.D) Thickness of pipe: 5.6.35.1 16 mm Meter 4154.00 5.6.35.2 18 mm Meter 4162.00 5.6.35.3 20 mm Meter 4170.00 5.6.36 Dia. of pipe 2000 mm (I.D) Thickness of pipe: 5.6.36.1 16 mm Meter 4258.00 5.6.36.3 20 mm Meter 4275.00 Sr. No. Description of Item Unit Rate 5.7 Providing & applying 30 mm thick 1:3 cement mortar coating outside face of M S pipe as per relevant IS specification including testing along with fixing of Sqm 656.00 (100 x 3 mm) wire mesh as per approved specification per Sqm | Metre | 552.00 |
Other chapters in this schedule
- Ductile Iron Pressure Pipes and Specials with Tyton Joints and DI Valve (669)
- Polyethylene Pipe and Fittings (209)
- Galvanized Iron Pipes, Specials and Gun Metal or Brass Fittings (354)
- Oriented P.V.C. (PVC-O) Pipes (13)
- Asbestos Cement Pressure Pipes and Cast Iron Fittings (16)
- Bar Wrapped Steel Cylinder Pipes (BWSC) (270)
- Cast Iron Socket and Spigot Pipes & Specials with Lead Joints, Tyton Joints, Cast Iron Pipes & Specials with Flanged Joints, Cast Iron Valves, Sluice Gate & Air Valves (351)
- Consumer Service Connection (131)
- Water Hammer Devices (96)
- Pumps (172)
- Measuring Devices (40)
- Miscellaneous (Water Supply) (73)
- Allied Civil Works (82)
- Intake Well Related Works (27)
- Ground Service Reservoir & Sump Tanks (GSR) (19)
- Construction of Gravel Packed Tube Well (5)
- Development, Yield Test and Disinfection of Tube Well (6)
- Unplasticized Non-Pressure Polyvinyl Chloride (PVC-U) Pipes, Double Wall Corrugated (DWC) Pipes for Use in Underground Sewerage System (32)
- Reinforced Cement Concrete Pipes (190)
- Salt Glazed Stoneware Pipes, Sewer Appurtenances & Sewerage Maintenance (126)
Pricing m.s. pipes, specials, fittings including fabrication & laying against a live tender
Mapping a tender BOQ to the right schedule items, applying the current cost index, and catching where rates have moved since the base edition is slow and easy to get wrong. Arched's estimation engine reads the tender, maps it to the applicable schedule, and flags where the numbers are exposed before submission.
See how estimation works